Search criteria

33 vulnerabilities by GE

CVE-2024-6098 (GCVE-0-2024-6098)

Vulnerability from cvelistv5 – Published: 2024-08-16 14:57 – Updated: 2024-08-19 17:32
VLAI?
Title
PTC Kepware ThingWorx Kepware Server Allocation of Resources Without Limits or Throttling
Summary
When performing an online tag generation to devices which communicate using the ControlLogix protocol, a machine-in-the-middle, or a device that is not configured correctly, could deliver a response leading to unrestricted or unregulated resource allocation. This could cause a denial-of-service condition and crash the Kepware application. By default, these functions are turned off, yet they remain accessible for users who recognize and require their advantages.
CWE
  • CWE-770 - Allocation of Resources Without Limits or Throttling
Assigner
Credits
Sharon Brizinov and Vera Mens of Claroty Research - Team82 reported this vulnerability to PTC.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-6098",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-08-19T17:32:29.303502Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-08-19T17:32:48.721Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Kepware ThingWorx Kepware Server",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "V6"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Kepware KEPServerEX",
          "vendor": "PTC",
          "versions": [
            {
              "status": "affected",
              "version": "V6"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "TOP Server",
          "vendor": "Software Toolbox",
          "versions": [
            {
              "status": "affected",
              "version": "V6"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "IGS",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "V7.6x"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Sharon Brizinov and Vera Mens of Claroty Research - Team82 reported this vulnerability to PTC."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "When performing an online tag generation to devices which communicate \nusing the ControlLogix protocol, a machine-in-the-middle, or a device \nthat is not configured correctly, could deliver a response leading to \nunrestricted or unregulated resource allocation. This could cause a \ndenial-of-service condition and crash the Kepware application. By \ndefault, these functions are turned off, yet they remain accessible for \nusers who recognize and require their advantages."
            }
          ],
          "value": "When performing an online tag generation to devices which communicate \nusing the ControlLogix protocol, a machine-in-the-middle, or a device \nthat is not configured correctly, could deliver a response leading to \nunrestricted or unregulated resource allocation. This could cause a \ndenial-of-service condition and crash the Kepware application. By \ndefault, these functions are turned off, yet they remain accessible for \nusers who recognize and require their advantages."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:H/PR:N/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "HIGH",
            "attackRequirements": "PRESENT",
            "attackVector": "ADJACENT",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:A/AC:H/AT:P/PR:N/UI:P/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "NONE",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-770",
              "description": "CWE-770 Allocation of Resources Without Limits or Throttling",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-08-16T14:57:51.023Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-228-11"
        },
        {
          "url": "https://www.ptc.com/en/support/article/CS423892"
        }
      ],
      "source": {
        "advisory": "ICSA-24-228-11",
        "discovery": "EXTERNAL"
      },
      "title": "PTC Kepware ThingWorx Kepware Server Allocation of Resources Without Limits or Throttling",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "PTC recommends users take a defense-in-depth stance with regards to \ntheir manufacturing networks ensuring proper access control is \nmaintained. Additionally, proper adherence to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/support/-/media/support/refdocs/ThingWorx_Kepware_Server/6,-d-,16/secure_deployment_guide_tks.pdf?sc_lang=en\u0026amp;source=search\"\u003eKepware Secure Deployment Guide\u003c/a\u003e\u003cp\u003e will minimize this threat through accurate configuration and use of the product.\u003c/p\u003e\n\u003cp\u003ePlease refer to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.ptc.com/en/support/article/CS423892\"\u003ethis article (login required)\u003c/a\u003e\u003c/p\u003e\u003cp\u003e for specific information on how this risk may be mitigated in your environment.\u003c/p\u003e\n\u003cp\u003eIf additional questions remain, contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log?\"\u003ePTC Technical Support.\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "PTC recommends users take a defense-in-depth stance with regards to \ntheir manufacturing networks ensuring proper access control is \nmaintained. Additionally, proper adherence to the  Kepware Secure Deployment Guide https://www.ptc.com/support/-/media/support/refdocs/ThingWorx_Kepware_Server/6,-d-,16/secure_deployment_guide_tks.pdf  will minimize this threat through accurate configuration and use of the product.\n\n\nPlease refer to  this article (login required) https://www.ptc.com/en/support/article/CS423892 \n\n for specific information on how this risk may be mitigated in your environment.\n\n\nIf additional questions remain, contact  PTC Technical Support. https://support.ptc.com/apps/case_logger_viewer/cs/auth/ssl/log"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-6098",
    "datePublished": "2024-08-16T14:57:51.023Z",
    "dateReserved": "2024-06-17T21:40:20.832Z",
    "dateUpdated": "2024-08-19T17:32:48.721Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3092 (GCVE-0-2022-3092)

Vulnerability from cvelistv5 – Published: 2022-12-07 23:01 – Updated: 2025-04-16 17:40
VLAI?
Title
GE CIMPLICITY Out-of-bounds Write
Summary
GE CIMPICITY versions 2022 and prior is vulnerable to an out-of-bounds write, which could allow an attacker to execute arbitrary code.
CWE
Assigner
Impacted products
Vendor Product Version
GE CIMPLICITY Affected: 0 , ≤ v2022 (custom)
Create a notification for this product.
Credits
Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:00:09.769Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3092",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:25:35.683235Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:40:47.032Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CIMPLICITY",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "v2022",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "coordinator",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2022-11-22T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eGE CIMPICITY versions 2022 and prior is \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003evulnerable to an out-of-bounds write, which could allow an attacker to execute arbitrary code. \u003c/span\u003e\n\n \u003c/span\u003e\n\n \u003c/span\u003e\n\n \u003c/span\u003e\n\n"
            }
          ],
          "value": "GE CIMPICITY versions 2022 and prior is \n\n\n\n\n\nvulnerable to an out-of-bounds write, which could allow an attacker to execute arbitrary code. \n\n \n\n \n\n \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "CWE-787 Out-of-bounds Write",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-07T23:01:34.391Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eGE recommends users refer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2\"\u003eCIMPLICITY Secure Deployment Guide\u003c/a\u003e\u0026nbsp;(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \u003c/p\u003e\u003cp\u003eFor more information about this issue, see the GE Digital Product \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06\"\u003eSecurity Advisory\u003c/a\u003e\u0026nbsp;(login required). \u003c/p\u003e\u003cp\u003eFor further questions, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/CC_Contact\"\u003eGE\u003c/a\u003e. \u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nGE recommends users refer to the  CIMPLICITY Secure Deployment Guide https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2 \u00a0(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \n\nFor more information about this issue, see the GE Digital Product  Security Advisory https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06 \u00a0(login required). \n\nFor further questions, users should contact  GE https://digitalsupport.ge.com/communities/CC_Contact . \n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "GE CIMPLICITY Out-of-bounds Write",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-3092",
    "datePublished": "2022-12-07T23:01:34.391Z",
    "dateReserved": "2022-09-01T19:32:53.105Z",
    "dateUpdated": "2025-04-16T17:40:47.032Z",
    "requesterUserId": "548e5310-2409-4eaf-9220-2910d23bb95a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-3084 (GCVE-0-2022-3084)

Vulnerability from cvelistv5 – Published: 2022-12-07 23:00 – Updated: 2025-04-16 17:41
VLAI?
Title
GE CIMPLICITY Access of Uninitialized Pointer
Summary
GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiRootOptionTable, which could allow an attacker to execute arbitrary code.
CWE
  • CWE-824 - Access of Uninitialized Pointer
Assigner
Impacted products
Vendor Product Version
GE CIMPLICITY Affected: 0 , ≤ v2022 (custom)
Create a notification for this product.
Credits
Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T01:00:09.782Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-3084",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:25:38.328932Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:41:02.767Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CIMPLICITY",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "v2022",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "coordinator",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2022-11-22T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eGE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiRootOptionTable, which could allow an attacker to execute arbitrary code. \u003c/span\u003e\n\n"
            }
          ],
          "value": "GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiRootOptionTable, which could allow an attacker to execute arbitrary code. \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-07T23:00:22.514Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eGE recommends users refer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2\"\u003eCIMPLICITY Secure Deployment Guide\u003c/a\u003e\u0026nbsp;(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \u003c/p\u003e\u003cp\u003eFor more information about this issue, see the GE Digital Product \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06\"\u003eSecurity Advisory\u003c/a\u003e\u0026nbsp;(login required). \u003c/p\u003e\u003cp\u003eFor further questions, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/CC_Contact\"\u003eGE\u003c/a\u003e. \u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nGE recommends users refer to the  CIMPLICITY Secure Deployment Guide https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2 \u00a0(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \n\nFor more information about this issue, see the GE Digital Product  Security Advisory https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06 \u00a0(login required). \n\nFor further questions, users should contact  GE https://digitalsupport.ge.com/communities/CC_Contact . \n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "GE CIMPLICITY Access of Uninitialized Pointer",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-3084",
    "datePublished": "2022-12-07T23:00:22.514Z",
    "dateReserved": "2022-09-01T18:49:08.745Z",
    "dateUpdated": "2025-04-16T17:41:02.767Z",
    "requesterUserId": "548e5310-2409-4eaf-9220-2910d23bb95a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2952 (GCVE-0-2022-2952)

