Search criteria

4 vulnerabilities by LCDS

CVE-2024-5040 (GCVE-0-2024-5040)

Vulnerability from cvelistv5 – Published: 2024-05-21 20:19 – Updated: 2024-08-01 21:03
VLAI?
Title
LCDS LAquis SCADA Path Traversal
Summary
There are multiple ways in LCDS LAquis SCADA for an attacker to access locations outside of their own directory.
CWE
Assigner
Impacted products
Vendor Product Version
LCDS LAquis SCADA Affected: 0 , ≤ 4.7.1.7 (custom)
Create a notification for this product.
Credits
Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:lcds:laquis_scada:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "laquis_scada",
            "vendor": "lcds",
            "versions": [
              {
                "status": "affected",
                "version": "*"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-5040",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-05-22T14:29:23.705386Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:02:51.586Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T21:03:10.607Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "LAquis SCADA",
          "vendor": "LCDS",
          "versions": [
            {
              "lessThanOrEqual": "4.7.1.7",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Natnael Samson working with Trend Micro Zero Day Initiative reported these vulnerabilities to CISA."
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nThere are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory.\n\n"
            }
          ],
          "value": "There are multiple ways in \nLCDS LAquis SCADA for an attacker to access locations outside of their own directory."
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "LOCAL",
            "baseScore": 8.5,
            "baseSeverity": "HIGH",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "PASSIVE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "HIGH",
            "vulnConfidentialityImpact": "HIGH",
            "vulnIntegrityImpact": "HIGH",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        },
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22 Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-05-21T20:19:19.456Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-142-01"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\nLCDS recommends users update to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://laquisscada.com/\"\u003eversion 4.7.1.371 or newer of LAquis SCADA.\u003c/a\u003e which has been configured to resolve the reported path traversal issues.\n\n\u003cbr\u003e"
            }
          ],
          "value": "LCDS recommends users update to  version 4.7.1.371 or newer of LAquis SCADA. https://laquisscada.com/  which has been configured to resolve the reported path traversal issues."
        }
      ],
      "source": {
        "advisory": "ICSA-24-142-01",
        "discovery": "EXTERNAL"
      },
      "title": "LCDS LAquis SCADA Path Traversal",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2024-5040",
    "datePublished": "2024-05-21T20:19:19.456Z",
    "dateReserved": "2024-05-16T23:41:33.314Z",
    "dateUpdated": "2024-08-01T21:03:10.607Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-19002 (GCVE-0-2018-19002)

Vulnerability from cvelistv5 – Published: 2019-02-05 18:00 – Updated: 2024-09-16 20:27
VLAI?
Summary
LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash.
Severity ?
No CVSS data available.
CWE
  • CWE-94 - IMPROPER CONTROL OF GENERATION OF CODE ('CODE INJECTION') CWE-94
Assigner
References
Impacted products
Vendor Product Version
LCDS LCDS Laquis SCADA Affected: All versions prior to version 4.1.0.4150
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:23:08.797Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
          },
          {
            "name": "106634",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106634"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LCDS Laquis SCADA",
          "vendor": "LCDS",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to version 4.1.0.4150"
            }
          ]
        }
      ],
      "datePublic": "2019-01-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-06T10:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "name": "106634",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-01-15T00:00:00",
          "ID": "CVE-2018-19002",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LCDS Laquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to version 4.1.0.4150"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows improper control of generation of code when opening a specially crafted project file, which may allow remote code execution, data exfiltration, or cause a system crash."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "IMPROPER CONTROL OF GENERATION OF CODE (\u0027CODE INJECTION\u0027) CWE-94"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
            },
            {
              "name": "106634",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106634"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-19002",
    "datePublished": "2019-02-05T18:00:00.000Z",
    "dateReserved": "2018-11-06T00:00:00.000Z",
    "dateUpdated": "2024-09-16T20:27:21.831Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-18986 (GCVE-0-2018-18986)

