CVE-2024-38435 (GCVE-0-2024-38435)

Vulnerability from cvelistv5 – Published: 2024-07-21 07:10 – Updated: 2024-08-02 04:12
VLAI?
Title
Unitronics Vision PLC - CWE-703: Improper Check or Handling of Exceptional Conditions
Summary
Unitronics Vision PLC – CWE-703: Improper Check or Handling of Exceptional Conditions may allow denial of service
CWE
  • CWE-703 - Improper Check or Handling of Exceptional Conditions
Assigner
Impacted products
Vendor Product Version
Unitronics Vision PLC Affected: All versions , < Upgrade to v9.9.1 (custom)
Create a notification for this product.
Credits
Claroty Research – Team 82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-38435",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-22T11:51:46.970559Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-22T11:51:57.805Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T04:12:24.743Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Vision PLC",
          "vendor": "Unitronics",
          "versions": [
            {
              "lessThan": "Upgrade to v9.9.1",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Claroty Research \u2013 Team 82"
        }
      ],
      "datePublic": "2024-07-18T07:05:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Vision PLC \u2013\u0026nbsp;\u003c/span\u003eCWE-703: Improper Check or Handling of Exceptional Conditions may allow denial of service\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u003cp\u003e\u0026nbsp;\u003c/p\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "Unitronics Vision PLC \u2013\u00a0CWE-703: Improper Check or Handling of Exceptional Conditions may allow denial of service"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "NONE",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-703",
              "description": "CWE-703: Improper Check or Handling of Exceptional Conditions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-21T07:10:04.460Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to v9.9.1\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v9.9.1"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0173",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Vision PLC - CWE-703: Improper Check or Handling of Exceptional Conditions",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-38435",
    "datePublished": "2024-07-21T07:10:04.460Z",
    "dateReserved": "2024-06-16T08:00:52.286Z",
    "dateUpdated": "2024-08-02T04:12:24.743Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-38434 (GCVE-0-2024-38434)

Vulnerability from cvelistv5 – Published: 2024-07-21 07:08 – Updated: 2024-08-02 04:12
VLAI?
Title
Unitronics Vision PLC - CWE-676: Use of Potentially Dangerous Function
Summary
Unitronics Vision PLC – CWE-676: Use of Potentially Dangerous Function may allow security feature bypass
CWE
  • CWE-676 - Use of Potentially Dangerous Function
Assigner
Impacted products
Vendor Product Version
Unitronics Vision PLC Affected: All versions , < Upgrade to v9.9.1 (custom)
Create a notification for this product.
Credits
Claroty Research – Team 82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-38434",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-07-29T14:56:41.036778Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-29T14:56:57.915Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T04:12:24.698Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Vision PLC",
          "vendor": "Unitronics",
          "versions": [
            {
              "lessThan": "Upgrade to v9.9.1",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Claroty Research \u2013 Team 82"
        }
      ],
      "datePublic": "2024-07-18T07:05:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Vision PLC \u2013  \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCWE-676: Use of Potentially Dangerous Function\u003c/span\u003e\u003cb\u003e\u0026nbsp;\u003c/b\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003emay allow security feature bypass\u003c/span\u003e\n\n\u003c/span\u003e"
            }
          ],
          "value": "Unitronics Vision PLC \u2013  \n\nCWE-676: Use of Potentially Dangerous Function\u00a0may allow security feature bypass"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 6.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-676",
              "description": "CWE-676: Use of Potentially Dangerous Function",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-21T07:08:52.056Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/Departments/faq/cve_advisories"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to v9.9.1\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "Upgrade to v9.9.1"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0172",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Vision PLC - CWE-676: Use of Potentially Dangerous Function",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-38434",
    "datePublished": "2024-07-21T07:08:52.056Z",
    "dateReserved": "2024-06-16T08:00:52.285Z",
    "dateUpdated": "2024-08-02T04:12:24.698Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-1480 (GCVE-0-2024-1480)