Vulnerability from cvelistv5 – Published: 2022-12-07 22:59 – Updated: 2025-04-16 17:41
VLAI?
Title
GE CIMPLICITY Access of Uninitialized Pointer
Summary
GE CIMPICITY versions 2022 and prior is vulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code.
CWE
  • CWE-824 - Access of Uninitialized Pointer
Assigner
Impacted products
Vendor Product Version
GE CIMPLICITY Affected: 0 , ≤ v2022 (custom)
Create a notification for this product.
Credits
Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:52:59.842Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2952",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:25:40.998399Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:41:18.679Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CIMPLICITY",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "v2022",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "coordinator",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2022-11-22T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eGE CIMPICITY versions 2022 and prior is \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003evulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code.\u003c/span\u003e\n\n \u003c/span\u003e\n\n"
            }
          ],
          "value": "GE CIMPICITY versions 2022 and prior is \n\nvulnerable when data from a faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code.\n\n \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-824",
              "description": "CWE-824 Access of Uninitialized Pointer",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-07T22:59:10.715Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eGE recommends users refer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2\"\u003eCIMPLICITY Secure Deployment Guide\u003c/a\u003e\u0026nbsp;(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \u003c/p\u003e\u003cp\u003eFor more information about this issue, see the GE Digital Product \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06\"\u003eSecurity Advisory\u003c/a\u003e\u0026nbsp;(login required). \u003c/p\u003e\u003cp\u003eFor further questions, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/CC_Contact\"\u003eGE\u003c/a\u003e. \u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nGE recommends users refer to the  CIMPLICITY Secure Deployment Guide https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2 \u00a0(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \n\nFor more information about this issue, see the GE Digital Product  Security Advisory https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06 \u00a0(login required). \n\nFor further questions, users should contact  GE https://digitalsupport.ge.com/communities/CC_Contact . \n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "GE CIMPLICITY Access of Uninitialized Pointer",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2952",
    "datePublished": "2022-12-07T22:59:10.715Z",
    "dateReserved": "2022-08-22T19:31:51.879Z",
    "dateUpdated": "2025-04-16T17:41:18.679Z",
    "requesterUserId": "548e5310-2409-4eaf-9220-2910d23bb95a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2948 (GCVE-0-2022-2948)

Vulnerability from cvelistv5 – Published: 2022-12-07 22:58 – Updated: 2025-04-16 17:41
VLAI?
Title
GE CIMPLICITY Heap-based Buffer Overflow
Summary
GE CIMPICITY versions 2022 and prior is vulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code.
CWE
  • CWE-122 - Heap-based Buffer Overflow
Assigner
Impacted products
Vendor Product Version
GE CIMPLICITY Affected: 0 , ≤ v2022 (custom)
Create a notification for this product.
Credits
Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:53:00.630Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2948",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:25:43.607131Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:41:36.455Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CIMPLICITY",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "v2022",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "coordinator",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2022-11-22T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eGE CIMPICITY versions 2022 and prior is \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003evulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code. \u003c/span\u003e\n\n \u003c/span\u003e\n\n"
            }
          ],
          "value": "GE CIMPICITY versions 2022 and prior is \n\nvulnerable to a heap-based buffer overflow, which could allow an attacker to execute arbitrary code. \n\n \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "CWE-122 Heap-based Buffer Overflow",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-07T22:58:15.094Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eGE recommends users refer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2\"\u003eCIMPLICITY Secure Deployment Guide\u003c/a\u003e\u0026nbsp;(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \u003c/p\u003e\u003cp\u003eFor more information about this issue, see the GE Digital Product \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06\"\u003eSecurity Advisory\u003c/a\u003e\u0026nbsp;(login required). \u003c/p\u003e\u003cp\u003eFor further questions, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/CC_Contact\"\u003eGE\u003c/a\u003e. \u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nGE recommends users refer to the  CIMPLICITY Secure Deployment Guide https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2 \u00a0(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \n\nFor more information about this issue, see the GE Digital Product  Security Advisory https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06 \u00a0(login required). \n\nFor further questions, users should contact  GE https://digitalsupport.ge.com/communities/CC_Contact . \n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "GE CIMPLICITY Heap-based Buffer Overflow",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2948",
    "datePublished": "2022-12-07T22:58:15.094Z",
    "dateReserved": "2022-08-22T19:29:24.599Z",
    "dateUpdated": "2025-04-16T17:41:36.455Z",
    "requesterUserId": "548e5310-2409-4eaf-9220-2910d23bb95a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2022-2002 (GCVE-0-2022-2002)

Vulnerability from cvelistv5 – Published: 2022-12-07 22:56 – Updated: 2025-04-16 17:41
VLAI?
Title
GE CIMPLICITY Untrusted Pointer Dereference
Summary
GE CIMPICITY versions 2022 and prior is vulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code.
CWE
  • CWE-822 - Untrusted Pointer Dereference
Assigner
Impacted products
Vendor Product Version
GE CIMPLICITY Affected: 0 , ≤ v2022 (custom)
Create a notification for this product.
Credits
Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T00:24:44.102Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2022-2002",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:25:46.272621Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:41:56.274Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "CIMPLICITY",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "v2022",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "coordinator",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Kimiya working with Trend micro Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "datePublic": "2022-11-22T17:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eGE CIMPICITY versions 2022 and prior is \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003evulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code. \u003c/span\u003e\n\n \u003c/span\u003e\n\n \u003c/span\u003e\n\n"
            }
          ],
          "value": "GE CIMPICITY versions 2022 and prior is \n\n\n\nvulnerable when data from faulting address controls code flow starting at gmmiObj!CGmmiOptionContainer, which could allow an attacker to execute arbitrary code. \n\n \n\n \n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "CWE-822 Untrusted Pointer Dereference",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-12-07T22:56:50.504Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-22-326-04"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cp\u003eGE recommends users refer to the \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2\"\u003eCIMPLICITY Secure Deployment Guide\u003c/a\u003e\u0026nbsp;(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \u003c/p\u003e\u003cp\u003eFor more information about this issue, see the GE Digital Product \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06\"\u003eSecurity Advisory\u003c/a\u003e\u0026nbsp;(login required). \u003c/p\u003e\u003cp\u003eFor further questions, users should contact \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://digitalsupport.ge.com/communities/CC_Contact\"\u003eGE\u003c/a\u003e. \u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nGE recommends users refer to the  CIMPLICITY Secure Deployment Guide https://digitalsupport.ge.com/communities/en_US/Documentation/CIMPLICITY-Secure-Deployment-Guide2 \u00a0(login required) for mitigations to the reported vulnerabilities. Specific sections to reference include Section 3.5 Projects and Section 4.2 CimView. \n\nFor more information about this issue, see the GE Digital Product  Security Advisory https://digitalsupport.ge.com/communities/en_US/Article/GE-Digital-Security-Advisory-GED-22-06 \u00a0(login required). \n\nFor further questions, users should contact  GE https://digitalsupport.ge.com/communities/CC_Contact . \n\n\n\n\n"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "GE CIMPLICITY Untrusted Pointer Dereference",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2022-2002",
    "datePublished": "2022-12-07T22:56:50.504Z",
    "dateReserved": "2022-06-06T20:28:22.383Z",
    "dateUpdated": "2025-04-16T17:41:56.274Z",
    "requesterUserId": "548e5310-2409-4eaf-9220-2910d23bb95a",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-36549 (GCVE-0-2020-36549)

Vulnerability from cvelistv5 – Published: 2022-06-17 13:10 – Updated: 2025-04-16 17:52
VLAI?
Title
GE Voluson S8 Windows Operating System Patches privileges management
Summary
A vulnerability classified as critical was found in GE Voluson S8. Affected is the underlying Windows XP operating system. Missing patches might introduce an excessive attack surface. Access to the local network is required for this attack to succeed.
CWE
  • CWE-269 - Improper Privilege Management
Assigner
References
Impacted products
Vendor Product Version
GE Voluson S8 Affected: n/a
Create a notification for this product.
Credits
Marc Ruef/Rocco Gagliardi
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:30:08.357Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.scip.ch/?news.20200701"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.129835"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-36549",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:28:38.466654Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:52:27.727Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Voluson S8",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Marc Ruef/Rocco Gagliardi"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as critical was found in GE Voluson S8. Affected is the underlying Windows XP operating system. Missing patches might introduce an excessive attack surface. Access to the local network is required for this attack to succeed."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-269",
              "description": "CWE-269 Improper Privilege Management",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-30T23:14:07.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.scip.ch/?news.20200701"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.129835"
        }
      ],
      "title": "GE Voluson S8 Windows Operating System Patches privileges management",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-36549",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "GE Voluson S8 Windows Operating System Patches privileges management"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Voluson S8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": "Marc Ruef/Rocco Gagliardi",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability classified as critical was found in GE Voluson S8. Affected is the underlying Windows XP operating system. Missing patches might introduce an excessive attack surface. Access to the local network is required for this attack to succeed."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "8.8",
            "vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-269 Improper Privilege Management"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.scip.ch/?news.20200701",
              "refsource": "MISC",
              "url": "https://www.scip.ch/?news.20200701"
            },
            {
              "name": "https://vuldb.com/?id.129835",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.129835"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-36549",
    "datePublished": "2022-06-17T13:10:20.000Z",
    "dateReserved": "2022-06-16T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:52:27.727Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-36548 (GCVE-0-2020-36548)

