Search criteria
34 vulnerabilities found for GateManager by Secomea
CVE-2021-32007 (GCVE-0-2021-32007)
Vulnerability from cvelistv5 – Published: 2024-12-13 11:05 – Updated: 2024-12-23 19:14
VLAI?
Title
Missing security header: Referrer-Policy URL
Summary
This issue affects:
Secomea GateManager
Version 9.5 and all prior versions.
Protection Mechanism Failure vulnerability in web server of Secomea GateManager to potentially leak information to remote servers.
Severity ?
CWE
- CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
0 , ≤ 9.5
(custom)
|
Credits
Regel Partners B.V.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2021-32007",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-23T19:14:40.946759Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-23T19:14:49.546Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Regel Partners B.V."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This issue affects:\u003cbr\u003eSecomea GateManager\u003cbr\u003eVersion 9.5 and all prior versions.\u003cbr\u003eProtection Mechanism Failure vulnerability in web server of Secomea GateManager to potentially leak information to remote servers."
}
],
"value": "This issue affects:\nSecomea GateManager\nVersion 9.5 and all prior versions.\nProtection Mechanism Failure vulnerability in web server of Secomea GateManager to potentially leak information to remote servers."
}
],
"impacts": [
{
"capecId": "CAPEC-116",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-116 Excavation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:L/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-13T11:05:58.370Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Missing security header: Referrer-Policy URL",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32007",
"datePublished": "2024-12-13T11:05:58.370Z",
"dateReserved": "2021-05-03T16:28:23.358Z",
"dateUpdated": "2024-12-23T19:14:49.546Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-1969 (GCVE-0-2024-1969)
Vulnerability from cvelistv5 – Published: 2024-04-29 13:29 – Updated: 2024-08-01 18:56
VLAI?
Title
Heap buffer overflow
Summary
Buffer Copy without Checking Size of Input ('Classic Buffer Overflow') vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.This issue affects GateManager: from 9.7 before 11.2.624095033.
Severity ?
8.2 (High)
CWE
- CWE-120 - Buffer Copy without Checking Size of Input ('Classic Buffer Overflow')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
9.7 , < 11.2.624095033
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:secomea:gatemanager:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gatemanager",
"vendor": "secomea",
"versions": [
{
"status": "affected",
"version": "9.7"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1969",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-29T15:12:46.757035Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T18:00:05.549Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:56:22.773Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"webserver"
],
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "11.2.624095033",
"status": "affected",
"version": "9.7",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.\u003cp\u003eThis issue affects GateManager: from 9.7 before 11.2.624095033.\u003c/p\u003e"
}
],
"value": "Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027) vulnerability in Secomea GateManager (webserver modules) allows crash of GateManager.This issue affects GateManager: from 9.7 before 11.2.624095033.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-120",
"description": "CWE-120 Buffer Copy without Checking Size of Input (\u0027Classic Buffer Overflow\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-29T13:29:01.094Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-6718"
],
"discovery": "INTERNAL"
},
"title": "Heap buffer overflow",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2024-1969",
"datePublished": "2024-04-29T13:29:01.094Z",
"dateReserved": "2024-02-28T14:49:31.001Z",
"dateUpdated": "2024-08-01T18:56:22.773Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2024-1579 (GCVE-0-2024-1579)
Vulnerability from cvelistv5 – Published: 2024-04-29 13:27 – Updated: 2024-08-01 18:40
VLAI?
Title
Insufficient seeding of random number generator
Summary
Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG) vulnerability in Secomea GateManager (Webserver modules) allows Session Hijacking.This issue affects GateManager: before 11.2.624071020.
Severity ?
8.1 (High)
CWE
- CWE-335 - Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
0 , < 11.2.624071020
(custom)
|
Credits
Researchers at Paderborn University and Ruhr University Bochum
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:secomea:gatemanager:-:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "gatemanager",
"vendor": "secomea",
"versions": [
{
"lessThan": "11.2.62.4971020",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-1579",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-04-29T14:34:13.948903Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-04T17:59:30.225Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-01T18:40:21.431Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Webserver"
],
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "11.2.624071020",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Researchers at Paderborn University and Ruhr University Bochum"
}
],
"datePublic": "2024-04-29T13:21:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG) vulnerability in Secomea GateManager (Webserver modules) allows Session Hijacking.\u003cp\u003eThis issue affects GateManager: before 11.2.624071020.\u003c/p\u003e"
}
],
"value": "Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG) vulnerability in Secomea GateManager (Webserver modules) allows Session Hijacking.This issue affects GateManager: before 11.2.624071020.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-593",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-593 Session Hijacking"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-335",
"description": "CWE-335 Incorrect Usage of Seeds in Pseudo-Random Number Generator (PRNG)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-29T13:27:55.045Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-6690"
],
"discovery": "EXTERNAL"
},
"title": "Insufficient seeding of random number generator",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2024-1579",
"datePublished": "2024-04-29T13:27:55.045Z",
"dateReserved": "2024-02-16T12:11:01.147Z",
"dateUpdated": "2024-08-01T18:40:21.431Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-3675 (GCVE-0-2023-3675)
Vulnerability from cvelistv5 – Published: 2024-04-18 10:41 – Updated: 2024-08-21 14:08
VLAI?
Title
Insufficient input validation when downloading certain file types.
Summary
Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal') vulnerability in Secomea GateManager (Web GUI) allows Reading Data from System Resources.This issue affects GateManager: from 11.0.623074018 before 11.0.623373051.
Severity ?
