Search criteria

4 vulnerabilities found for Metasys by Johnson Controls

CVE-2025-26385 (GCVE-0-2025-26385)

Vulnerability from cvelistv5 – Published: 2026-01-30 11:05 – Updated: 2026-01-30 12:38
VLAI?
Title
Metasys product command injection vulnerability could allow remote SQL execution
Summary
Johnson Controls Metasys component listed below have Improper Neutralization of Special Elements used in a Command (Command Injection) Vulnerability . Successful exploitation of this vulnerability could allow remote SQL execution This issue affects  * Metasys: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation,  * Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation,  * LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1,  * System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior,  * Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior.
CWE
  • CWE-77 - Improper Neutralization of Special Elements used in a Command ('Command Injection')
Assigner
jci
Impacted products
Vendor Product Version
Johnson Controls Metasys Affected: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation (custom)
Affected: Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation (custom)
Affected: LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1 (custom)
Affected: System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior (custom)
Affected: Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-26385",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-30T12:37:58.863009Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-30T12:38:11.405Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "modules": [
            "Application and Data Server (ADS)",
            "Extended Application and Data Server",
            "LCS8500 or NAE8500  (ADX)",
            "Controller Configuration Tool (CCT)",
            "System Configuration Tool (SCT)"
          ],
          "product": "Metasys",
          "vendor": "Johnson Controls",
          "versions": [
            {
              "status": "affected",
              "version": "Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior",
              "versionType": "custom"
            },
            {
              "status": "affected",
              "version": "Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2026-01-27T10:39:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u0026nbsp;Johnson Controls Metasys component listed below have  Improper Neutralization of Special Elements used in a Command (Command Injection) Vulnerability . Successful exploitation of this vulnerability could allow remote SQL execution \u003cp\u003eThis issue affects\u0026nbsp;\u003c/p\u003e\u003cp\u003e\u003c/p\u003e\u003cul\u003e\u003cli\u003eMetasys: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation,\u0026nbsp;\u003c/li\u003e\u003cli\u003eExtended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation,\u0026nbsp;\u003c/li\u003e\u003cli\u003eLCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1,\u0026nbsp;\u003c/li\u003e\u003cli\u003eSystem Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior,\u0026nbsp;\u003c/li\u003e\u003cli\u003eController Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior.\u003c/li\u003e\u003c/ul\u003e\u003cp\u003e\u003c/p\u003e"
            }
          ],
          "value": "Johnson Controls Metasys component listed below have  Improper Neutralization of Special Elements used in a Command (Command Injection) Vulnerability . Successful exploitation of this vulnerability could allow remote SQL execution This issue affects\u00a0\n\n\n\n  *  Metasys: Application and Data Server (ADS) installed with SQL Express deployed as part of the Metasys 14.1 and prior installation,\u00a0\n  *  Extended Application and Data Server (ADX) installed with SQL Express deployed as part of the Metasys 14.1 installation,\u00a0\n  *  LCS8500 or NAE8500 installed with SQL Express deployed as part of the Metasys installation Releases 12.0 through 14.1,\u00a0\n  *  System Configuration Tool (SCT) installed with SQL Express deployed as part of the SCT installation 17.1 and prior,\u00a0\n  *  Controller Configuration Tool (CCT) installed with SQL Express deployed as part of the CCT installation 17.0 and prior."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-248",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-248 Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "PRESENT",
            "attackVector": "NETWORK",
            "baseScore": 9.5,
            "baseSeverity": "CRITICAL",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "HIGH",
            "subConfidentialityImpact": "HIGH",
            "subIntegrityImpact": "HIGH",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-77",
              "description": "CWE-77 Improper Neutralization of Special Elements used in a Command (\u0027Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-30T11:05:16.688Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-26-027-04"
        },
        {
          "url": "https://www.johnsoncontrols.com/trust-center/cybersecurity/security-advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "a.  Follow the Johnson Controls hardening guide steps to ensure your Metasys installation is on a segmented network, not exposed to untrusted networks such as the internet\u003cbr\u003eb.  Download and execute the Metasys patch for GIV-165989 from the License Portal \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://software.jci.com/licenseportal/\"\u003ehttps://software.jci.com/licenseportal/\u003c/a\u003e.  Login credentials are required\u003cbr\u003ec.  Close incoming TCP port 1433\u003cbr\u003ed.  For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-02 at the following location: \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.johnsoncontrols.com/cyber-solutions/security-advisories\"\u003ehttps://www.johnsoncontrols.com/cyber-solutions/security-advisories\u003c/a\u003e\u003cbr\u003e"
            }
          ],
          "value": "a.  Follow the Johnson Controls hardening guide steps to ensure your Metasys installation is on a segmented network, not exposed to untrusted networks such as the internet\nb.  Download and execute the Metasys patch for GIV-165989 from the License Portal  https://software.jci.com/licenseportal/ .  Login credentials are required\nc.  Close incoming TCP port 1433\nd.  For more detailed mitigation instructions, please see Johnson Controls Product Security Advisory JCI-PSA-2026-02 at the following location:  https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Metasys product command injection vulnerability could allow remote SQL execution",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2025-26385",
    "datePublished": "2026-01-30T11:05:16.688Z",
    "dateReserved": "2025-02-07T14:15:53.880Z",
    "dateUpdated": "2026-01-30T12:38:11.405Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2021-36205 (GCVE-0-2021-36205)

