CVE-2025-41728 (GCVE-0-2025-41728)

Vulnerability from cvelistv5 – Published: 2026-01-27 11:37 – Updated: 2026-01-27 13:49
VLAI?
Title
Beckhoff: Information leak via Beckhoff Device Manager
Summary
A low privileged remote attacker may be able to disclose confidential information from the memory of a privileged process by sending specially crafted calls to the Device Manager web service that cause an out-of-bounds read operation under certain circumstances due to ASLR and thereby potentially copy confidential information into a response.
CWE
Assigner
Credits
Diego Giubertoni from Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41728",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-27T13:49:39.412692Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-27T13:49:51.297Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Beckhoff.Device.Manager.XAR",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "2.5.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MDP software package for TwinCAT/BSD",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "1.7.0.0",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MDP for Beckhoff RT Linux(R)",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "0.0.5",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Diego Giubertoni from Nozomi Networks"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A low privileged remote attacker may be able to disclose confidential information from the memory of a privileged process by sending specially crafted calls to the Device Manager web service that cause an out-of-bounds read operation under certain circumstances due to ASLR and thereby potentially copy confidential information into a response.\u003cbr\u003e"
            }
          ],
          "value": "A low privileged remote attacker may be able to disclose confidential information from the memory of a privileged process by sending specially crafted calls to the Device Manager web service that cause an out-of-bounds read operation under certain circumstances due to ASLR and thereby potentially copy confidential information into a response."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-125",
              "description": "CWE-125 Out-of-bounds Read",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-27T11:37:55.689Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-092"
        }
      ],
      "source": {
        "advisory": "VDE-2025-092",
        "defect": [
          "CERT@VDE#641867"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Beckhoff: Information leak via Beckhoff Device Manager",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41728",
    "datePublished": "2026-01-27T11:37:55.689Z",
    "dateReserved": "2025-04-16T11:17:48.318Z",
    "dateUpdated": "2026-01-27T13:49:51.297Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41727 (GCVE-0-2025-41727)

Vulnerability from cvelistv5 – Published: 2026-01-27 11:36 – Updated: 2026-01-27 13:53
VLAI?
Title
Beckhoff: Performing privileged operations and gaining administrator access
Summary
A local low privileged attacker can bypass the authentication of the Device Manager user interface, allowing them to perform privileged operations and gain administrator access.
CWE
  • CWE-420 - Unprotected Alternate Channel
Assigner
Credits
Diego Giubertoni from Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41727",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-27T13:52:11.980827Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-27T13:53:55.876Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Beckhoff.Device.Manager.XAR",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "2.5.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MDP software package for TwinCAT/BSD",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "1.7.0.0",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MDP for Beckhoff RT Linux(R)",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "0.0.5",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Diego Giubertoni from Nozomi Networks"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A local low privileged attacker can bypass the authentication of the Device Manager user interface, allowing them to perform privileged operations and gain administrator access.\u003cbr\u003e"
            }
          ],
          "value": "A local low privileged attacker can bypass the authentication of the Device Manager user interface, allowing them to perform privileged operations and gain administrator access."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-420",
              "description": "CWE-420 Unprotected Alternate Channel",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-27T11:36:54.619Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-092"
        }
      ],
      "source": {
        "advisory": "VDE-2025-092",
        "defect": [
          "CERT@VDE#641867"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Beckhoff:  Performing privileged operations and gaining administrator access",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41727",
    "datePublished": "2026-01-27T11:36:54.619Z",
    "dateReserved": "2025-04-16T11:17:48.318Z",
    "dateUpdated": "2026-01-27T13:53:55.876Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41726 (GCVE-0-2025-41726)

Vulnerability from cvelistv5 – Published: 2026-01-27 11:35 – Updated: 2026-01-27 14:08
VLAI?
Title
Beckhoff: Arbitrary code execution within privileged processes
Summary
A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes.
CWE
  • CWE-190 - Integer Overflow or Wraparound
Assigner
Credits
Diego Giubertoni from Nozomi Networks
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41726",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-27T14:02:23.024430Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-27T14:08:37.385Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Beckhoff.Device.Manager.XAR",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "2.5.3",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MDP software package for TwinCAT/BSD",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "1.7.0.0",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MDP for Beckhoff RT Linux(R)",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "0.0.5",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Diego Giubertoni from Nozomi Networks"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes.\u003cbr\u003e"
            }
          ],
          "value": "A low privileged remote attacker can execute arbitrary code by sending specially crafted calls to the web service of the Device Manager or locally via an API and can cause integer overflows which then may lead to arbitrary code execution within privileged processes."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-190",
              "description": "CWE-190 Integer Overflow or Wraparound",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-01-27T11:35:37.391Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-092"
        }
      ],
      "source": {
        "advisory": "VDE-2025-092",
        "defect": [
          "CERT@VDE#641867"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Beckhoff: Arbitrary code execution within privileged processes",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41726",
    "datePublished": "2026-01-27T11:35:37.391Z",
    "dateReserved": "2025-04-16T11:17:48.318Z",
    "dateUpdated": "2026-01-27T14:08:37.385Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2025-41768 (GCVE-0-2025-41768)