6.5 (Medium)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
11.0.623074018 , < 11.0.623373051
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T07:01:57.508Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2023-3675",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-08-21T14:08:31.273757Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-08-21T14:08:41.868Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Web GUI"
],
"platforms": [
"Linux"
],
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "11.0.623373051",
"status": "affected",
"version": "11.0.623074018",
"versionType": "custom"
}
]
}
],
"datePublic": "2024-04-18T10:40:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Secomea GateManager (Web GUI) allows Reading Data from System Resources.\u003cp\u003eThis issue affects GateManager: from 11.0.623074018 before 11.0.623373051.\u003c/p\u003e"
}
],
"value": "Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027) vulnerability in Secomea GateManager (Web GUI) allows Reading Data from System Resources.This issue affects GateManager: from 11.0.623074018 before 11.0.623373051.\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-545",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-545 Pull Data from System Resources"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 6.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-04-18T10:41:32.348Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-6533"
],
"discovery": "INTERNAL"
},
"title": "Insufficient input validation when downloading certain file types.",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2023-3675",
"datePublished": "2024-04-18T10:41:25.088Z",
"dateReserved": "2023-07-14T12:57:35.931Z",
"dateUpdated": "2024-08-21T14:08:41.868Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2023-0317 (GCVE-0-2023-0317)
Vulnerability from cvelistv5 – Published: 2023-04-19 11:57 – Updated: 2025-02-05 15:03
VLAI?
Title
GateManager debug interface is included in non-debug builds
Summary
Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information.
Severity ?
4.9 (Medium)
CWE
- CWE-420 - Unprotected Alternate Channel
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
10.0 , < 10.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T05:10:55.186Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-0317",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T15:02:04.508680Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-420",
"description": "CWE-420 Unprotected Alternate Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T15:03:03.498Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "10.1",
"status": "affected",
"version": "10.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-19T11:57:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information."
}
],
"value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information."
}
],
"impacts": [
{
"capecId": "CAPEC-383",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-383 Harvesting Information via API Event Monitoring"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-420",
"description": "CWE-420 Unprotected Alternate Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-19T11:57:46.409Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "GateManager debug interface is included in non-debug builds",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2023-0317",
"datePublished": "2023-04-19T11:57:46.409Z",
"dateReserved": "2023-01-16T09:36:00.479Z",
"dateUpdated": "2025-02-05T15:03:03.498Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-4308 (GCVE-0-2022-4308)
Vulnerability from cvelistv5 – Published: 2023-04-19 11:56 – Updated: 2025-02-05 15:05
VLAI?
Title
Clear-text passwords in configuration files
Summary
Plaintext Storage of a Password vulnerability in Secomea GateManager (USB wizard) allows Authentication abuse on SiteManager, if the generated file is leaked.
Severity ?
6.1 (Medium)
CWE
- CWE-256 - Plaintext Storage of a Password
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
5.0 , < 10.1
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T01:34:50.085Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2022-4308",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-02-05T15:04:01.779043Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-02-05T15:05:16.492Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"USB wizard"
],
"platforms": [
"Linux"
],
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "10.1",
"status": "affected",
"version": "5.0",
"versionType": "custom"
}
]
}
],
"datePublic": "2023-04-19T11:51:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Plaintext Storage of a Password vulnerability in Secomea GateManager (USB wizard) allows Authentication abuse on SiteManager, if the generated file is leaked."
}
],
"value": "Plaintext Storage of a Password vulnerability in Secomea GateManager (USB wizard) allows Authentication abuse on SiteManager, if the generated file is leaked."
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.1,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-256",
"description": "CWE-256 Plaintext Storage of a Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-19T11:56:55.106Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"discovery": "INTERNAL"
},
"title": "Clear-text passwords in configuration files",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-4308",
"datePublished": "2023-04-19T11:56:32.348Z",
"dateReserved": "2022-12-06T13:33:10.501Z",
"dateUpdated": "2025-02-05T15:05:16.492Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-2752 (GCVE-0-2022-2752)
Vulnerability from cvelistv5 – Published: 2022-12-09 13:30 – Updated: 2025-04-22 19:44
VLAI?
Title
Potential vulnerabilities in GM login process
Summary
A vulnerability in the web server of Secomea GateManager allows a local user to impersonate as the previous user under some failed login conditions.
This issue affects:
Secomea GateManager versions from 9.4 through 9.7.
Severity ?
5.5 (Medium)
CWE
- CWE-287 - Improper Authentication
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
9.4 , < 10.0
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:46:04.419Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-2752",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-22T19:44:26.372042Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-22T19:44:33.832Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "10.0",
"status": "affected",
"version": "9.4",
"versionType": "custom"
}
]
}
],
"datePublic": "2022-12-09T11:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eA vulnerability in the web server of Secomea GateManager allows a local user to impersonate as the previous user under some failed login conditions.\u003c/div\u003e\u003cdiv\u003eThis issue affects:\u003c/div\u003e\u003cdiv\u003eSecomea GateManager versions from 9.4 through 9.7.\u003c/div\u003e\u003cbr\u003e"
}
],
"value": "A vulnerability in the web server of Secomea GateManager allows a local user to impersonate as the previous user under some failed login conditions.\n\nThis issue affects:\n\nSecomea GateManager versions from 9.4 through 9.7.\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-114",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-114 Authentication Abuse"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:L/UI:R/S:U/C:L/I:H/A:L",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-287",
"description": "CWE-287 Improper Authentication",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-09T13:30:26.346Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-5896"
],
"discovery": "EXTERNAL"
},
"title": "Potential vulnerabilities in GM login process",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-2752",
"datePublished": "2022-12-09T13:30:26.346Z",
"dateReserved": "2022-08-10T09:43:33.129Z",
"dateUpdated": "2025-04-22T19:44:33.832Z",
"requesterUserId": "44bd1e71-3702-434c-b36b-c1ac3bb0bab6",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-38123 (GCVE-0-2022-38123)
Vulnerability from cvelistv5 – Published: 2022-12-06 15:58 – Updated: 2025-04-23 16:12
VLAI?