Vulnerability from cvelistv5 – Published: 2019-02-05 18:00 – Updated: 2024-09-17 00:17
VLAI?
Summary
LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution.
Severity ?
No CVSS data available.
CWE
  • CWE-787 - OUT-OF-BOUNDS WRITE CWE-787
Assigner
References
Impacted products
Vendor Product Version
LCDS LCDS Laquis SCADA Affected: All versions prior to version 4.1.0.4150
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:23:08.495Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
          },
          {
            "name": "106634",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106634"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LCDS Laquis SCADA",
          "vendor": "LCDS",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to version 4.1.0.4150"
            }
          ]
        }
      ],
      "datePublic": "2019-01-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-787",
              "description": "OUT-OF-BOUNDS WRITE CWE-787",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-06T10:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "name": "106634",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-01-15T00:00:00",
          "ID": "CVE-2018-18986",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LCDS Laquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to version 4.1.0.4150"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows the opening of a specially crafted report format file that may cause an out of bounds read, which may cause a system crash, allow data exfiltration, or remote code execution."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "OUT-OF-BOUNDS WRITE CWE-787"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
            },
            {
              "name": "106634",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106634"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-18986",
    "datePublished": "2019-02-05T18:00:00.000Z",
    "dateReserved": "2018-11-06T00:00:00.000Z",
    "dateUpdated": "2024-09-17T00:17:11.349Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2018-19029 (GCVE-0-2018-19029)

Vulnerability from cvelistv5 – Published: 2019-02-05 18:00 – Updated: 2024-09-16 22:25
VLAI?
Summary
LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash.
Severity ?
No CVSS data available.
CWE
  • CWE-822 - UNTRUSTED POINTER DEREFERENCE CWE-822
Assigner
References
Impacted products
Vendor Product Version
LCDS LCDS Laquis SCADA Affected: All versions prior to version 4.1.0.4150
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-05T11:23:08.951Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_refsource_MISC",
              "x_transferred"
            ],
            "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
          },
          {
            "name": "106634",
            "tags": [
              "vdb-entry",
              "x_refsource_BID",
              "x_transferred"
            ],
            "url": "http://www.securityfocus.com/bid/106634"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "LCDS Laquis SCADA",
          "vendor": "LCDS",
          "versions": [
            {
              "status": "affected",
              "version": "All versions prior to version 4.1.0.4150"
            }
          ]
        }
      ],
      "datePublic": "2019-01-15T00:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash."
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-822",
              "description": "UNTRUSTED POINTER DEREFERENCE CWE-822",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2019-02-06T10:57:02.000Z",
        "orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
        "shortName": "icscert"
      },
      "references": [
        {
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
        },
        {
          "name": "106634",
          "tags": [
            "vdb-entry",
            "x_refsource_BID"
          ],
          "url": "http://www.securityfocus.com/bid/106634"
        }
      ],
      "x_legacyV4Record": {
        "CVE_data_meta": {
          "ASSIGNER": "ics-cert@hq.dhs.gov",
          "DATE_PUBLIC": "2019-01-15T00:00:00",
          "ID": "CVE-2018-19029",
          "STATE": "PUBLIC"
        },
        "affects": {
          "vendor": {
            "vendor_data": [
              {
                "product": {
                  "product_data": [
                    {
                      "product_name": "LCDS Laquis SCADA",
                      "version": {
                        "version_data": [
                          {
                            "version_value": "All versions prior to version 4.1.0.4150"
                          }
                        ]
                      }
                    }
                  ]
                },
                "vendor_name": "LCDS"
              }
            ]
          }
        },
        "data_format": "MITRE",
        "data_type": "CVE",
        "data_version": "4.0",
        "description": {
          "description_data": [
            {
              "lang": "eng",
              "value": "LCDS Laquis SCADA prior to version 4.1.0.4150 allows an attacker using a specially crafted project file to supply a pointer for a controlled memory address, which may allow remote code execution, data exfiltration, or cause a system crash."
            }
          ]
        },
        "problemtype": {
          "problemtype_data": [
            {
              "description": [
                {
                  "lang": "eng",
                  "value": "UNTRUSTED POINTER DEREFERENCE CWE-822"
                }
              ]
            }
          ]
        },
        "references": {
          "reference_data": [
            {
              "name": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01",
              "refsource": "MISC",
              "url": "https://ics-cert.us-cert.gov/advisories/ICSA-19-015-01"
            },
            {
              "name": "106634",
              "refsource": "BID",
              "url": "http://www.securityfocus.com/bid/106634"
            }
          ]
        }
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
    "assignerShortName": "icscert",
    "cveId": "CVE-2018-19029",
    "datePublished": "2019-02-05T18:00:00.000Z",
    "dateReserved": "2018-11-06T00:00:00.000Z",
    "dateUpdated": "2024-09-16T22:25:18.489Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}