Vulnerability from cvelistv5 – Published: 2024-04-19 21:19 – Updated: 2024-08-01 18:40
VLAI?
Title
Unitronics Vision Standard Unauthenticated Password Retrieval
Summary
Unitronics Vision Standard line of controllers allow the Information Mode password to be retrieved without authentication.
CWE
  • CWE-257 - Storing Passwords in a Recoverable Format
Assigner
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-1480",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-04-20T19:55:11.495288Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-07-23T18:46:06.919Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:40:21.234Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-109-01"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.dragos.com/advisory/unitronics-vision-standard/"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "affected",
          "product": "Vision230",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Vision280",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Vision290",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Vision530",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "Vision120",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "0"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Unitronics Vision Standard line of controllers allow the Information Mode password to be retrieved without authentication."
            }
          ],
          "value": "Unitronics Vision Standard line of controllers allow the Information Mode password to be retrieved without authentication."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-114",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-114 Authentication Abuse"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "NONE",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-257",
              "description": "CWE-257 Storing Passwords in a Recoverable Format",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-04-19T21:19:27.592Z",
        "orgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
        "shortName": "Dragos"
      },
      "references": [
        {
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-24-109-01"
        },
        {
          "url": "https://www.dragos.com/advisory/unitronics-vision-standard/"
        }
      ],
      "source": {
        "discovery": "INTERNAL"
      },
      "title": "Unitronics Vision Standard Unauthenticated Password Retrieval",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "12bdf821-1545-4a87-aac5-61670cc6fcef",
    "assignerShortName": "Dragos",
    "cveId": "CVE-2024-1480",
    "datePublished": "2024-04-19T21:19:27.592Z",
    "dateReserved": "2024-02-13T18:49:36.966Z",
    "dateUpdated": "2024-08-01T18:40:21.234Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27774 (GCVE-0-2024-27774)

Vulnerability from cvelistv5 – Published: 2024-03-18 13:34 – Updated: 2024-08-02 00:41
VLAI?
Title
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-259: Use of Hard-coded Password
Summary
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-259: Use of Hard-coded Password may allow disclosing Sensitive Information Embedded inside Device's Firmware
CWE
  • CWE-259 - Use of Hard-coded Password
Assigner
Impacted products
Vendor Product Version
Unitronics Unistream Unilogic Affected: All versions , < 1.35.227 (custom)
Create a notification for this product.
Credits
Noam Moshe, Vera Mens of Claroty Team82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unistream_unilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "1.35.227",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27774",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-06-20T21:32:07.422871Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T21:32:26.836Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:54.444Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unistream Unilogic",
          "vendor": "Unitronics ",
          "versions": [
            {
              "lessThan": "1.35.227",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe, Vera Mens of Claroty Team82"
        }
      ],
      "datePublic": "2024-03-18T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 -\n\n\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCWE-259: Use of Hard-coded Password may allow disclosing Sensitive Information Embedded inside Device\u0027s Firmware\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\n\n\n\n\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 -\n\nCWE-259: Use of Hard-coded Password may allow disclosing Sensitive Information Embedded inside Device\u0027s Firmware\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "HIGH",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 7.5,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-259",
              "description": "CWE-259: Use of Hard-coded Password",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T13:34:31.538Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        },
        {
          "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 1.35.227 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 1.35.227 or later.\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0154",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Unistream Unilogic \u2013 Versions prior to 1.35.227  CWE-259: Use of Hard-coded Password",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-27774",
    "datePublished": "2024-03-18T13:34:31.538Z",
    "dateReserved": "2024-02-26T09:27:55.323Z",
    "dateUpdated": "2024-08-02T00:41:54.444Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27773 (GCVE-0-2024-27773)

Vulnerability from cvelistv5 – Published: 2024-03-18 13:32 – Updated: 2024-08-02 00:41
VLAI?
Title
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-348: Use of Less Trusted Source
Summary
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-348: Use of Less Trusted Source may allow RCE
CWE
  • CWE-348 - Use of Less Trusted Source
Assigner
Impacted products
Vendor Product Version
Unitronics Unistream Unilogic Affected: All versions , < 1.35.227 (custom)
Create a notification for this product.
Credits
Noam Moshe, Vera Mens of Claroty Team82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unistream_unilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "1.35.227",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27773",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-21T15:33:05.323875Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T21:27:28.047Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:54.422Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unistream Unilogic",
          "vendor": "Unitronics ",
          "versions": [
            {
              "lessThan": "1.35.227",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe, Vera Mens of Claroty Team82"
        }
      ],
      "datePublic": "2024-03-18T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 -\n\n\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCWE-348: Use of Less Trusted Source may allow RCE\u003c/span\u003e\n\n\u003c/span\u003e\n\n\n\n\n\n\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 -\n\nCWE-348: Use of Less Trusted Source may allow RCE\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-348",
              "description": "CWE-348: Use of Less Trusted Source",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T13:32:46.698Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        },
        {
          "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 1.35.227 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 1.35.227 or later.\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0153",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Unistream Unilogic \u2013 Versions prior to 1.35.227  CWE-348: Use of Less Trusted Source",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-27773",
    "datePublished": "2024-03-18T13:32:46.698Z",
    "dateReserved": "2024-02-26T09:27:55.323Z",
    "dateUpdated": "2024-08-02T00:41:54.422Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27772 (GCVE-0-2024-27772)