Title
Insufficient validation of plugin files
Summary
Improper Input Validation of plugin files in Administrator Interface of Secomea GateManager allows a server administrator to inject code into the GateManager interface.
This issue affects:
Secomea GateManager
versions prior to 10.0.
Severity ?
8.7 (High)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
0 , < 10.0
("custom")
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T10:45:52.623Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2022-38123",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T16:12:26.690794Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-04-23T16:12:37.744Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "10.0",
"status": "affected",
"version": "0",
"versionType": "\"custom\""
}
]
}
],
"datePublic": "2022-12-05T23:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cdiv\u003eImproper Input Validation of plugin files in Administrator Interface of Secomea GateManager allows a server administrator to inject code into the GateManager interface.\u003c/div\u003e\u003cdiv\u003eThis issue affects:\u003c/div\u003e\u003cdiv\u003eSecomea GateManager\u003c/div\u003e\u003cdiv\u003eversions prior to 10.0.\u003c/div\u003e\u003cp\u003e\u003c/p\u003e"
}
],
"value": "Improper Input Validation of plugin files in Administrator Interface of Secomea GateManager allows a server administrator to inject code into the GateManager interface.\n\nThis issue affects:\n\nSecomea GateManager\n\nversions prior to 10.0.\n\n\n\n"
}
],
"impacts": [
{
"capecId": "CAPEC-242",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-242 Code Injection"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.7,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-12-06T15:59:52.408Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5851"
],
"discovery": "EXTERNAL"
},
"title": "Insufficient validation of plugin files",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-38123",
"datePublished": "2022-12-06T15:58:01.365Z",
"dateReserved": "2022-08-10T09:46:05.632Z",
"dateUpdated": "2025-04-23T16:12:37.744Z",
"requesterUserId": "44bd1e71-3702-434c-b36b-c1ac3bb0bab6",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25786 (GCVE-0-2022-25786)
Vulnerability from cvelistv5 – Published: 2022-05-04 17:17 – Updated: 2024-08-03 04:49
VLAI?
Title
GateManager debug interface is included in production builds
Summary
Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information. This issue affects: GateManager all versions prior to 9.7.
Severity ?
4.9 (Medium)
CWE
- CWE-420 - Unprotected Alternate Channel
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.267Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information. This issue affects: GateManager all versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-420",
"description": "CWE-420 Unprotected Alternate Channel",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T17:17:34.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5457"
],
"discovery": "INTERNAL"
},
"title": "GateManager debug interface is included in production builds",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25786",
"STATE": "PUBLIC",
"TITLE": "GateManager debug interface is included in production builds"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Unprotected Alternate Channel vulnerability in debug console of GateManager allows system administrator to obtain sensitive information. This issue affects: GateManager all versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-420 Unprotected Alternate Channel"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5457"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25786",
"datePublished": "2022-05-04T17:17:34.000Z",
"dateReserved": "2022-02-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:49:43.267Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25787 (GCVE-0-2022-25787)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:58 – Updated: 2024-08-03 04:49
VLAI?
Title
GTA URLs issued by LMM WEB API may leak information
Summary
Information Exposure Through Query Strings in GET Request vulnerability in LMM API of Secomea GateManager allows system administrator to hijack connection. This issue affects: Secomea GateManager all versions prior to 9.7.
Severity ?
7.5 (High)
CWE
- CWE-598 - Information Exposure Through Query Strings in GET Request
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.776Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Information Exposure Through Query Strings in GET Request vulnerability in LMM API of Secomea GateManager allows system administrator to hijack connection. This issue affects: Secomea GateManager all versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-598",
"description": "CWE-598 Information Exposure Through Query Strings in GET Request",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:58:45.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5523"
],
"discovery": "INTERNAL"
},
"title": "GTA URLs issued by LMM WEB API may leak information",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25787",
"STATE": "PUBLIC",
"TITLE": "GTA URLs issued by LMM WEB API may leak information"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Information Exposure Through Query Strings in GET Request vulnerability in LMM API of Secomea GateManager allows system administrator to hijack connection. This issue affects: Secomea GateManager all versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-598 Information Exposure Through Query Strings in GET Request"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5523"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25787",
"datePublished": "2022-05-04T13:58:45.000Z",
"dateReserved": "2022-02-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:49:43.776Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25783 (GCVE-0-2022-25783)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:55 – Updated: 2024-08-03 04:49
VLAI?
Title
Hacking attempts from logged-in users are not properly logged by GM
Summary
Insufficient Logging vulnerability in web server of Secomea GateManager allows logged in user to issue improper queries without logging. This issue affects: Secomea GateManager versions prior to 9.7.
Severity ?
4.3 (Medium)
CWE
- CWE-778 - Insufficient Logging
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.230Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Insufficient Logging vulnerability in web server of Secomea GateManager allows logged in user to issue improper queries without logging. This issue affects: Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-778",
"description": "CWE-778 Insufficient Logging",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:55:13.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5355"
],
"discovery": "INTERNAL"
},
"title": "Hacking attempts from logged-in users are not properly logged by GM",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25783",
"STATE": "PUBLIC",
"TITLE": "Hacking attempts from logged-in users are not properly logged by GM"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Insufficient Logging vulnerability in web server of Secomea GateManager allows logged in user to issue improper queries without logging. This issue affects: Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-778 Insufficient Logging"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5355"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25783",
"datePublished": "2022-05-04T13:55:13.000Z",
"dateReserved": "2022-02-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:49:43.230Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25782 (GCVE-0-2022-25782)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:54 – Updated: 2024-08-03 04:49
VLAI?