Vulnerability from cvelistv5 – Published: 2022-06-17 13:10 – Updated: 2025-04-16 16:17
VLAI?
Title
GE Voluson S8 Service Browser users.cgi improper authentication
Summary
A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host.
CWE
  • CWE-287 - Improper Authentication
Assigner
References
Impacted products
Vendor Product Version
GE Voluson S8 Affected: n/a
Create a notification for this product.
Credits
Marc Ruef/Rocco Gagliardi
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:30:08.309Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.scip.ch/?news.20200701"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.129834"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-36548",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:51:31.195947Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:17:18.936Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Voluson S8",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Marc Ruef/Rocco Gagliardi"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-30T17:08:25.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.scip.ch/?news.20200701"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.129834"
        }
      ],
      "title": "GE Voluson S8 Service Browser users.cgi improper authentication",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-36548",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "GE Voluson S8 Service Browser users.cgi improper authentication"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Voluson S8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": "Marc Ruef/Rocco Gagliardi",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability classified as problematic has been found in GE Voluson S8. Affected is the file /uscgi-bin/users.cgi of the Service Browser. The manipulation leads to improper authentication and elevated access possibilities. It is possible to launch the attack on the local host."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "5.9",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-287 Improper Authentication"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.scip.ch/?news.20200701",
              "refsource": "MISC",
              "url": "https://www.scip.ch/?news.20200701"
            },
            {
              "name": "https://vuldb.com/?id.129834",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.129834"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-36548",
    "datePublished": "2022-06-17T13:10:18.000Z",
    "dateReserved": "2022-06-16T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:17:18.936Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-36547 (GCVE-0-2020-36547)

Vulnerability from cvelistv5 – Published: 2022-06-17 13:10 – Updated: 2025-04-16 16:17
VLAI?
Title
GE Voluson S8 Service Browser hard-coded credentials
Summary
A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings.
CWE
Assigner
References
Impacted products
Vendor Product Version
GE Voluson S8 Affected: n/a
Create a notification for this product.
Credits
Marc Ruef/Rocco Gagliardi
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T17:30:08.526Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://vuldb.com/?id.129833"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.scip.ch/?news.20200701"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-36547",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:51:35.089763Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:17:26.529Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Voluson S8",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Marc Ruef/Rocco Gagliardi"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "LOW",
            "baseScore": 5.9,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-06-30T17:08:16.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://vuldb.com/?id.129833"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.scip.ch/?news.20200701"
        }
      ],
      "title": "GE Voluson S8 Service Browser hard-coded credentials",
      "x_generator": "vuldb.com",
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-36547",
          "REQUESTER": "cna@vuldb.com",
          "STATE": "PUBLIC",
          "TITLE": "GE Voluson S8 Service Browser hard-coded credentials"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Voluson S8",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": "Marc Ruef/Rocco Gagliardi",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A vulnerability was found in GE Voluson S8. It has been rated as critical. This issue affects the Service Browser which itroduces hard-coded credentials. Attacking locally is a requirement. It is recommended to change the configuration settings."
            }
          ]
        },
        "generator": "vuldb.com",
        "impact": {
          "cvss": {
            "baseScore": "5.9",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://vuldb.com/?id.129833",
              "refsource": "MISC",
              "url": "https://vuldb.com/?id.129833"
            },
            {
              "name": "https://www.scip.ch/?news.20200701",
              "refsource": "MISC",
              "url": "https://www.scip.ch/?news.20200701"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-36547",
    "datePublished": "2022-06-17T13:10:17.000Z",
    "dateReserved": "2022-06-16T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:17:26.529Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27422 (GCVE-0-2021-27422)

Vulnerability from cvelistv5 – Published: 2022-03-23 19:46 – Updated: 2025-04-16 16:40
VLAI?
Title
GE UR family exposure of sensitive information to an unauthorized actor
Summary
GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication.
CWE
Assigner
Impacted products
Vendor Product Version
GE UR family Affected: unspecified , < 8.1x (custom)
Create a notification for this product.
Credits
SCADA-X, DOE’s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:17.116Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-27422",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:59:06.933477Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:40:19.585Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UR family",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "8.1x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-23T19:46:28.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE UR family exposure of sensitive information to an unauthorized actor",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27422",
          "STATE": "PUBLIC",
          "TITLE": "GE UR family exposure of sensitive information to an unauthorized actor"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UR family",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.1x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE UR firmware versions prior to version 8.1x web server interface is supported on UR over HTTP protocol. It allows sensitive information exposure without authentication."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
            },
            {
              "name": "https://www.gegridsolutions.com/Passport/Login.aspx",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27422",
    "datePublished": "2022-03-23T19:46:28.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:40:19.585Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27426 (GCVE-0-2021-27426)

Vulnerability from cvelistv5 – Published: 2022-03-23 19:46 – Updated: 2025-04-16 16:40
VLAI?
Title
GE UR family insecure default variable initialization
Summary
GE UR IED firmware versions prior to version 8.1x with “Basic” security variant does not allow the disabling of the “Factory Mode,” which is used for servicing the IED by a “Factory” user.
CWE
  • CWE-453 - Insecure Default Variable Initialization
Assigner
Impacted products
Vendor Product Version
GE UR family Affected: unspecified , < 8.1x (custom)
Create a notification for this product.
Credits
SCADA-X, DOE’s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:17.118Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-27426",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:57:43.287920Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:40:28.743Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UR family",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "8.1x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "GE UR IED firmware versions prior to version 8.1x with \u201cBasic\u201d security variant does not allow the disabling of the \u201cFactory Mode,\u201d which is used for servicing the IED by a \u201cFactory\u201d user."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-453",
              "description": "CWE-453 Insecure Default Variable Initialization",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-23T19:46:27.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE UR family insecure default variable initialization",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27426",
          "STATE": "PUBLIC",
          "TITLE": "GE UR family insecure default variable initialization"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UR family",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.1x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE UR IED firmware versions prior to version 8.1x with \u201cBasic\u201d security variant does not allow the disabling of the \u201cFactory Mode,\u201d which is used for servicing the IED by a \u201cFactory\u201d user."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-453 Insecure Default Variable Initialization"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
            },
            {
              "name": "https://www.gegridsolutions.com/Passport/Login.aspx",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27426",
    "datePublished": "2022-03-23T19:46:27.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:40:28.743Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27430 (GCVE-0-2021-27430)

Vulnerability from cvelistv5 – Published: 2022-03-23 19:46 – Updated: 2025-04-16 17:59
VLAI?
Title
GE UR family hardcoded credentials
Summary
GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
Impacted products
Vendor Product Version
GE UR bootloader binary Affected: 7.00
Affected: 7.01
Affected: 7.02
Create a notification for this product.
Credits
SCADA-X, DOE’s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:17.186Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-27430",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T17:30:50.880517Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T17:59:10.113Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UR bootloader binary",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "7.00"
            },
            {
              "status": "affected",
              "version": "7.01"
            },
            {
              "status": "affected",
              "version": "7.02"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798 Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-23T19:46:26.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE UR family hardcoded credentials",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27430",
          "STATE": "PUBLIC",
          "TITLE": "GE UR family hardcoded credentials"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UR bootloader binary",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "=",
                            "version_value": "7.00"
                          },
                          {
                            "version_value": "7.01"
                          },
                          {
                            "version_value": "7.02"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE UR bootloader binary Version 7.00, 7.01 and 7.02 included unused hardcoded credentials. Additionally, a user with physical access to the UR IED can interrupt the boot sequence by rebooting the UR."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 8.4,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798 Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
            },
            {
              "name": "https://www.gegridsolutions.com/Passport/Login.aspx",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27430",
    "datePublished": "2022-03-23T19:46:26.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T17:59:10.113Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27424 (GCVE-0-2021-27424)