Vulnerability from cvelistv5 – Published: 2024-03-18 13:28 – Updated: 2024-08-02 00:41
VLAI?
Title
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-78: 'OS Command Injection'
Summary
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-78: 'OS Command Injection' may allow RCE
CWE
  • CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
Impacted products
Vendor Product Version
Unitronics Unistream Unilogic Affected: All versions , < 1.35.227 (custom)
Create a notification for this product.
Credits
Noam Moshe, Vera Mens of Claroty Team82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unistream_unilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "1.35.227",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27772",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T18:06:12.435070Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T21:22:58.597Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:54.441Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unistream Unilogic",
          "vendor": "Unitronics ",
          "versions": [
            {
              "lessThan": "1.35.227",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe, Vera Mens of Claroty Team82"
        }
      ],
      "datePublic": "2024-03-18T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 -\n\n\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCWE-78: \u0027OS Command Injection\u0027 may allow RCE\u003c/span\u003e\n\n\n\n\n\n\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 -\n\nCWE-78: \u0027OS Command Injection\u0027 may allow RCE\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-78",
              "description": "CWE-78 Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T13:28:35.731Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        },
        {
          "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 1.35.227 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 1.35.227 or later.\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0152",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Unistream Unilogic \u2013 Versions prior to 1.35.227  CWE-78: \u0027OS Command Injection\u0027",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-27772",
    "datePublished": "2024-03-18T13:28:35.731Z",
    "dateReserved": "2024-02-26T09:27:55.323Z",
    "dateUpdated": "2024-08-02T00:41:54.441Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27771 (GCVE-0-2024-27771)

Vulnerability from cvelistv5 – Published: 2024-03-18 13:27 – Updated: 2024-08-02 00:41
VLAI?
Title
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-22: 'Path Traversal'
Summary
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-22: 'Path Traversal' may allow RCE
CWE
Assigner
Impacted products
Vendor Product Version
Unitronics Unistream Unilogic Affected: All versions , < 1.35.227 (custom)
Create a notification for this product.
Credits
Noam Moshe, Vera Mens of Claroty Team82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unistream_unilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "1.35.227",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27771",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T18:20:07.973933Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T21:24:27.361Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:54.438Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unistream Unilogic",
          "vendor": "Unitronics ",
          "versions": [
            {
              "lessThan": "1.35.227",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe, Vera Mens of Claroty Team82"
        }
      ],
      "datePublic": "2024-03-18T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 -\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCWE-22: \u0027Path Traversal\u0027\u003c/span\u003e\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\u0026nbsp;may allow RCE\u003c/span\u003e\n\n\n\n\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 -\n\nCWE-22: \u0027Path Traversal\u0027\u00a0may allow RCE\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: \u0027Path Traversal\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T13:27:39.449Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        },
        {
          "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 1.35.227 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 1.35.227 or later.\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0151",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Unistream Unilogic \u2013 Versions prior to 1.35.227  CWE-22: \u0027Path Traversal\u0027",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-27771",
    "datePublished": "2024-03-18T13:27:39.449Z",
    "dateReserved": "2024-02-26T09:27:55.323Z",
    "dateUpdated": "2024-08-02T00:41:54.438Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27770 (GCVE-0-2024-27770)