Title
Insufficient privilege checks on object access and updates.
Summary
Improper Handling of Insufficient Privileges vulnerability in Web UI of Secomea GateManager allows logged in user to access and update privileged information. This issue affects: Secomea GateManager versions prior to 9.7.
Severity ?
5.4 (Medium)
CWE
- CWE-274 - Improper Handling of Insufficient Privileges
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.231Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Improper Handling of Insufficient Privileges vulnerability in Web UI of Secomea GateManager allows logged in user to access and update privileged information. This issue affects: Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-274",
"description": "CWE-274 Improper Handling of Insufficient Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:54:16.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5335"
],
"discovery": "INTERNAL"
},
"title": "Insufficient privilege checks on object access and updates.",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25782",
"STATE": "PUBLIC",
"TITLE": "Insufficient privilege checks on object access and updates."
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Handling of Insufficient Privileges vulnerability in Web UI of Secomea GateManager allows logged in user to access and update privileged information. This issue affects: Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-274 Improper Handling of Insufficient Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5335"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25782",
"datePublished": "2022-05-04T13:54:16.000Z",
"dateReserved": "2022-02-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:49:43.231Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25781 (GCVE-0-2022-25781)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:53 – Updated: 2024-08-03 04:49
VLAI?
Title
Reflected XSS issues in GateManager
Summary
Cross-site Scripting (XSS) vulnerability in Web UI of Secomea GateManager allows phishing attacker to inject javascript or html into logged in user session.
Severity ?
4.2 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.192Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in Web UI of Secomea GateManager allows phishing attacker to inject javascript or html into logged in user session."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:53:17.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5314"
],
"discovery": "INTERNAL"
},
"title": "Reflected XSS issues in GateManager",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25781",
"STATE": "PUBLIC",
"TITLE": "Reflected XSS issues in GateManager"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site Scripting (XSS) vulnerability in Web UI of Secomea GateManager allows phishing attacker to inject javascript or html into logged in user session."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5314"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25781",
"datePublished": "2022-05-04T13:53:17.000Z",
"dateReserved": "2022-02-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:49:43.192Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25780 (GCVE-0-2022-25780)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:52 – Updated: 2024-08-03 04:49
VLAI?
Title
Information leak via device availability query function
Summary
Information Exposure vulnerability in web UI of Secomea GateManager allows logged in user to query devices outside own scope.
Severity ?
4.3 (Medium)
CWE
- CWE-200 - Information Exposure
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.496Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Information Exposure vulnerability in web UI of Secomea GateManager allows logged in user to query devices outside own scope."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-200",
"description": "CWE-200 Information Exposure",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:52:15.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5310"
],
"discovery": "INTERNAL"
},
"title": "Information leak via device availability query function",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25780",
"STATE": "PUBLIC",
"TITLE": "Information leak via device availability query function"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Information Exposure vulnerability in web UI of Secomea GateManager allows logged in user to query devices outside own scope."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-200 Information Exposure"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5310"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25780",
"datePublished": "2022-05-04T13:52:15.000Z",
"dateReserved": "2022-02-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:49:43.496Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25779 (GCVE-0-2022-25779)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:51 – Updated: 2024-08-03 04:49
VLAI?
Title
Insufficient scope checks allows adding unrelated audit log entries
Summary
Logging of Excessive Data vulnerability in audit log of Secomea GateManager allows logged in user to write text entries in audit log. This issue affects: Secomea GateManager versions prior to 9.7.
Severity ?
4.3 (Medium)
CWE
- CWE-779 - Logging of Excessive Data
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.260Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Logging of Excessive Data vulnerability in audit log of Secomea GateManager allows logged in user to write text entries in audit log. This issue affects: Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-779",
"description": "CWE-779 Logging of Excessive Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:51:08.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5309"
],
"discovery": "INTERNAL"
},
"title": "Insufficient scope checks allows adding unrelated audit log entries",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25779",
"STATE": "PUBLIC",
"TITLE": "Insufficient scope checks allows adding unrelated audit log entries"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Logging of Excessive Data vulnerability in audit log of Secomea GateManager allows logged in user to write text entries in audit log. This issue affects: Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-779 Logging of Excessive Data"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5309"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25779",
"datePublished": "2022-05-04T13:51:08.000Z",
"dateReserved": "2022-02-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:49:43.260Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2022-25778 (GCVE-0-2022-25778)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:49 – Updated: 2024-08-03 04:49
VLAI?
Title
Unload handlers may unintentionally defeat CSRF guards
Summary
Cross-Site Request Forgery (CSRF) vulnerability in Web UI of Secomea GateManager allows phishing attacker to issue get request in logged in user session.
Severity ?
4.2 (Medium)
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
unspecified , < 9.7
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T04:49:43.681Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in Web UI of Secomea GateManager allows phishing attacker to issue get request in logged in user session."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:49:55.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5308"
],
"discovery": "INTERNAL"
},
"title": "Unload handlers may unintentionally defeat CSRF guards",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2022-25778",
"STATE": "PUBLIC",
"TITLE": "Unload handlers may unintentionally defeat CSRF guards"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in Web UI of Secomea GateManager allows phishing attacker to issue get request in logged in user session."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 4.2,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-352 Cross-Site Request Forgery (CSRF)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5308"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2022-25778",
"datePublished": "2022-05-04T13:49:55.000Z",
"dateReserved": "2022-02-22T00:00:00.000Z",
"dateUpdated": "2024-08-03T04:49:43.681Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32010 (GCVE-0-2021-32010)
Vulnerability from cvelistv5 – Published: 2022-05-04 13:45 – Updated: 2024-08-03 23:17
VLAI?