Vulnerability from cvelistv5 – Published: 2022-03-23 19:46 – Updated: 2025-04-16 16:40
VLAI?
Title
GE UR family exposure of sensitive information to an unauthorized actor
Summary
GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a “Last-key pressed” MODBUS register can be used to gain unauthorized information.
CWE
Assigner
Impacted products
Vendor Product Version
GE UR family Affected: unspecified , < 8.1x (custom)
Create a notification for this product.
Credits
SCADA-X, DOE’s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:17.121Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-27424",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:59:10.663565Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:40:47.222Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UR family",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "8.1x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a \u201cLast-key pressed\u201d MODBUS register can be used to gain unauthorized information."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Information Exposure",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-23T19:46:25.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE UR family exposure of sensitive information to an unauthorized actor",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27424",
          "STATE": "PUBLIC",
          "TITLE": "GE UR family exposure of sensitive information to an unauthorized actor"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UR family",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.1x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE UR firmware versions prior to version 8.1x shares MODBUS memory map as part of the communications guide. GE was made aware a \u201cLast-key pressed\u201d MODBUS register can be used to gain unauthorized information."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-200 Information Exposure"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
            },
            {
              "name": "https://www.gegridsolutions.com/Passport/Login.aspx",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27424",
    "datePublished": "2022-03-23T19:46:25.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:40:47.222Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27428 (GCVE-0-2021-27428)

Vulnerability from cvelistv5 – Published: 2022-03-23 19:46 – Updated: 2025-04-16 16:40
VLAI?
Title
GE UR family Unrestricted Upload of File with Dangerous Type
Summary
GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool – Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10.
CWE
  • CWE-434 - Unrestricted Upload of File with Dangerous Type
Assigner
Impacted products
Vendor Product Version
GE UR family Affected: unspecified , < 8.1x (custom)
Create a notification for this product.
Credits
SCADA-X, DOE’s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:17.217Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-27428",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:57:46.786954Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:40:38.417Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UR family",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "8.1x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool \u2013 Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-434",
              "description": "CWE-434 Unrestricted Upload of File with Dangerous Type",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-23T19:46:25.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE UR family Unrestricted Upload of File with Dangerous Type",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27428",
          "STATE": "PUBLIC",
          "TITLE": "GE UR family Unrestricted Upload of File with Dangerous Type"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UR family",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.1x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE UR IED firmware versions prior to version 8.1x supports upgrading firmware using UR Setup configuration tool \u2013 Enervista UR Setup. This UR Setup tool validates the authenticity and integrity of firmware file before uploading the UR IED. An illegitimate user could upgrade firmware without appropriate privileges. The weakness is assessed, and mitigation is implemented in firmware Version 8.10."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-434 Unrestricted Upload of File with Dangerous Type"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
            },
            {
              "name": "https://www.gegridsolutions.com/Passport/Login.aspx",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27428",
    "datePublished": "2022-03-23T19:46:25.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:40:38.417Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27420 (GCVE-0-2021-27420)

Vulnerability from cvelistv5 – Published: 2022-03-23 19:46 – Updated: 2025-04-16 16:40
VLAI?
Title
GE UR family input validation
Summary
GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels.
CWE
  • CWE-20 - Improper Input Validation
Assigner
Impacted products
Vendor Product Version
GE UR family Affected: unspecified , < 8.1x (custom)
Create a notification for this product.
Credits
SCADA-X, DOE’s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:17.154Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-27420",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:59:13.965738Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:40:57.091Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UR family",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "8.1x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-23T19:46:24.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE UR family input validation",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27420",
          "STATE": "PUBLIC",
          "TITLE": "GE UR family input validation"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UR family",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.1x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE UR firmware versions prior to version 8.1x web server task does not properly handle receipt of unsupported HTTP verbs, resulting in the web server becoming temporarily unresponsive after receiving a series of unsupported HTTP requests. When unresponsive, the web server is inaccessible. By itself, this is not particularly significant as the relay remains effective in all other functionality and communication channels."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:L",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20 Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
            },
            {
              "name": "https://www.gegridsolutions.com/Passport/Login.aspx",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27420",
    "datePublished": "2022-03-23T19:46:24.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:40:57.091Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-27418 (GCVE-0-2021-27418)

Vulnerability from cvelistv5 – Published: 2022-03-23 19:46 – Updated: 2025-04-16 16:41
VLAI?
Title
GE UR family input validation
Summary
GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings.
CWE
  • CWE-20 - Improper Input Validation
Assigner
Impacted products
Vendor Product Version
GE UR family Affected: unspecified , < 8.1x (custom)
Create a notification for this product.
Credits
SCADA-X, DOE’s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T20:48:17.146Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2021-27418",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:59:16.984191Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:41:07.211Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "UR family",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "8.1x",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-23T19:46:23.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE UR family input validation",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2021-27418",
          "STATE": "PUBLIC",
          "TITLE": "GE UR family input validation"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "UR family",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "8.1x"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "SCADA-X, DOE\u2019s Cyber Testing for Resilient Industrial Control Systems (CyTRICS) program, Verve Industrial, and VuMetric reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE UR firmware versions prior to version 8.1x supports web interface with read-only access. The device fails to properly validate user input, making it possible to perform cross-site scripting attacks, which may be used to send a malicious script. Also, UR Firmware web server does not perform HTML encoding of user-supplied strings."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:L/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-20 Improper Input Validation"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-075-02"
            },
            {
              "name": "https://www.gegridsolutions.com/Passport/Login.aspx",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/Passport/Login.aspx"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users with impacted firmware versions update their UR devices to UR firmware Version 8.10, or greater to resolve these vulnerabilities. GE provides additional mitigations and information about these vulnerabilities in GE Publication Number: GES-2021-004 (login required)."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends protecting UR IED by using network defense-in-depth practices. This includes, but is not limited to, placing UR IED inside the control system network security perimeter, and having access controls, monitoring (such as an Intrusion Detection System), and other mitigating technologies in place. \n\nGE recommends users refer to the UR Deployment guide for secure configuration of UR IED and system."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2021-27418",
    "datePublished": "2022-03-23T19:46:23.000Z",
    "dateReserved": "2021-02-19T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:41:07.211Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-25193 (GCVE-0-2020-25193)

Vulnerability from cvelistv5 – Published: 2022-03-18 18:00 – Updated: 2025-04-16 16:41
VLAI?
Title
GE Reason RT43X Clocks Use of Hard-coded Cryptographic Key
Summary
By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection.
CWE
  • CWE-321 - Use of Hard-coded Cryptographic Key
Assigner
Impacted products
Vendor Product Version
GE Reason RT43X Clocks Affected: unspecified , < 08A06 (custom)
Create a notification for this product.
Credits
Tom Westenberg of Thales UK reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:26:10.063Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-005-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/app/DownloadFile.aspx?prod=RT430\u0026type=21\u0026file=5"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-25193",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:59:19.792538Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:41:25.123Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Reason RT43X Clocks",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "08A06",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Tom Westenberg of Thales UK reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 \u0026 RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-321",
              "description": "CWE-321 Use of Hard-coded Cryptographic Key",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T18:00:35.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-005-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/app/DownloadFile.aspx?prod=RT430\u0026type=21\u0026file=5"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users of Reason RT43X products update their units to firmware Version 08A06 or greater to resolve these issues. The firmware update addresses both vulnerabilities as described in the Reason RT43X 08A06 Release Notes.\n\nPlease see GE publication GES-2020-006 (login required) for more details on these issues."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE Reason RT43X Clocks Use of Hard-coded Cryptographic Key",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends users evaluate current risk and implement appropriate network security mitigation measures as follows. The following mitigation actions do not ensure complete security but should be considered until the affected time synchronization product is upgraded:\n    Use strong network and physical security protection to prevent an attacker from reaching the local network where Reason RT43X clocks are normally installed. \n    Block TCP/IP Ports 80 and 443 to block the HTTP/HTTPS access to web interface with Reason RT43X products, avoiding all the vulnerabilities. This TCP/IP port blocking should be limited to the Ethernet port interface where the Reason RT43X clock is connected (e.g., using Access Control List (ACL)). Otherwise, other HTTP/HTTPS applications may be affected.\n    Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet.\n    Analyze security events to early detect unexpected traffic/communication."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-25193",
          "STATE": "PUBLIC",
          "TITLE": "GE Reason RT43X Clocks Use of Hard-coded Cryptographic Key"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Reason RT43X Clocks",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "08A06"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Tom Westenberg of Thales UK reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "By having access to the hard-coded cryptographic key for GE Reason RT430, RT431 \u0026 RT434 GNSS clocks in firmware versions prior to version 08A06, attackers would be able to intercept and decrypt encrypted traffic through an HTTPS connection."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 5.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-321 Use of Hard-coded Cryptographic Key"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-005-03",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-005-03"
            },
            {
              "name": "https://www.gegridsolutions.com/app/DownloadFile.aspx?prod=RT430\u0026type=21\u0026file=5",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/app/DownloadFile.aspx?prod=RT430\u0026type=21\u0026file=5"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users of Reason RT43X products update their units to firmware Version 08A06 or greater to resolve these issues. The firmware update addresses both vulnerabilities as described in the Reason RT43X 08A06 Release Notes.\n\nPlease see GE publication GES-2020-006 (login required) for more details on these issues."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends users evaluate current risk and implement appropriate network security mitigation measures as follows. The following mitigation actions do not ensure complete security but should be considered until the affected time synchronization product is upgraded:\n    Use strong network and physical security protection to prevent an attacker from reaching the local network where Reason RT43X clocks are normally installed. \n    Block TCP/IP Ports 80 and 443 to block the HTTP/HTTPS access to web interface with Reason RT43X products, avoiding all the vulnerabilities. This TCP/IP port blocking should be limited to the Ethernet port interface where the Reason RT43X clock is connected (e.g., using Access Control List (ACL)). Otherwise, other HTTP/HTTPS applications may be affected.\n    Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet.\n    Analyze security events to early detect unexpected traffic/communication."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-25193",
    "datePublished": "2022-03-18T18:00:35.000Z",
    "dateReserved": "2020-09-04T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:41:25.123Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-25197 (GCVE-0-2020-25197)