Vulnerability from cvelistv5 – Published: 2024-03-18 13:23 – Updated: 2024-08-02 00:41
VLAI?
Title
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-23: Relative Path Traversal
Summary
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-23: Relative Path Traversal
CWE
  • CWE-23 - Relative Path Traversal
Assigner
Impacted products
Vendor Product Version
Unitronics Unistream Unilogic Affected: All versions , < 1.35.227 (custom)
Create a notification for this product.
Credits
Noam Moshe, Vera Mens of Claroty Team82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unistream_unilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "1.35.227",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27770",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T18:20:07.973933Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T21:25:03.972Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:54.287Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unistream Unilogic",
          "vendor": "Unitronics ",
          "versions": [
            {
              "lessThan": "1.35.227",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe, Vera Mens of Claroty Team82"
        }
      ],
      "datePublic": "2024-03-18T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 - \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCWE-23: Relative Path Traversal\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 - \n\nCWE-23: Relative Path Traversal\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-23",
              "description": "CWE-23: Relative Path Traversal",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T13:23:31.838Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        },
        {
          "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 1.35.227 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 1.35.227 or later.\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0150",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Unistream Unilogic \u2013 Versions prior to 1.35.227  CWE-23: Relative Path Traversal",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-27770",
    "datePublished": "2024-03-18T13:23:31.838Z",
    "dateReserved": "2024-02-26T09:27:55.323Z",
    "dateUpdated": "2024-08-02T00:41:54.287Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27769 (GCVE-0-2024-27769)

Vulnerability from cvelistv5 – Published: 2024-03-18 13:21 – Updated: 2025-04-10 20:24
VLAI?
Title
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-200: Exposure of Sensitive Information to an Unauthorized Actor
Summary
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-200: Exposure of Sensitive Information to an Unauthorized Actor may allow Taking Ownership Over Devices
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
Impacted products
Vendor Product Version
Unitronics Unistream Unilogic Affected: All versions , < 1.35.227 (custom)
Create a notification for this product.
Credits
Noam Moshe, Vera Mens of Claroty Team82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unistream_unilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "1.35.227",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27769",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-19T14:35:02.996286Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-04-10T20:24:59.561Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:54.428Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unistream Unilogic",
          "vendor": "Unitronics ",
          "versions": [
            {
              "lessThan": "1.35.227",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe, Vera Mens of Claroty Team82"
        }
      ],
      "datePublic": "2024-03-18T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 - \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCWE-200: Exposure of Sensitive Information to an Unauthorized Actor may allow Taking Ownership Over Devices\u003c/span\u003e\n\n\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 - \n\nCWE-200: Exposure of Sensitive Information to an Unauthorized Actor may allow Taking Ownership Over Devices\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 8.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T13:21:17.800Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        },
        {
          "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 1.35.227 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 1.35.227 or later.\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0149",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Unistream Unilogic \u2013 Versions prior to 1.35.227  CWE-200: Exposure of Sensitive Information to an Unauthorized Actor",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-27769",
    "datePublished": "2024-03-18T13:21:17.800Z",
    "dateReserved": "2024-02-26T09:27:55.322Z",
    "dateUpdated": "2025-04-10T20:24:59.561Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27768 (GCVE-0-2024-27768)

Vulnerability from cvelistv5 – Published: 2024-03-18 13:19 – Updated: 2024-08-02 00:41
VLAI?
Title
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-22: 'Path Traversal'
Summary
Unitronics Unistream Unilogic – Versions prior to 1.35.227 - CWE-22: 'Path Traversal' may allow RCE
CWE
Assigner
Impacted products
Vendor Product Version
Unitronics Unistream Unilogic Affected: All versions , < 1.35.227 (custom)
Create a notification for this product.
Credits
Noam Moshe, Vera Mens of Claroty Team82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unistream_unilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "1.35.227",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27768",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T18:20:07.973933Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T21:26:07.259Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:54.285Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unistream Unilogic",
          "vendor": "Unitronics ",
          "versions": [
            {
              "lessThan": "1.35.227",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe, Vera Mens of Claroty Team82"
        }
      ],
      "datePublic": "2024-03-18T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003e\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 - CWE-22: \u0027Path Traversal\u0027 may allow RCE\u003c/span\u003e\n\n\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nUnitronics Unistream Unilogic \u2013 Versions prior to 1.35.227 - CWE-22: \u0027Path Traversal\u0027 may allow RCE\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-22",
              "description": "CWE-22: \u0027Path Traversal\u0027",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T13:19:49.735Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        },
        {
          "url": "https://claroty.com/team82/blog/new-critical-vulnerabilities-in-unitronics-unistream-devices-uncovered"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 1.35.227 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 1.35.227 or later.\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0148",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Unistream Unilogic \u2013 Versions prior to 1.35.227  CWE-22: \u0027Path Traversal\u0027",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-27768",
    "datePublished": "2024-03-18T13:19:49.735Z",
    "dateReserved": "2024-02-26T09:27:55.322Z",
    "dateUpdated": "2024-08-02T00:41:54.285Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2024-27767 (GCVE-0-2024-27767)