Title
Clients may connect to a GateManager with TLS 1.0
Summary
Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7.
Severity ?
5.6 (Medium)
CWE
- CWE-326 - Inadequate Encryption Strength
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Secomea | SiteManager |
Affected:
All , < 9.7
(custom)
|
||||||||||||
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.463Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SiteManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
},
{
"product": "LinkManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
},
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.7",
"status": "affected",
"version": "unspecified",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-326",
"description": "CWE-326 Inadequate Encryption Strength",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-05-04T13:45:03.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5699"
],
"discovery": "INTERNAL"
},
"title": "Clients may connect to a GateManager with TLS 1.0",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32010",
"STATE": "PUBLIC",
"TITLE": "Clients may connect to a GateManager with TLS 1.0"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SiteManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.7"
}
]
}
},
{
"product_name": "LinkManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
},
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_value": "9.7"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Inadequate Encryption Strength vulnerability in TLS stack of Secomea SiteManager, LinkManager, GateManager may facilitate man in the middle attacks. This issue affects: Secomea SiteManager All versions prior to 9.7. Secomea LinkManager versions prior to 9.7. Secomea GateManager versions prior to 9.7."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-326 Inadequate Encryption Strength"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5699"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32010",
"datePublished": "2022-05-04T13:45:03.000Z",
"dateReserved": "2021-05-03T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:17:28.463Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32009 (GCVE-0-2021-32009)
Vulnerability from cvelistv5 – Published: 2022-03-11 17:53 – Updated: 2024-08-03 23:17
VLAI?
Title
Missing XSS guards on firmware page
Summary
Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions.
Severity ?
5 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , ≤ 9.6.621421014
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.154Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.6.621421014",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-11T17:53:58.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-5196"
],
"discovery": "INTERNAL"
},
"title": "Missing XSS guards on firmware page",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32009",
"STATE": "PUBLIC",
"TITLE": "Missing XSS guards on firmware page"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "9.6.621421014"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site Scripting (XSS) vulnerability in firmware section of Secomea GateManager allows logged in user to inject javascript in browser session. This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
]
},
"source": {
"defect": [
"RD-5196"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32009",
"datePublished": "2022-03-11T17:53:58.000Z",
"dateReserved": "2021-05-03T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:17:28.154Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32006 (GCVE-0-2021-32006)
Vulnerability from cvelistv5 – Published: 2022-03-07 15:08 – Updated: 2024-08-03 23:17
VLAI?
Title
GateManager information leak for LinkManager Users
Summary
This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files.
Severity ?
5 (Medium)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , ≤ 9.6.621421014
(custom)
|
Credits
Schlumberger
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.226Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.6.621421014",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Schlumberger"
}
],
"descriptions": [
{
"lang": "en",
"value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-275",
"description": "CWE-275 Permission Issues",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-274",
"description": "CWE-274 Improper Handling of Insufficient Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-07T15:08:16.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-5018"
],
"discovery": "EXTERNAL"
},
"title": "GateManager information leak for LinkManager Users",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32006",
"STATE": "PUBLIC",
"TITLE": "GateManager information leak for LinkManager Users"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "9.6.621421014"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Schlumberger"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Permission Issues vulnerability in LinkManager web portal of Secomea GateManager allows logged in LinkManager user to access stored SiteManager backup files."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-275 Permission Issues"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-274 Improper Handling of Insufficient Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-5018"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32006",
"datePublished": "2022-03-07T15:08:16.000Z",
"dateReserved": "2021-05-03T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:17:28.226Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32008 (GCVE-0-2021-32008)
Vulnerability from cvelistv5 – Published: 2022-03-04 21:20 – Updated: 2024-08-03 23:17
VLAI?
Title
Logged-in Administrator may get unrestricted file system access
Summary
This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Improper Limitation of a Pathname to restricted directory, allows logged in GateManager admin to delete system Files or Directories.
Severity ?
9.9 (Critical)
CWE
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , ≤ 9.6.621421014
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:27.898Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThanOrEqual": "9.6.621421014",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Improper Limitation of a Pathname to restricted directory, allows logged in GateManager admin to delete system Files or Directories."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-552",
"description": "CWE-552 Files or Directories Accessible to External Parties",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-03-04T21:20:10.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
],
"source": {
"defect": [
"RD-5197"
],
"discovery": "INTERNAL"
},
"title": "Logged-in Administrator may get unrestricted file system access",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32008",
"STATE": "PUBLIC",
"TITLE": "Logged-in Administrator may get unrestricted file system access"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c=",
"version_name": "All",
"version_value": "9.6.621421014"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This issue affects: Secomea GateManager Version 9.6.621421014 and all prior versions. Improper Limitation of a Pathname to restricted directory, allows logged in GateManager admin to delete system Files or Directories."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-552 Files or Directories Accessible to External Parties"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory"
}
]
},
"source": {
"defect": [
"RD-5197"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32008",
"datePublished": "2022-03-04T21:20:10.000Z",
"dateReserved": "2021-05-03T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:17:27.898Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2021-32004 (GCVE-0-2021-32004)
Vulnerability from cvelistv5 – Published: 2021-11-22 20:32 – Updated: 2024-08-03 23:17
VLAI?