Vulnerability from cvelistv5 – Published: 2022-04-15 16:24 – Updated: 2024-09-16 23:41
VLAI?
Title
Metasys session token
Summary
Under certain circumstances the session token is not cleared on logout.
CWE
Assigner
jci
References
Impacted products
Vendor Product Version
Johnson Controls Metasys Affected: All 10 versions , < 10.1.5 (custom)
Affected: All 11 versions , < 11.0.2 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:50.703Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
          },
          {
            "name": "ICS-CERT Advisory",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Metasys",
          "vendor": "Johnson Controls",
          "versions": [
            {
              "lessThan": "10.1.5",
              "status": "affected",
              "version": "All 10 versions",
              "versionType": "custom"
            },
            {
              "lessThan": "11.0.2",
              "status": "affected",
              "version": "All 11 versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2022-04-14T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Under certain circumstances the session token is not cleared on logout."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-459",
              "description": "CWE-459: Incomplete Cleanup",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-15T16:24:48.000Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
        },
        {
          "name": "ICS-CERT Advisory",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update all Metasys ADS/ADX/OAS 10 versions with patch 10.1.5"
        },
        {
          "lang": "en",
          "value": "Update all Metasys ADS/ADX/OAS 11 versions with patch 11.0.2"
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Metasys session token",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productsecurity@jci.com",
          "DATE_PUBLIC": "2022-04-14T20:43:00.000Z",
          "ID": "CVE-2021-36205",
          "STATE": "PUBLIC",
          "TITLE": "Metasys session token"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Metasys",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All 10 versions",
                            "version_value": "10.1.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "All 11 versions",
                            "version_value": "11.0.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Johnson Controls"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Under certain circumstances the session token is not cleared on logout."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.1,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-459: Incomplete Cleanup"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories",
              "refsource": "CONFIRM",
              "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
            },
            {
              "name": "ICS-CERT Advisory",
              "refsource": "CERT",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-104-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update all Metasys ADS/ADX/OAS 10 versions with patch 10.1.5"
          },
          {
            "lang": "en",
            "value": "Update all Metasys ADS/ADX/OAS 11 versions with patch 11.0.2"
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2021-36205",
    "datePublished": "2022-04-15T16:24:48.570Z",
    "dateReserved": "2021-07-06T00:00:00.000Z",
    "dateUpdated": "2024-09-16T23:41:01.659Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-36202 (GCVE-0-2021-36202)

Vulnerability from cvelistv5 – Published: 2022-04-07 19:12 – Updated: 2024-09-17 01:50
VLAI?
Title
Metasys UI
Summary
Server-Side Request Forgery (SSRF) vulnerability in Johnson Controls Metasys could allow an authenticated attacker to inject malicious code into the MUI PDF export feature. This issue affects: Johnson Controls Metasys All 10 versions versions prior to 10.1.5; All 11 versions versions prior to 11.0.2.
CWE
  • CWE-918 - Server-Side Request Forgery (SSRF)
Assigner
jci
References
Impacted products
Vendor Product Version
Johnson Controls Metasys Affected: All 10 versions , < 10.1.5 (custom)
Affected: All 11 versions , < 11.0.2 (custom)
Create a notification for this product.
Credits
Tony West
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:54:50.839Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
          },
          {
            "name": "ICS-CERT Advisory",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Metasys",
          "vendor": "Johnson Controls",
          "versions": [
            {
              "lessThan": "10.1.5",
              "status": "affected",
              "version": "All 10 versions",
              "versionType": "custom"
            },
            {
              "lessThan": "11.0.2",
              "status": "affected",
              "version": "All 11 versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Tony West"
        }
      ],
      "datePublic": "2022-04-07T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Server-Side Request Forgery (SSRF) vulnerability in Johnson Controls Metasys could allow an authenticated attacker to inject malicious code into the MUI PDF export feature. This issue affects: Johnson Controls Metasys All 10 versions versions prior to 10.1.5; All 11 versions versions prior to 11.0.2."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-918",
              "description": "CWE-918: Server-Side Request Forgery (SSRF)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-04-07T19:13:04.000Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
        },
        {
          "name": "ICS-CERT Advisory",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Update all Metasys ADS/ADX/OAS 10 versions with patch 10.1.5."
        },
        {
          "lang": "en",
          "value": "Update all Metasys ADS/ADX/OAS 11 versions with patch 11.0.2."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Metasys UI",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productsecurity@jci.com",
          "DATE_PUBLIC": "2022-04-07T13:07:00.000Z",
          "ID": "CVE-2021-36202",
          "STATE": "PUBLIC",
          "TITLE": "Metasys UI"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Metasys",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "All 10 versions",
                            "version_value": "10.1.5"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "All 11 versions",
                            "version_value": "11.0.2"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Johnson Controls"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Tony West"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Server-Side Request Forgery (SSRF) vulnerability in Johnson Controls Metasys could allow an authenticated attacker to inject malicious code into the MUI PDF export feature. This issue affects: Johnson Controls Metasys All 10 versions versions prior to 10.1.5; All 11 versions versions prior to 11.0.2."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:C/C:H/I:H/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-918: Server-Side Request Forgery (SSRF)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories",
              "refsource": "CONFIRM",
              "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
            },
            {
              "name": "ICS-CERT Advisory",
              "refsource": "CERT",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-095-02"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Update all Metasys ADS/ADX/OAS 10 versions with patch 10.1.5."
          },
          {
            "lang": "en",
            "value": "Update all Metasys ADS/ADX/OAS 11 versions with patch 11.0.2."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2021-36202",
    "datePublished": "2022-04-07T19:12:48.421Z",
    "dateReserved": "2021-07-06T00:00:00.000Z",
    "dateUpdated": "2024-09-17T01:50:52.203Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27657 (GCVE-0-2021-27657)