Vulnerability from cvelistv5 – Published: 2024-03-18 13:13 – Updated: 2024-08-02 00:41
VLAI?
Title
Unitronics Unistream Unilogic – Versions prior to 1.35.227 CWE-287: Improper Authentication
Summary
CWE-287: Improper Authentication may allow Authentication Bypass
CWE
  • CWE-287 - Improper Authentication
Assigner
Impacted products
Vendor Product Version
Unitronics Unistream Unilogic Affected: All versions , < 1.35.227 (custom)
Create a notification for this product.
Credits
Noam Moshe, Vera Mens of Claroty Team82
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:unistream_unilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "unistream_unilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "1.35.227",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-27767",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-03-18T18:22:57.969128Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-20T21:26:31.866Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T00:41:54.434Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Unistream Unilogic",
          "vendor": "Unitronics ",
          "versions": [
            {
              "lessThan": "1.35.227",
              "status": "affected",
              "version": "All versions",
              "versionType": "custom"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Noam Moshe, Vera Mens of Claroty Team82"
        }
      ],
      "datePublic": "2024-03-18T14:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eCWE-287: Improper Authentication may allow Authentication Bypass\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nCWE-287: Improper Authentication may allow Authentication Bypass\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 10,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-287",
              "description": "CWE-287 Improper Authentication",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-03-18T13:13:36.868Z",
        "orgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
        "shortName": "INCD"
      },
      "references": [
        {
          "url": "https://www.gov.il/en/departments/dynamiccollectors/cve_advisories_listing?skip=0"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eUpgrade to version 1.35.227 or later.\u003c/span\u003e\n\n\u003cbr\u003e"
            }
          ],
          "value": "\nUpgrade to version 1.35.227 or later.\n\n"
        }
      ],
      "source": {
        "advisory": "ILVN-2024-0147",
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics Unistream Unilogic \u2013 Versions prior to 1.35.227  CWE-287: Improper Authentication",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a57ee1ae-c9c1-4f40-aa7b-cf10760fde3f",
    "assignerShortName": "INCD",
    "cveId": "CVE-2024-27767",
    "datePublished": "2024-03-18T13:13:36.868Z",
    "dateReserved": "2024-02-26T09:27:55.322Z",
    "dateUpdated": "2024-08-02T00:41:54.434Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-6448 (GCVE-0-2023-6448)

Vulnerability from cvelistv5 – Published: 2023-12-05 17:43 – Updated: 2025-10-21 23:05
VLAI?
Title
Unitronics VisiLogic uses a default administrative password
Summary
Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.
CWE
  • CWE-1188 - Insecure Default Initialization of Resource
Assigner
Impacted products
Vendor Product Version
Unitronics VisiLogic Affected: 0 , < 9.9.00 (custom)
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T08:28:21.839Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems"
          },
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.unitronicsplc.com/cyber_security_vision-samba/"
          },
          {
            "tags": [
              "release-notes",
              "x_transferred"
            ],
            "url": "https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf"
          },
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:a:unitronics:visilogic:*:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unknown",
            "product": "visilogic",
            "vendor": "unitronics",
            "versions": [
              {
                "lessThan": "9.9.00",
                "status": "affected",
                "version": "0",
                "versionType": "custom"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-6448",
                "options": [
                  {
                    "Exploitation": "active"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2023-12-06T14:07:21.216497Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          },
          {
            "other": {
              "content": {
                "dateAdded": "2023-12-11",
                "reference": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"
              },
              "type": "kev"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-10-21T23:05:30.290Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "government-resource"
            ],
            "url": "https://www.cisa.gov/known-exploited-vulnerabilities-catalog?field_cve=CVE-2023-6448"
          }
        ],
        "timeline": [
          {
            "lang": "en",
            "time": "2023-12-11T00:00:00+00:00",
            "value": "CVE-2023-6448 added to CISA KEV"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "VisiLogic",
          "vendor": "Unitronics",
          "versions": [
            {
              "lessThan": "9.9.00",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "datePublic": "2023-11-28T05:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.\u003cbr\u003e"
            }
          ],
          "value": "Unitronics VisiLogic before version 9.9.00, used in Vision and Samba PLCs and HMIs, uses a default administrative password. An unauthenticated attacker with network access can take administrative control of a vulnerable system.\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.8,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-1188",
              "description": "CWE-1188 Insecure Default Initialization of Resource",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-12-19T16:23:39.022Z",
        "orgId": "9119a7d8-5eab-497f-8521-727c672e3725",
        "shortName": "cisa-cg"
      },
      "references": [
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/alerts/2023/11/28/exploitation-unitronics-plcs-used-water-and-wastewater-systems"
        },
        {
          "url": "https://www.unitronicsplc.com/cyber_security_vision-samba/"
        },
        {
          "tags": [
            "release-notes"
          ],
          "url": "https://downloads.unitronicsplc.com/Sites/plc/Visilogic/Version_Changes-Bug_Reports/VisiLogic%209.9.00%20Version%20changes.pdf"
        },
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://downloads.unitronicsplc.com/Sites/plc/Technical_Library/Unitronics-Cybersecurity-Advisory-2023-001-CVE-2023-6448.pdf"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Unitronics VisiLogic uses a default administrative password",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "9119a7d8-5eab-497f-8521-727c672e3725",
    "assignerShortName": "cisa-cg",
    "cveId": "CVE-2023-6448",
    "datePublished": "2023-12-05T17:43:40.451Z",
    "dateReserved": "2023-11-30T18:40:51.463Z",
    "dateUpdated": "2025-10-21T23:05:30.290Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}