Title
GateManager does not enforce strict hostname matching for WEB server
Summary
This issue affects: Secomea GateManager All versions prior to 9.6. Improper Check of host header in web server of Secomea GateManager allows attacker to cause browser cache poisoning.
Severity ?
CWE
- CWE-923 - Improper Restriction of Communication Channel to Intended Endpoints
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , < 9.6
(custom)
|
Credits
Acunetix
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:17:28.501Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#4578"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.6",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Acunetix"
}
],
"descriptions": [
{
"lang": "en",
"value": "This issue affects: Secomea GateManager All versions prior to 9.6. Improper Check of host header in web server of Secomea GateManager allows attacker to cause browser cache poisoning."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-923",
"description": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-11-22T20:32:45.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#4578"
}
],
"source": {
"defect": [
"RD-4578"
],
"discovery": "EXTERNAL"
},
"title": "GateManager does not enforce strict hostname matching for WEB server",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2021-32004",
"STATE": "PUBLIC",
"TITLE": "GateManager does not enforce strict hostname matching for WEB server"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.6"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Acunetix"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This issue affects: Secomea GateManager All versions prior to 9.6. Improper Check of host header in web server of Secomea GateManager allows attacker to cause browser cache poisoning."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.7,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:N/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-923 Improper Restriction of Communication Channel to Intended Endpoints"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#4578",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#4578"
}
]
},
"source": {
"defect": [
"RD-4578"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2021-32004",
"datePublished": "2021-11-22T20:32:45.000Z",
"dateReserved": "2021-05-03T00:00:00.000Z",
"dateUpdated": "2024-08-03T23:17:28.501Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29030 (GCVE-0-2020-29030)
Vulnerability from cvelistv5 – Published: 2021-03-05 19:15 – Updated: 2024-09-17 00:31
VLAI?
Title
Insufficient CSRF guards
Summary
Cross-Site Request Forgery (CSRF) vulnerability in web GUI of Secomea GateManager allows an attacker to execute malicious code. This issue affects: Secomea GateManager All versions prior to 9.4.
Severity ?
8.1 (High)
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , < 9.4
(custom)
|
Credits
Schneider Electric
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.369Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.4",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Schneider Electric"
}
],
"datePublic": "2021-03-04T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in web GUI of Secomea GateManager allows an attacker to execute malicious code. This issue affects: Secomea GateManager All versions prior to 9.4."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-05T19:15:27.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-2417"
],
"discovery": "EXTERNAL"
},
"title": "Insufficient CSRF guards",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
"ID": "CVE-2020-29030",
"STATE": "PUBLIC",
"TITLE": "Insufficient CSRF guards"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.4"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Schneider Electric"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-Site Request Forgery (CSRF) vulnerability in web GUI of Secomea GateManager allows an attacker to execute malicious code. This issue affects: Secomea GateManager All versions prior to 9.4."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:N/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-352 Cross-Site Request Forgery (CSRF)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-2417"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29030",
"datePublished": "2021-03-05T19:15:27.247Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:31:38.842Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29028 (GCVE-0-2020-29028)
Vulnerability from cvelistv5 – Published: 2021-03-05 19:10 – Updated: 2024-09-17 00:10
VLAI?
Title
Reflected XSS issues
Summary
Cross-site Scripting (XSS) vulnerability in web GUI of Secomea GateManager allows an attacker to inject arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4.
Severity ?
6.3 (Medium)
CWE
- CWE-79 - Cross-site Scripting (XSS)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.4
(custom)
|
Credits
Tenable, Inc.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.757Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.4",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tenable, Inc."
}
],
"datePublic": "2021-03-04T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Cross-site Scripting (XSS) vulnerability in web GUI of Secomea GateManager allows an attacker to inject arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-05T19:10:00.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-3493"
],
"discovery": "EXTERNAL"
},
"title": "Reflected XSS issues",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
"ID": "CVE-2020-29028",
"STATE": "PUBLIC",
"TITLE": "Reflected XSS issues"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.4"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Tenable, Inc."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Cross-site Scripting (XSS) vulnerability in web GUI of Secomea GateManager allows an attacker to inject arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-3493"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29028",
"datePublished": "2021-03-05T19:10:00.326Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-09-17T00:10:29.690Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29029 (GCVE-0-2020-29029)
Vulnerability from cvelistv5 – Published: 2021-03-05 19:08 – Updated: 2024-09-16 22:31
VLAI?
Title
XSS issue due to insufficient sanitization of input field
Summary
Improper Input Validation, Cross-site Scripting (XSS) vulnerability in Web GUI of Secomea GateManager allows an attacker to execute arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4.
Severity ?
7.3 (High)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.4
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.576Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.4",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-03-04T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Improper Input Validation, Cross-site Scripting (XSS) vulnerability in Web GUI of Secomea GateManager allows an attacker to execute arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-79",
"description": "CWE-79 Cross-site Scripting (XSS)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-05T19:08:21.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
],
"source": {
"defect": [
"RD-3452"
],
"discovery": "INTERNAL"
},
"title": "XSS issue due to insufficient sanitization of input field",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
"ID": "CVE-2020-29029",
"STATE": "PUBLIC",
"TITLE": "XSS issue due to insufficient sanitization of input field"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.4"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Input Validation, Cross-site Scripting (XSS) vulnerability in Web GUI of Secomea GateManager allows an attacker to execute arbitrary javascript code. This issue affects: Secomea GateManager all versions prior to 9.4."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-20 Improper Input Validation"
}
]
},
{
"description": [
{
"lang": "eng",
"value": "CWE-79 Cross-site Scripting (XSS)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
}
]
},
"source": {
"defect": [
"RD-3452"
],
"discovery": "INTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29029",
"datePublished": "2021-03-05T19:08:21.917Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-09-16T22:31:25.557Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29032 (GCVE-0-2020-29032)
Vulnerability from cvelistv5 – Published: 2021-03-05 16:58 – Updated: 2024-09-16 16:32
VLAI?