Vulnerability from cvelistv5 – Published: 2022-03-18 18:00 – Updated: 2025-04-16 16:41
VLAI?
Title
GE Reason RT43X Clocks Code Injection
Summary
A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 & RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Impacted products
Vendor Product Version
GE Reason RT43X Clocks Affected: unspecified , < 08A06 (custom)
Create a notification for this product.
Credits
Tom Westenberg of Thales UK reported these vulnerabilities to GE.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T15:33:05.272Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-005-03"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/app/DownloadFile.aspx?prod=RT430\u0026type=21\u0026file=5"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2020-25197",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-04-16T15:57:49.847925Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-16T16:41:36.185Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Reason RT43X Clocks",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "08A06",
              "status": "affected",
              "version": "unspecified",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Tom Westenberg of Thales UK reported these vulnerabilities to GE."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 \u0026 RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2022-03-18T18:00:34.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-005-03"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://www.gegridsolutions.com/app/DownloadFile.aspx?prod=RT430\u0026type=21\u0026file=5"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "value": "GE strongly recommends users of Reason RT43X products update their units to firmware Version 08A06 or greater to resolve these issues. The firmware update addresses both vulnerabilities as described in the Reason RT43X 08A06 Release Notes.\n\nPlease see GE publication GES-2020-006 (login required) for more details on these issues."
        }
      ],
      "source": {
        "discovery": "EXTERNAL"
      },
      "title": "GE Reason RT43X Clocks Code Injection",
      "workarounds": [
        {
          "lang": "en",
          "value": "GE recommends users evaluate current risk and implement appropriate network security mitigation measures as follows. The following mitigation actions do not ensure complete security but should be considered until the affected time synchronization product is upgraded:\n    Use strong network and physical security protection to prevent an attacker from reaching the local network where Reason RT43X clocks are normally installed. \n    Block TCP/IP Ports 80 and 443 to block the HTTP/HTTPS access to web interface with Reason RT43X products, avoiding all the vulnerabilities. This TCP/IP port blocking should be limited to the Ethernet port interface where the Reason RT43X clock is connected (e.g., using Access Control List (ACL)). Otherwise, other HTTP/HTTPS applications may be affected.\n    Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet.\n    Analyze security events to early detect unexpected traffic/communication."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.0.9"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-25197",
          "STATE": "PUBLIC",
          "TITLE": "GE Reason RT43X Clocks Code Injection"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Reason RT43X Clocks",
                      "version": {
                        "version_data": [
                          {
                            "version_affected": "\u003c",
                            "version_value": "08A06"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": [
          {
            "lang": "eng",
            "value": "Tom Westenberg of Thales UK reported these vulnerabilities to GE."
          }
        ],
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A code injection vulnerability exists in one of the webpages in GE Reason RT430, RT431 \u0026 RT434 GNSS clocks in firmware versions prior to version 08A06 that could allow an authenticated remote attacker to execute arbitrary code on the system."
            }
          ]
        },
        "generator": {
          "engine": "Vulnogram 0.0.9"
        },
        "impact": {
          "cvss": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-94 Improper Control of Generation of Code (\u0027Code Injection\u0027)"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-005-03",
              "refsource": "CONFIRM",
              "url": "https://www.cisa.gov/uscert/ics/advisories/icsa-21-005-03"
            },
            {
              "name": "https://www.gegridsolutions.com/app/DownloadFile.aspx?prod=RT430\u0026type=21\u0026file=5",
              "refsource": "CONFIRM",
              "url": "https://www.gegridsolutions.com/app/DownloadFile.aspx?prod=RT430\u0026type=21\u0026file=5"
            }
          ]
        },
        "solution": [
          {
            "lang": "en",
            "value": "GE strongly recommends users of Reason RT43X products update their units to firmware Version 08A06 or greater to resolve these issues. The firmware update addresses both vulnerabilities as described in the Reason RT43X 08A06 Release Notes.\n\nPlease see GE publication GES-2020-006 (login required) for more details on these issues."
          }
        ],
        "source": {
          "discovery": "EXTERNAL"
        },
        "work_around": [
          {
            "lang": "en",
            "value": "GE recommends users evaluate current risk and implement appropriate network security mitigation measures as follows. The following mitigation actions do not ensure complete security but should be considered until the affected time synchronization product is upgraded:\n    Use strong network and physical security protection to prevent an attacker from reaching the local network where Reason RT43X clocks are normally installed. \n    Block TCP/IP Ports 80 and 443 to block the HTTP/HTTPS access to web interface with Reason RT43X products, avoiding all the vulnerabilities. This TCP/IP port blocking should be limited to the Ethernet port interface where the Reason RT43X clock is connected (e.g., using Access Control List (ACL)). Otherwise, other HTTP/HTTPS applications may be affected.\n    Minimize network exposure for all control system devices and/or systems and ensure they are not accessible from the Internet.\n    Analyze security events to early detect unexpected traffic/communication."
          }
        ]
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-25197",
    "datePublished": "2022-03-18T18:00:34.000Z",
    "dateReserved": "2020-09-04T00:00:00.000Z",
    "dateUpdated": "2025-04-16T16:41:36.185Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2021-31477 (GCVE-0-2021-31477)

Vulnerability from cvelistv5 – Published: 2021-06-16 22:15 – Updated: 2024-08-03 23:03
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852.
CWE
  • CWE-798 - Use of Hard-coded Credentials
Assigner
zdi
Impacted products
Vendor Product Version
GE Reason RPV311 Affected: 14A03
Create a notification for this product.
Credits
Anonymous
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-03T23:03:32.626Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-616/"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.gegridsolutions.com/products/support/GES-2021-005%20-%20RPV311%20Security%20Notice.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Reason RPV311",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "14A03"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "value": "Anonymous"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852."
        }
      ],
      "metrics": [
        {
          "cvssV3_0": {
            "attackComplexity": "LOW",
            "attackVector": "ADJACENT_NETWORK",
            "availabilityImpact": "LOW",
            "baseScore": 6.3,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "LOW",
            "integrityImpact": "LOW",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-798",
              "description": "CWE-798: Use of Hard-coded Credentials",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2021-06-29T14:33:46.000Z",
        "orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
        "shortName": "zdi"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-616/"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.gegridsolutions.com/products/support/GES-2021-005%20-%20RPV311%20Security%20Notice.pdf"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "zdi-disclosures@trendmicro.com",
          "ID": "CVE-2021-31477",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Reason RPV311",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "14A03"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "credit": "Anonymous",
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "This vulnerability allows remote attackers to execute arbitrary code on affected installations of GE Reason RPV311 14A03. Authentication is not required to exploit this vulnerability. The specific flaw exists within the firmware and filesystem of the device. The firmware and filesystem contain hard-coded default credentials. An attacker can leverage this vulnerability to execute code in the context of the download user. Was ZDI-CAN-11852."
            }
          ]
        },
        "impact": {
          "cvss": {
            "vectorString": "CVSS:3.0/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:L/A:L",
            "version": "3.0"
          }
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "CWE-798: Use of Hard-coded Credentials"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.zerodayinitiative.com/advisories/ZDI-21-616/",
              "refsource": "MISC",
              "url": "https://www.zerodayinitiative.com/advisories/ZDI-21-616/"
            },
            {
              "name": "https://www.gegridsolutions.com/products/support/GES-2021-005%20-%20RPV311%20Security%20Notice.pdf",
              "refsource": "MISC",
              "url": "https://www.gegridsolutions.com/products/support/GES-2021-005%20-%20RPV311%20Security%20Notice.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
    "assignerShortName": "zdi",
    "cveId": "CVE-2021-31477",
    "datePublished": "2021-06-16T22:15:21.000Z",
    "dateReserved": "2021-04-16T00:00:00.000Z",
    "dateUpdated": "2024-08-03T23:03:32.626Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2020-6977 (GCVE-0-2020-6977)