Vulnerability from cvelistv5 – Published: 2021-06-04 14:07 – Updated: 2024-09-17 00:51
VLAI?
Title
Metasys Improper Privilege Management
Summary
Successful exploitation of this vulnerability could give an authenticated Metasys user an unintended level of access to the server file system, allowing them to access or modify system files by sending specifically crafted web messages to the Metasys system. This issue affects: Johnson Controls Metasys version 11.0 and prior versions.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
jci
References
https://www.johnsoncontrols.com/cyber-solutions/s… x_refsource_CONFIRM
https://us-cert.gov/ics/advisories third-party-advisoryx_refsource_CERT
https://us-cert.cisa.gov/ics/advisories/icsa-21-159-01 third-party-advisoryx_refsource_CERT
Impacted products
Vendor Product Version
Johnson Controls Metasys Affected: 11.0 , ≤ 11.0 (custom)
Create a notification for this product.
Credits
Jakub Palaczynski
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T21:26:10.694Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
          },
          {
            "name": "ICS-CERT Advisory",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT",
              "x_transferred"
            ],
            "url": "https://us-cert.gov/ics/advisories"
          },
          {
            "name": "ICS-CERT Advisory",
            "tags": [
              "third-party-advisory",
              "x_refsource_CERT",
              "x_transferred"
            ],
            "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Metasys",
          "vendor": "Johnson Controls",
          "versions": [
            {
              "lessThanOrEqual": "11.0",
              "status": "affected",
              "version": "11.0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Jakub Palaczynski"
        }
      ],
      "datePublic": "2021-06-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Successful exploitation of this vulnerability could give an authenticated Metasys user an unintended level of access to the server file system, allowing them to access or modify system files by sending specifically crafted web messages to the Metasys system. This issue affects: Johnson Controls Metasys version 11.0 and prior versions."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-23T10:45:14.000Z",
        "orgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
        "shortName": "jci"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
        },
        {
          "name": "ICS-CERT Advisory",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT"
          ],
          "url": "https://us-cert.gov/ics/advisories"
        },
        {
          "name": "ICS-CERT Advisory",
          "tags": [
            "third-party-advisory",
            "x_refsource_CERT"
          ],
          "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "For Metasys versions previous to 9.0: Upgrade to a supported release. This is true for all the items except for Metasys Release 8.1 UL/cUL 864 UUKL 10th Edition Smoke Control."
        },
        {
          "lang": "en",
          "value": "For Metasys versions 9.0 (engine only), 10.0, 10.1, 11.0: Install patch."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "Metasys Improper Privilege Management",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "productsecurity@jci.com",
          "DATE_PUBLIC": "2021-06-04T05:01:00.000Z",
          "ID": "CVE-2021-27657",
          "STATE": "PUBLIC",
          "TITLE": "Metasys Improper Privilege Management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Metasys",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c=",
                            "version_name": "11.0",
                            "version_value": "11.0"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Johnson Controls"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Jakub Palaczynski"
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Successful exploitation of this vulnerability could give an authenticated Metasys user an unintended level of access to the server file system, allowing them to access or modify system files by sending specifically crafted web messages to the Metasys system. This issue affects: Johnson Controls Metasys version 11.0 and prior versions."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories",
              "refsource": "CONFIRM",
              "url": "https://www.johnsoncontrols.com/cyber-solutions/security-advisories"
            },
            {
              "name": "ICS-CERT Advisory",
              "refsource": "CERT",
              "url": "https://us-cert.gov/ics/advisories"
            },
            {
              "name": "ICS-CERT Advisory",
              "refsource": "CERT",
              "url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-159-01"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "For Metasys versions previous to 9.0: Upgrade to a supported release. This is true for all the items except for Metasys Release 8.1 UL/cUL 864 UUKL 10th Edition Smoke Control."
          },
          {
            "lang": "en",
            "value": "For Metasys versions 9.0 (engine only), 10.0, 10.1, 11.0: Install patch."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7281d04a-a537-43df-bfb4-fa4110af9d01",
    "assignerShortName": "jci",
    "cveId": "CVE-2021-27657",
    "datePublished": "2021-06-04T14:07:39.073Z",
    "dateReserved": "2021-02-24T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:51:44.651Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}