Title
Add integrity check of GateManager firmware
Summary
Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022
Severity ?
8.4 (High)
CWE
- CWE-494 - Download of Code Without Integrity Check
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.4.621054022
(custom)
|
Credits
Tenable
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.434Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.tenable.com/security/research/tra-2021-06"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#3737"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.4.621054022",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Tenable"
}
],
"datePublic": "2021-03-04T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-494",
"description": "CWE-494 Download of Code Without Integrity Check",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-03-09T06:06:27.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.tenable.com/security/research/tra-2021-06"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#3737"
}
],
"source": {
"defect": [
"RD-3737"
],
"discovery": "EXTERNAL"
},
"title": "Add integrity check of GateManager firmware",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2021-03-04T22:00:00.000Z",
"ID": "CVE-2020-29032",
"STATE": "PUBLIC",
"TITLE": "Add integrity check of GateManager firmware"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.4.621054022"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Tenable"
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Upload of Code Without Integrity Check vulnerability in firmware archive of Secomea GateManager allows authenticated attacker to execute malicious code on server. This issue affects: Secomea GateManager all versions prior to 9.4.621054022"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.4,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-494 Download of Code Without Integrity Check"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.tenable.com/security/research/tra-2021-06",
"refsource": "MISC",
"url": "https://www.tenable.com/security/research/tra-2021-06"
},
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#3737",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#3737"
}
]
},
"source": {
"defect": [
"RD-3737"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29032",
"datePublished": "2021-03-05T16:58:27.148Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-09-16T16:32:33.185Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29023 (GCVE-0-2020-29023)
Vulnerability from cvelistv5 – Published: 2021-02-16 15:14 – Updated: 2024-09-17 04:24
VLAI?
Title
CSV Formula Injection possible due to improper fields escaping in GateManager
Summary
Improper Encoding or Escaping of Output from CSV Report Generator of Secomea GateManager allows an authenticated administrator to generate a CSV file that may run arbitrary commands on a victim's computer when opened in a spreadsheet program (like Excel). This issue affects: Secomea GateManager all versions prior to 9.3.
Severity ?
CWE
- CWE-116 - Improper Encoding or Escaping of Output
Assigner
References
| URL | Tags | |||||||
|---|---|---|---|---|---|---|---|---|
|
||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.570Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2418"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.3",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"datePublic": "2020-12-18T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Improper Encoding or Escaping of Output from CSV Report Generator of Secomea GateManager allows an authenticated administrator to generate a CSV file that may run arbitrary commands on a victim\u0027s computer when opened in a spreadsheet program (like Excel). This issue affects: Secomea GateManager all versions prior to 9.3."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-116",
"description": "CWE-116 Improper Encoding or Escaping of Output",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-16T15:14:57.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2418"
}
],
"source": {
"defect": [
"RD-2922"
],
"discovery": "EXTERNAL"
},
"title": "CSV Formula Injection possible due to improper fields escaping in GateManager",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2020-12-18T22:00:00.000Z",
"ID": "CVE-2020-29023",
"STATE": "PUBLIC",
"TITLE": "CSV Formula Injection possible due to improper fields escaping in GateManager"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.3"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Encoding or Escaping of Output from CSV Report Generator of Secomea GateManager allows an authenticated administrator to generate a CSV file that may run arbitrary commands on a victim\u0027s computer when opened in a spreadsheet program (like Excel). This issue affects: Secomea GateManager all versions prior to 9.3."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"baseSeverity": "LOW",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:U/C:L/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-116 Improper Encoding or Escaping of Output"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/"
},
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#2418",
"refsource": "CONFIRM",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2418"
}
]
},
"source": {
"defect": [
"RD-2922"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29023",
"datePublished": "2021-02-16T15:14:57.287Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-09-17T04:24:59.661Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29022 (GCVE-0-2020-29022)
Vulnerability from cvelistv5 – Published: 2021-02-16 15:08 – Updated: 2024-09-16 16:18
VLAI?
Title
Host Header Injection allowing web cache poisoning attacks
Summary
Failure to Sanitize host header value on output in the GateManager Web server could allow an attacker to conduct web cache poisoning attacks. This issue affects Secomea GateManager all versions prior to 9.3
Severity ?
5.3 (Medium)
CWE
- CWE-159 - Failure to Sanitize Special Element
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.436Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2923"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.3",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-02-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Failure to Sanitize host header value on output in the GateManager Web server could allow an attacker to conduct web cache poisoning attacks. This issue affects Secomea GateManager all versions prior to 9.3"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-159",
"description": "CWE-159 Failure to Sanitize Special Element",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-16T15:08:36.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2923"
}
],
"source": {
"defect": [
"RD-2923"
],
"discovery": "EXTERNAL"
},
"title": "Host Header Injection allowing web cache poisoning attacks",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2021-02-16T22:00:00.000Z",
"ID": "CVE-2020-29022",
"STATE": "PUBLIC",
"TITLE": "Host Header Injection allowing web cache poisoning attacks"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.3"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Failure to Sanitize host header value on output in the GateManager Web server could allow an attacker to conduct web cache poisoning attacks. This issue affects Secomea GateManager all versions prior to 9.3"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-159 Failure to Sanitize Special Element"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#2923",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2923"
}
]
},
"source": {
"defect": [
"RD-2923"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29022",
"datePublished": "2021-02-16T15:08:36.021Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-09-16T16:18:06.251Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29024 (GCVE-0-2020-29024)
Vulnerability from cvelistv5 – Published: 2021-02-16 15:07 – Updated: 2024-09-16 16:38
VLAI?