Vulnerability from cvelistv5 – Published: 2026-01-20 08:02 – Updated: 2026-02-12 09:00
VLAI?
Title
Beckhoff: XSS Vulnerability in TwinCAT 3 HMI Server
Summary
An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation ('Cross-site Scripting').
CWE
  • CWE-79 - Improper Neutralization of Input During Web Page Generation ('Cross-site Scripting')
Assigner
Impacted products
Vendor Product Version
Beckhoff Automation TwinCAT.HMI.Server Affected: 0.0.0 , < 14.4.267 (semver)
Create a notification for this product.
Credits
Roby Firnando Yusuf from Jeonbuk National University
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-41768",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-01-20T19:30:51.378202Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-01-20T19:32:34.439Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "TwinCAT.HMI.Server",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "14.4.267",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TF2000-HMI-Server",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "14.4.267",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "tf2000-hmi-server",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "14.4.267",
              "status": "affected",
              "version": "0.0.0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Roby Firnando Yusuf from Jeonbuk National University"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027)."
            }
          ],
          "value": "An high privileged remote attacker can inject arbitrary content into the custom CSS field on the affected devices due to improper neutralization of input during web page generation (\u0027Cross-site Scripting\u0027)."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:L/I:L/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79 Improper Neutralization of Input During Web Page Generation (\u0027Cross-site Scripting\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-02-12T09:00:27.685Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "url": "https://certvde.com/de/advisories/VDE-2025-106"
        }
      ],
      "source": {
        "advisory": "VDE-2025-106",
        "defect": [
          "CERT@VDE#641900"
        ],
        "discovery": "UNKNOWN"
      },
      "title": "Beckhoff: XSS Vulnerability in TwinCAT 3 HMI Server",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2025-41768",
    "datePublished": "2026-01-20T08:02:53.356Z",
    "dateReserved": "2025-04-16T11:18:45.761Z",
    "dateUpdated": "2026-02-12T09:00:27.685Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2021-34594 (GCVE-0-2021-34594)

Vulnerability from cvelistv5 – Published: 2021-11-04 09:50 – Updated: 2024-09-16 22:03
VLAI?
Title
Beckhoff: Relative path traversal vulnerability through TwinCAT OPC UA Server
Summary
TwinCAT OPC UA Server in TF6100 and TS6100 in product versions before 4.3.48.0 or with TcOpcUaServer versions below 3.2.0.194 are prone to a relative path traversal that allow administrators to create or delete any files on the system.
CWE
  • CWE-23 - Relative Path Traversal
Assigner
References
Impacted products
Vendor Product Version
Beckhoff Automation TwinCAT OPC UA Server Affected: TF6100 , < 4.3.48.0 (custom)
Affected: TS6100 , < 4.3.48.0 (custom)
Affected: TcOpcUaServer version , < 3.2.0.19423 (custom)
Create a notification for this product.
Credits
Beckhoff Automation thanks Johannes Olegård, Emre Süren, and Robert Lagerström for reporting the issue and for support and efforts with the coordinated disclosure.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T00:19:46.994Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://cert.vde.com/en/advisories/VDE-2021-051/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "TwinCAT OPC UA Server",
          "vendor": "Beckhoff Automation",
          "versions": [
            {
              "lessThan": "4.3.48.0",
              "status": "affected",
              "version": "TF6100",
              "versionType": "custom"
            },
            {
              "lessThan": "4.3.48.0",
              "status": "affected",
              "version": "TS6100",
              "versionType": "custom"
            },
            {
              "lessThan": "3.2.0.19423",
              "status": "affected",
              "version": "TcOpcUaServer version",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Beckhoff Automation thanks Johannes Oleg\u00e5rd, Emre S\u00fcren, and Robert Lagerstr\u00f6m for reporting the issue and for support and efforts with the coordinated disclosure."
        }
      ],
      "datePublic": "2021-11-04T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "TwinCAT OPC UA Server in TF6100 and TS6100 in product versions before 4.3.48.0 or with TcOpcUaServer versions below 3.2.0.194 are prone to a relative path traversal that allow administrators to create or delete any files on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23 Relative Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-11-04T09:50:09.000Z",
        "orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
        "shortName": "CERTVDE"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://cert.vde.com/en/advisories/VDE-2021-051/"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "Please update to a recent version of the affected product (TF6100 or TS6100 version \u003e= 4.3.48.0)"
        }
      ],
      "source": {
        "advisory": "VDE-2021-051",
        "discovery": "EXTERNAL"
      },
      "title": "Beckhoff: Relative path traversal vulnerability through TwinCAT OPC UA Server",
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "info@cert.vde.com",
          "DATE_PUBLIC": "2021-11-04T06:00:00.000Z",
          "ID": "CVE-2021-34594",
          "STATE": "PUBLIC",
          "TITLE": "Beckhoff: Relative path traversal vulnerability through TwinCAT OPC UA Server"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "TwinCAT OPC UA Server",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_name": "TF6100",
                            "version_value": "4.3.48.0"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "TS6100",
                            "version_value": "4.3.48.0"
                          },
                          {
                            "version_affected": "\u003c",
                            "version_name": "TcOpcUaServer version",
                            "version_value": "3.2.0.19423"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "Beckhoff Automation"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Beckhoff Automation thanks Johannes Oleg\u00e5rd, Emre S\u00fcren, and Robert Lagerstr\u00f6m for reporting the issue and for support and efforts with the coordinated disclosure."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "TwinCAT OPC UA Server in TF6100 and TS6100 in product versions before 4.3.48.0 or with TcOpcUaServer versions below 3.2.0.194 are prone to a relative path traversal that allow administrators to create or delete any files on the system."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-23 Relative Path Traversal"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://cert.vde.com/en/advisories/VDE-2021-051/",
              "refsource": "CONFIRM",
              "url": "https://cert.vde.com/en/advisories/VDE-2021-051/"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "Please update to a recent version of the affected product (TF6100 or TS6100 version \u003e= 4.3.48.0)"
          }
        ],
        "source": {
          "advisory": "VDE-2021-051",
          "discovery": "EXTERNAL"
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
    "assignerShortName": "CERTVDE",
    "cveId": "CVE-2021-34594",
    "datePublished": "2021-11-04T09:50:09.275Z",
    "dateReserved": "2021-06-10T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:03:44.063Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}