Vulnerability from cvelistv5 – Published: 2020-02-20 20:45 – Updated: 2024-08-04 09:18
VLAI?
Summary
A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5
Severity ?
No CVSS data available.
CWE
  • CWE-693 - PROTECTIONS MECHANISM FAILURE CWE-693
Assigner
References
Impacted products
Vendor Product Version
GE GE Ultrasound Products Affected: Vivid products - all versions
Affected: LOGIQ - all versions not including LOGIQ 100 Pro
Affected: Voluson - all versions
Affected: Versana Essential - all versions
Affected: Invenia ABUS Scan station - all versions
Affected: Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T09:18:03.015Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsma-20-049-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GE Ultrasound Products",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "Vivid products - all versions"
            },
            {
              "status": "affected",
              "version": "LOGIQ - all versions not including LOGIQ 100 Pro"
            },
            {
              "status": "affected",
              "version": "Voluson - all versions"
            },
            {
              "status": "affected",
              "version": "Versana Essential - all versions"
            },
            {
              "status": "affected",
              "version": "Invenia ABUS Scan station - all versions"
            },
            {
              "status": "affected",
              "version": "Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5"
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-693",
              "description": "PROTECTIONS MECHANISM FAILURE CWE-693",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2020-02-20T20:45:29.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsma-20-049-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2020-6977",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GE Ultrasound Products",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Vivid products - all versions"
                          },
                          {
                            "version_value": "LOGIQ - all versions not including LOGIQ 100 Pro"
                          },
                          {
                            "version_value": "Voluson - all versions"
                          },
                          {
                            "version_value": "Versana Essential - all versions"
                          },
                          {
                            "version_value": "Invenia ABUS Scan station - all versions"
                          },
                          {
                            "version_value": "Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A restricted desktop environment escape vulnerability exists in the Kiosk Mode functionality of affected devices. Specially crafted inputs can allow the user to escape the restricted environment, resulting in access to the underlying operating system. Affected devices include the following GE Ultrasound Products: Vivid products - all versions; LOGIQ - all versions not including LOGIQ 100 Pro; Voluson - all versions; Versana Essential - all versions; Invenia ABUS Scan station - all versions; Venue - all versions not including Venue 40 R1-3 and Venue 50 R4-5"
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "PROTECTIONS MECHANISM FAILURE CWE-693"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsma-20-049-02",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsma-20-049-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2020-6977",
    "datePublished": "2020-02-20T20:45:29.000Z",
    "dateReserved": "2020-01-14T00:00:00.000Z",
    "dateUpdated": "2024-08-04T09:18:03.015Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2019-10966 (GCVE-0-2019-10966)

Vulnerability from cvelistv5 – Published: 2019-07-10 17:52 – Updated: 2024-08-04 22:40
VLAI?
Summary
In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms.
Severity ?
No CVSS data available.
CWE
  • CWE-287 - IMPROPER AUTHENTICATION CWE-287
Assigner
References
Impacted products
Vendor Product Version
GE Aestiva and Aespire Affected: versions 7100
Affected: versions 7900
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-04T22:40:15.555Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "109102",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/109102"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://www.us-cert.gov/ics/advisories/icsma-19-190-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "Aestiva and Aespire",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "versions 7100"
            },
            {
              "status": "affected",
              "version": "versions 7900"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "IMPROPER AUTHENTICATION CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-07-10T17:52:39.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "109102",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/109102"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://www.us-cert.gov/ics/advisories/icsma-19-190-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2019-10966",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "Aestiva and Aespire",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "versions 7100"
                          },
                          {
                            "version_value": "versions 7900"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "In GE Aestiva and Aespire versions 7100 and 7900, a vulnerability exists where serial devices are connected via an added unsecured terminal server to a TCP/IP network configuration, which could allow an attacker to remotely modify device configuration and silence alarms."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER AUTHENTICATION CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "109102",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/109102"
            },
            {
              "name": "https://www.us-cert.gov/ics/advisories/icsma-19-190-01",
              "refsource": "MISC",
              "url": "https://www.us-cert.gov/ics/advisories/icsma-19-190-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2019-10966",
    "datePublished": "2019-07-10T17:52:23.000Z",
    "dateReserved": "2019-04-08T00:00:00.000Z",
    "dateUpdated": "2024-08-04T22:40:15.555Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-17925 (GCVE-0-2018-17925)

Vulnerability from cvelistv5 – Published: 2018-10-10 17:00 – Updated: 2024-09-16 23:25
VLAI?
Summary
Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted.
Severity ?
No CVSS data available.
CWE
  • CWE-623 - Unsafe ActiveX Control Marked Safe For Scripting CWE-623
Assigner
References
Impacted products
Vendor Product Version
GE iFix Affected: 2.0 - 5.0
Affected: 5.1
Affected: 5.5
Affected: 5.8
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:01:14.743Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "105540",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/105540"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "iFix",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "2.0 - 5.0"
            },
            {
              "status": "affected",
              "version": "5.1"
            },
            {
              "status": "affected",
              "version": "5.5"
            },
            {
              "status": "affected",
              "version": "5.8"
            }
          ]
        }
      ],
      "datePublic": "2018-10-09T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-623",
              "description": "Unsafe ActiveX Control Marked Safe For Scripting CWE-623",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-11T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "105540",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/105540"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-01"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-09T00:00:00",
          "ID": "CVE-2018-17925",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "iFix",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "2.0 - 5.0"
                          },
                          {
                            "version_value": "5.1"
                          },
                          {
                            "version_value": "5.5"
                          },
                          {
                            "version_value": "5.8"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple instances of this vulnerability (Unsafe ActiveX Control Marked Safe For Scripting) have been identified in the third-party ActiveX object provided to GE iFIX versions 2.0 - 5.8 by Gigasoft. Only the independent use of the Gigasoft charting package outside the iFIX product may expose users to the reported vulnerability. The reported method shown to impact Internet Explorer is not exposed in the iFIX product, nor is the core functionality of the iFIX product known to be impacted."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Unsafe ActiveX Control Marked Safe For Scripting CWE-623"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "105540",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/105540"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-282-01"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-17925",
    "datePublished": "2018-10-10T17:00:00.000Z",
    "dateReserved": "2018-10-02T00:00:00.000Z",
    "dateUpdated": "2024-09-16T23:25:32.834Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2017-7908 (GCVE-0-2017-7908)

Vulnerability from cvelistv5 – Published: 2018-10-02 21:00 – Updated: 2024-09-17 03:12
VLAI?
Summary
A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls.
Severity ?
No CVSS data available.
CWE
  • CWE-122 - HEAP-BASED BUFFER OVERFLOW CWE-122
Assigner
References
Impacted products
Vendor Product Version
GE GE Communicator Affected: Communicator 3.15 and prior.
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T16:19:29.259Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-275-02"
          },
          {
            "name": "99580",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/99580"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "GE Communicator",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "Communicator 3.15 and prior."
            }
          ]
        }
      ],
      "datePublic": "2018-10-02T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-122",
              "description": "HEAP-BASED BUFFER OVERFLOW CWE-122",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-10-03T09:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-275-02"
        },
        {
          "name": "99580",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/99580"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-10-02T00:00:00",
          "ID": "CVE-2017-7908",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "GE Communicator",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Communicator 3.15 and prior."
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "A heap-based buffer overflow exists in the third-party product Gigasoft, v5 and prior, included in GE Communicator 3.15 and prior. A malicious HTML file that loads the ActiveX controls can trigger the vulnerability via unchecked function calls."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "HEAP-BASED BUFFER OVERFLOW CWE-122"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-275-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-275-02"
            },
            {
              "name": "99580",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/99580"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2017-7908",
    "datePublished": "2018-10-02T21:00:00.000Z",
    "dateReserved": "2017-04-18T00:00:00.000Z",
    "dateUpdated": "2024-09-17T03:12:49.643Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-10615 (GCVE-0-2018-10615)

Vulnerability from cvelistv5 – Published: 2018-06-04 14:00 – Updated: 2024-09-16 23:51
VLAI?
Summary
Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform.
Severity ?
No CVSS data available.
CWE
  • CWE-23 - Relative path traversal CWE-23
Assigner
Impacted products
Vendor Product Version
GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:46:46.021Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "104377",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104377"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MDS PulseNET and MDS PulseNET Enterprise",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "Version 3.2.1 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "Relative path traversal CWE-23",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-05T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "104377",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104377"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-10615",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version 3.2.1 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Directory traversal may lead to files being exfiltrated or deleted on the GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior host platform."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Relative path traversal CWE-23"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "104377",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
              "refsource": "CONFIRM",
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10615",
    "datePublished": "2018-06-04T14:00:00.000Z",
    "dateReserved": "2018-05-01T00:00:00.000Z",
    "dateUpdated": "2024-09-16T23:51:13.413Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-10613 (GCVE-0-2018-10613)

Vulnerability from cvelistv5 – Published: 2018-06-04 14:00 – Updated: 2024-09-16 16:52
VLAI?
Summary
Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:46:46.243Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "104377",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104377"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MDS PulseNET and MDS PulseNET Enterprise",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "Version 3.2.1 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-611",
              "description": "XXE CWE-611",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-05T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "104377",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104377"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-10613",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version 3.2.1 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Multiple variants of XML External Entity (XXE) attacks may be used to exfiltrate data from the host Windows platform in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "XXE CWE-611"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "104377",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
              "refsource": "CONFIRM",
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10613",
    "datePublished": "2018-06-04T14:00:00.000Z",
    "dateReserved": "2018-05-01T00:00:00.000Z",
    "dateUpdated": "2024-09-16T16:52:57.226Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-10611 (GCVE-0-2018-10611)