Title
Missing HtppOnly and Secure flags
Summary
Sensitive Cookie in HTTPS Session Without 'Secure' Attribute vulnerability in (GTA) GoToAppliance of Secomea GateManager could allow an attacker to gain access to sensitive cookies. This issue affects: Secomea GateManager all versions prior to 9.3.
Severity ?
5.3 (Medium)
CWE
- CWE-614 - Sensitive Cookie in HTTPS Session Without 'Secure' Attribute
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
all , < 9.3
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.408Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2418"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.3",
"status": "affected",
"version": "all",
"versionType": "custom"
}
]
}
],
"datePublic": "2021-02-16T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute vulnerability in (GTA) GoToAppliance of Secomea GateManager could allow an attacker to gain access to sensitive cookies. This issue affects: Secomea GateManager all versions prior to 9.3."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-614",
"description": "CWE-614 Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-16T15:07:41.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2418"
}
],
"source": {
"defect": [
"RD-2418"
],
"discovery": "EXTERNAL"
},
"title": "Missing HtppOnly and Secure flags",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"DATE_PUBLIC": "2021-02-16T00:00:00.000Z",
"ID": "CVE-2020-29024",
"STATE": "PUBLIC",
"TITLE": "Missing HtppOnly and Secure flags"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "all",
"version_value": "9.3"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute vulnerability in (GTA) GoToAppliance of Secomea GateManager could allow an attacker to gain access to sensitive cookies. This issue affects: Secomea GateManager all versions prior to 9.3."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-614 Sensitive Cookie in HTTPS Session Without \u0027Secure\u0027 Attribute"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#2418",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2418"
}
]
},
"source": {
"defect": [
"RD-2418"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29024",
"datePublished": "2021-02-16T15:07:41.787Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-09-16T16:38:40.890Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29031 (GCVE-0-2020-29031)
Vulnerability from cvelistv5 – Published: 2021-02-15 15:52 – Updated: 2024-08-04 16:48
VLAI?
Title
Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation
Summary
An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c
Severity ?
7.1 (High)
CWE
- CWE-280 - Improper Handling of Insufficient Permissions or Privileges
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , < 9.2c
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:00.792Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2920"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.2c",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c"
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-280",
"description": "CWE-280 Improper Handling of Insufficient Permissions or Privileges",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-15T15:52:30.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2920"
}
],
"source": {
"defect": [
"RD-2920"
],
"discovery": "EXTERNAL"
},
"title": "Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2020-29031",
"STATE": "PUBLIC",
"TITLE": "Insecure Direct Object Reference in GateManager WebUI can cause privilege escalation"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.2c"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An Insecure Direct Object Reference vulnerability exists in the web UI of the GateManager which allows an authenticated attacker to reset the password of any user in its domain or any sub-domain, via escalation of privileges. This issue affects all GateManager versions prior to 9.2c"
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:L/A:N",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-280 Improper Handling of Insufficient Permissions or Privileges"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#2920",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2920"
}
]
},
"source": {
"defect": [
"RD-2920"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29031",
"datePublished": "2021-02-15T15:52:30.000Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:00.792Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CVE-2020-29026 (GCVE-0-2020-29026)
Vulnerability from cvelistv5 – Published: 2021-02-15 15:48 – Updated: 2024-08-04 16:48
VLAI?
Summary
A directory traversal vulnerability exists in the file upload function of the GateManager that allows an authenticated attacker with administrative permissions to read and write arbitrary files in the Linux file system. This issue affects: GateManager all versions prior to 9.2c.
Severity ?
9 (Critical)
CWE
- CWE-22 - Improper Limitation of a Pathname to a Restricted Directory ('Path Traversal')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Secomea | GateManager |
Affected:
All , < 9.2c
(custom)
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:48:01.207Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2918"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "GateManager",
"vendor": "Secomea",
"versions": [
{
"lessThan": "9.2c",
"status": "affected",
"version": "All",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A directory traversal vulnerability exists in the file upload function of the GateManager that allows an authenticated attacker with administrative permissions to read and write arbitrary files in the Linux file system. This issue affects: GateManager all versions prior to 9.2c."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-22",
"description": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-02-15T15:48:30.000Z",
"orgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"shortName": "Secomea"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2918"
}
],
"source": {
"defect": [
"RD-2918"
],
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "VulnerabilityReporting@secomea.com",
"ID": "CVE-2020-29026",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "GateManager",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "All",
"version_value": "9.2c"
}
]
}
}
]
},
"vendor_name": "Secomea"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A directory traversal vulnerability exists in the file upload function of the GateManager that allows an authenticated attacker with administrative permissions to read and write arbitrary files in the Linux file system. This issue affects: GateManager all versions prior to 9.2c."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 9,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "CHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:L",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-22 Improper Limitation of a Pathname to a Restricted Directory (\u0027Path Traversal\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.secomea.com/support/cybersecurity-advisory/#2918",
"refsource": "MISC",
"url": "https://www.secomea.com/support/cybersecurity-advisory/#2918"
}
]
},
"source": {
"defect": [
"RD-2918"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "f2815942-3388-4c08-ba09-6c15850fda90",
"assignerShortName": "Secomea",
"cveId": "CVE-2020-29026",
"datePublished": "2021-02-15T15:48:30.000Z",
"dateReserved": "2020-11-24T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:48:01.207Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}