Vulnerability from cvelistv5 – Published: 2018-06-04 14:00 – Updated: 2024-09-16 18:33
VLAI?
Summary
Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services.
Severity ?
No CVSS data available.
CWE
  • CWE-287 - Improper Authentication CWE-287
Assigner
Impacted products
Vendor Product Version
GE MDS PulseNET and MDS PulseNET Enterprise Affected: Version 3.2.1 and prior
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T07:46:46.151Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "name": "104377",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/104377"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "MDS PulseNET and MDS PulseNET Enterprise",
          "vendor": "GE",
          "versions": [
            {
              "status": "affected",
              "version": "Version 3.2.1 and prior"
            }
          ]
        }
      ],
      "datePublic": "2018-05-31T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "Improper Authentication CWE-287",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2018-06-05T09:57:01.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "name": "104377",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/104377"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2018-05-31T00:00:00",
          "ID": "CVE-2018-10611",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "MDS PulseNET and MDS PulseNET Enterprise",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "Version 3.2.1 and prior"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "GE"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "Java remote method invocation (RMI) input port in GE MDS PulseNET and MDS PulseNET Enterprise version 3.2.1 and prior may be exploited to allow unauthenticated users to launch applications and support remote code execution through web services."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "Improper Authentication CWE-287"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "104377",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/104377"
            },
            {
              "name": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1",
              "refsource": "CONFIRM",
              "url": "http://www.gegridsolutions.com/app/DownloadFile.aspx?prod=pulsenet\u0026type=9\u0026file=1"
            },
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-18-151-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-10611",
    "datePublished": "2018-06-04T14:00:00.000Z",
    "dateReserved": "2018-05-01T00:00:00.000Z",
    "dateUpdated": "2024-09-16T18:33:38.782Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2015-3976 (GCVE-0-2015-3976)

Vulnerability from cvelistv5 – Published: 2017-08-28 15:00 – Updated: 2025-11-04 23:33
VLAI?
Title
GE Multilink Cross-site Scripting
Summary
Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Multilink ML800/1200/1600/2400 Affected: 0 , ≤ 4.2.1 (custom)
Create a notification for this product.
Credits
Eireann Leverett of IOActive
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T06:04:02.453Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04A"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Multilink ML800/1200/1600/2400",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ML810/3000/3100 series switch",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "5.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eireann Leverett of IOActive"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003e\n\nCross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier.\n\n\u003c/p\u003e"
            }
          ],
          "value": "Cross-site scripting (XSS) vulnerability in GE Multilink ML810/3000/3100 series switch 5.2.0 and earlier, and GE Multilink ML800/1200/1600/2400 4.2.1 and earlier."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "SINGLE",
            "availabilityImpact": "NONE",
            "baseScore": 6.8,
            "confidentialityImpact": "NONE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:N/AC:L/Au:S/C:N/I:C/A:N",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-79",
              "description": "CWE-79",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T23:33:49.742Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-04",
        "discovery": "EXTERNAL"
      },
      "title": "GE Multilink Cross-site Scripting",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
            },
            {
              "name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2015-3976",
    "datePublished": "2017-08-28T15:00:00.000Z",
    "dateReserved": "2015-05-12T00:00:00.000Z",
    "dateUpdated": "2025-11-04T23:33:49.742Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-5409 (GCVE-0-2014-5409)

Vulnerability from cvelistv5 – Published: 2015-03-14 01:00 – Updated: 2025-11-03 18:58
VLAI?
Title
GE Hydran M2 Predictable Value Range from Previous Values
Summary
The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Hydran M2, containing the 17046 Ethernet option Affected: 0 , < October 2014 (custom)
Create a notification for this product.
Credits
Raheem Beyah, David Formby, and San Shin Jung of Georgia Tech
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.209Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-041-02"
          },
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "http://libraries.ge.com/download?fileid=642886573101\u0026entity_id=31955841101\u0026sid=101"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Hydran M2, containing the 17046 Ethernet option",
          "vendor": "GE",
          "versions": [
            {
              "lessThan": "October 2014",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Raheem Beyah, David Formby, and San Shin Jung of Georgia Tech"
        }
      ],
      "datePublic": "2015-03-10T06:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values.\u003c/p\u003e"
            }
          ],
          "value": "The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 6.4,
            "confidentialityImpact": "PARTIAL",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-343",
              "description": "CWE-343",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-03T18:58:26.900Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-041-02"
        },
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "http://libraries.ge.com/download?fileid=642886573101\u0026entity_id=31955841101\u0026sid=101"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-041-02.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "GE Digital Energy has released a new version of the Ethernet option, \nwhich resolves the identified vulnerability in newly released Hydran M2 \ndevices. The update changes the sequence algorithm, which makes it \nimprobable that a TCP sequence attack could succeed. The version of \nEthernet card that implements this improvement is \n94450214LFMT100SEM-L.R3-CL.\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE Digital Energy has released a new version of the Ethernet option, \nwhich resolves the identified vulnerability in newly released Hydran M2 \ndevices. The update changes the sequence algorithm, which makes it \nimprobable that a TCP sequence attack could succeed. The version of \nEthernet card that implements this improvement is \n94450214LFMT100SEM-L.R3-CL."
        }
      ],
      "source": {
        "advisory": "ICSA-15-041-02",
        "discovery": "EXTERNAL"
      },
      "title": "GE Hydran M2 Predictable Value Range from Previous Values",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThere is no method to update Hydran M2 devices released prior to \nOctober 2014. GE Digital Energy recommends that utilities using older \nversions of the Hydran M2 device implement network security defensive \nmeasures, to include the following:\u003c/p\u003e\n\u003cp\u003e\u2022 \u0026nbsp; \u0026nbsp; Place the Hydran M2 inside the control system network security perimeter with access controls and monitoring.\u003c/p\u003e\n\u003cp\u003e\u2022 \u0026nbsp; \u0026nbsp; Minimize network exposure to all other control system devices. \nControl system devices should not directly face the Internet or business\n networks.\u003c/p\u003e\n\u003cp\u003e\u2022 \u0026nbsp; \u0026nbsp; Locate control system networks and devices behind properly \nconfigured firewalls, and isolate them from the business network.\u003c/p\u003e\n\u003cp\u003e\u2022 \u0026nbsp; \u0026nbsp; When remote access is required, use secure methods, such as \nVirtual Private Networks (VPNs), recognizing that VPNs may have \nvulnerabilities and should be updated to the most current version \navailable. Also recognize that VPN is only as secure as the connected \ndevices.\u003c/p\u003e\n\u003cp\u003eGE Digital Energy\u2019s Product Bulletin is available in at the following location, with a user account:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://libraries.ge.com/download?fileid=642886573101\u0026amp;entity_id=31955841101\u0026amp;sid=101\"\u003ehttp://libraries.ge.com/download?fileid=642886573101\u0026amp;entity_id=31955841101\u0026amp;sid=101\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "There is no method to update Hydran M2 devices released prior to \nOctober 2014. GE Digital Energy recommends that utilities using older \nversions of the Hydran M2 device implement network security defensive \nmeasures, to include the following:\n\n\n\u2022 \u00a0 \u00a0 Place the Hydran M2 inside the control system network security perimeter with access controls and monitoring.\n\n\n\u2022 \u00a0 \u00a0 Minimize network exposure to all other control system devices. \nControl system devices should not directly face the Internet or business\n networks.\n\n\n\u2022 \u00a0 \u00a0 Locate control system networks and devices behind properly \nconfigured firewalls, and isolate them from the business network.\n\n\n\u2022 \u00a0 \u00a0 When remote access is required, use secure methods, such as \nVirtual Private Networks (VPNs), recognizing that VPNs may have \nvulnerabilities and should be updated to the most current version \navailable. Also recognize that VPN is only as secure as the connected \ndevices.\n\n\nGE Digital Energy\u2019s Product Bulletin is available in at the following location, with a user account:\n\n\n http://libraries.ge.com/download?fileid=642886573101\u0026entity_id=31955841101\u0026sid=101"
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5409",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The 17046 Ethernet card before 94450214LFMT100SEM-L.R3-CL for the GE Digital Energy Hydran M2 does not properly generate random values for TCP Initial Sequence Numbers (ISNs), which makes it easier for remote attackers to spoof packets by predicting these values."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-041-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-041-02"
            },
            {
              "name": "http://libraries.ge.com/download?fileid=642886573101\u0026entity_id=31955841101\u0026sid=101",
              "refsource": "MISC",
              "url": "http://libraries.ge.com/download?fileid=642886573101\u0026entity_id=31955841101\u0026sid=101"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5409",
    "datePublished": "2015-03-14T01:00:00.000Z",
    "dateReserved": "2014-08-22T00:00:00.000Z",
    "dateUpdated": "2025-11-03T18:58:26.900Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2"
}

CVE-2014-2355 (GCVE-0-2014-2355)

Vulnerability from cvelistv5 – Published: 2015-01-17 02:00 – Updated: 2025-10-03 17:01
VLAI?
Title
GE Proficy HMI/SCADA CIMPLICITY CimView
Summary
The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Proficy HMI/SCADA–CIMPLICITY Affected: 0 , ≤ 8.2 (custom)
Create a notification for this product.
Credits
Said Arfi
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T10:14:25.389Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Proficy HMI/SCADA\u2013CIMPLICITY",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "8.2",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Said Arfi"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eThe (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file.\u003c/p\u003e"
            }
          ],
          "value": "The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "MEDIUM",
            "accessVector": "LOCAL",
            "authentication": "SINGLE",
            "availabilityImpact": "COMPLETE",
            "baseScore": 6.6,
            "confidentialityImpact": "COMPLETE",
            "integrityImpact": "COMPLETE",
            "vectorString": "AV:L/AC:M/Au:S/C:C/I:C/A:C",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-119",
              "description": "CWE-119",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-10-03T17:01:02.978Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-14-289-02"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends that asset owners apply product updates to Proficy \nHMI/SCADA\u2013CIMPLICITY Versions 8.1 and 8.2. The following product updates\n address the memory access violation vulnerability:\u003c/p\u003e\u003cp\u003eProficy HMI/SCADA \u2013 CIMPLICITY 8.1 SIM 29 (DN4219) available at:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://support.ge-ip.com/support/index?page=dwchannel\u0026amp;id=DN4219\"\u003ehttp://support.ge-ip.com/support/index?page=dwchannel\u0026amp;id=DN4219\u003c/a\u003e\u003c/p\u003e\u003cp\u003eProficy HMI/SCADA\u2013CIMPLICITY 8.2 SIM 26 (DN4197) available at:\u0026nbsp;\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://support.ge-ip.com/support/index?page=dwchannel\u0026amp;id=DN4197\"\u003ehttp://support.ge-ip.com/support/index?page=dwchannel\u0026amp;id=DN4197\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends that asset owners apply product updates to Proficy \nHMI/SCADA\u2013CIMPLICITY Versions 8.1 and 8.2. The following product updates\n address the memory access violation vulnerability:\n\nProficy HMI/SCADA \u2013 CIMPLICITY 8.1 SIM 29 (DN4219) available at:\u00a0 http://support.ge-ip.com/support/index?page=dwchannel\u0026id=DN4219 \n\nProficy HMI/SCADA\u2013CIMPLICITY 8.2 SIM 26 (DN4197) available at:\u00a0 http://support.ge-ip.com/support/index?page=dwchannel\u0026id=DN4197"
        }
      ],
      "source": {
        "advisory": "ICSA-14-289-02",
        "discovery": "EXTERNAL"
      },
      "title": "GE Proficy HMI/SCADA CIMPLICITY CimView",
      "workarounds": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eIn cases where upgrading is not feasible, GE advises asset owners \nusing CIMPLICITY versions prior to 8.1 to consider using the following \nrecommendations that may mitigate or eliminate the impact of the \nvulnerability:\u003c/p\u003e\n\u003cul\u003e\n\u003cli\u003eTake steps to properly secure and protect stored CIMPLICITY screen files (.CIM).\u003c/li\u003e\n\u003cli\u003eAvoid using .CIM files received from unknown sources.\u003c/li\u003e\n\u003cli\u003eAvoid sending unprotected .CIM files over unencrypted networks or public Internet.\u003c/li\u003e\n\u003cli\u003eConsider using a strong hashing algorithm to validate integrity of \ncreated .CIM files and ensure they have not been tampered with over \ntime.\u003c/li\u003e\n\u003c/ul\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "In cases where upgrading is not feasible, GE advises asset owners \nusing CIMPLICITY versions prior to 8.1 to consider using the following \nrecommendations that may mitigate or eliminate the impact of the \nvulnerability:\n\n\n\n  *  Take steps to properly secure and protect stored CIMPLICITY screen files (.CIM).\n\n  *  Avoid using .CIM files received from unknown sources.\n\n  *  Avoid sending unprotected .CIM files over unencrypted networks or public Internet.\n\n  *  Consider using a strong hashing algorithm to validate integrity of \ncreated .CIM files and ensure they have not been tampered with over \ntime."
        }
      ],
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-2355",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "The (1) CimView and (2) CimEdit components in GE Proficy HMI/SCADA-CIMPLICITY 8.2 and earlier allow remote attackers to gain privileges via a crafted CIMPLICITY screen (aka .CIM) file."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-14-289-02"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-2355",
    "datePublished": "2015-01-17T02:00:00.000Z",
    "dateReserved": "2014-03-13T00:00:00.000Z",
    "dateUpdated": "2025-10-03T17:01:02.978Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2014-5418 (GCVE-0-2014-5418)

Vulnerability from cvelistv5 – Published: 2015-01-17 02:00 – Updated: 2025-11-04 23:30
VLAI?
Title
GE Multilink Uncontrolled Resource Consumption
Summary
GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets.
Severity ?
No CVSS data available.
CWE
Assigner
Impacted products
Vendor Product Version
GE Multilink ML800/1200/1600/2400 Affected: 0 , ≤ 4.2.1 (custom)
Create a notification for this product.
Credits
Eireann Leverett of IOActive
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-06T11:41:49.173Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
          },
          {
            "tags": [
              "x_refsource_CONFIRM",
              "x_transferred"
            ],
            "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Multilink ML800/1200/1600/2400",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "4.2.1",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ML810/3000/3100 series switch",
          "vendor": "GE",
          "versions": [
            {
              "lessThanOrEqual": "5.2.0",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Eireann Leverett of IOActive"
        }
      ],
      "datePublic": "2015-01-13T07:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets.\u003c/p\u003e"
            }
          ],
          "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
        }
      ],
      "metrics": [
        {
          "cvssV2_0": {
            "accessComplexity": "LOW",
            "accessVector": "NETWORK",
            "authentication": "NONE",
            "availabilityImpact": "PARTIAL",
            "baseScore": 5,
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
            "version": "2.0"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-400",
              "description": "CWE-400",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-11-04T23:30:32.557Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-15-013-04a"
        },
        {
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
        },
        {
          "url": "https://github.com/cisagov/CSAF/blob/develop/csaf_files/OT/white/2015/icsa-15-013-04a.json"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cp\u003eGE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n\u003ca target=\"_blank\" rel=\"nofollow\" href=\"http://www.gedigitalenergy.com\"\u003ehttp://www.gedigitalenergy.com\u003c/a\u003e. This firmware is also available through \nthe EnerVista Launchpad device management tool.\u003c/p\u003e\n\u003cp\u003eGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\u003c/p\u003e\n\u003cp\u003ePlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\u003c/p\u003e\n\u003cp\u003e\u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\"\u003ehttps://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf\u003c/a\u003e\u003c/p\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "GE recommends users update switch firmware to the \nlatest published version to resolve these vulnerabilities. The new \nfirmware will enable new keys to be calculated and exchanged, resolve \nthe slow data transfer and potential denial of service, and prevent the identified \ncross-site scripting vulnerabilities. The latest firmware is Version \n5.3.2 for the ML800, ML1200, ML1600 and ML2400 and Version 5.3.2-3K for \nthe ML810, ML3000, and ML3100. This firmware is available through the \n\u201cResources/Software\u201d link in the product web sites at \n http://www.gedigitalenergy.com . This firmware is also available through \nthe EnerVista Launchpad device management tool.\n\n\nGE recommends updating the switch over a serial connection to prevent an attacker from capturing the new key.\n\n\nPlease refer to the GE advisory for specific information on how to \ninstall the firmware and change RSA key. The GE advisory is available \nat:\n\n\n https://www.gedigitalenergy.com/products/support/multilink/MLSB0415.pdf"
        }
      ],
      "source": {
        "advisory": "ICSA-15-013-04",
        "discovery": "EXTERNAL"
      },
      "title": "GE Multilink Uncontrolled Resource Consumption",
      "x_generator": {
        "engine": "Vulnogram 0.5.0"
      },
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "ID": "CVE-2014-5418",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "n/a",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "n/a"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "n/a"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "GE Multilink ML800, ML1200, ML1600, and ML2400 switches with firmware 4.2.1 and earlier and Multilink ML810, ML3000, and ML3100 switches with firmware 5.2.0 and earlier allow remote attackers to cause a denial of service (resource consumption or reboot) via crafted packets."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "n/a"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-15-013-04"
            },
            {
              "name": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf",
              "refsource": "CONFIRM",
              "url": "http://www.gedigitalenergy.com/products/support/multilink/MLSB1214.pdf"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2014-5418",
    "datePublished": "2015-01-17T02:00:00.000Z",
    "dateReserved": "2014-08-22T00:00:00.000Z",
    "dateUpdated": "2025-11-04T23:30:32.557Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",