CVE-2023-2003 (GCVE-0-2023-2003)

Vulnerability from cvelistv5 – Published: 2023-07-13 11:25 – Updated: 2024-10-30 16:04
VLAI?
Title
Embedded malicious code vulnerability in Unitronics Vision1210
Summary
Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device's data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.
CWE
  • CWE-506 - Embedded Malicious Code
Assigner
Impacted products
Vendor Product Version
Unitronics Vision1210 Affected: 4.3, build 5
Create a notification for this product.
Credits
Carlos Antonini Cepeda
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T06:05:27.093Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/embedded-malicious-code-vulnerability-unitronics-vision1210"
          },
          {
            "tags": [
              "related",
              "technical-description",
              "x_transferred"
            ],
            "url": "https://www.hackplayers.com/2023/07/vulnerabilidad-vision1210-unitronics.html"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "affected": [
          {
            "cpes": [
              "cpe:2.3:h:unitronics:vision1210:-:*:*:*:*:*:*:*"
            ],
            "defaultStatus": "unaffected",
            "product": "vision1210",
            "vendor": "unitronics",
            "versions": [
              {
                "status": "affected",
                "version": "4.3, build 5"
              }
            ]
          }
        ],
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-2003",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-30T16:03:15.608159Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-30T16:04:09.807Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Vision1210",
          "vendor": "Unitronics",
          "versions": [
            {
              "status": "affected",
              "version": "4.3, build 5"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "user": "00000000-0000-4000-9000-000000000000",
          "value": "Carlos Antonini Cepeda"
        }
      ],
      "datePublic": "2023-07-06T10:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eEmbedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device\u0027s data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.\u003c/span\u003e\n\n"
            }
          ],
          "value": "Embedded malicious code vulnerability in Vision1210, in the build 5 of operating system version 4.3, which could allow a remote attacker to store base64-encoded malicious code in the device\u0027s data tables via the PCOM protocol, which can then be retrieved by a client and executed on the device.\n\n"
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-636",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-636: Hiding Malicious Data or Code within Files"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-506",
              "description": "CWE-506: Embedded Malicious Code",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-17T10:11:18.273Z",
        "orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
        "shortName": "INCIBE"
      },
      "references": [
        {
          "url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/embedded-malicious-code-vulnerability-unitronics-vision1210"
        },
        {
          "tags": [
            "related",
            "technical-description"
          ],
          "url": "https://www.hackplayers.com/2023/07/vulnerabilidad-vision1210-unitronics.html"
        }
      ],
      "source": {
        "advisory": "INCIBE-2023-0253",
        "discovery": "EXTERNAL"
      },
      "title": "Embedded malicious code vulnerability in Unitronics Vision1210",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
    "assignerShortName": "INCIBE",
    "cveId": "CVE-2023-2003",
    "datePublished": "2023-07-13T11:25:03.096Z",
    "dateReserved": "2023-04-12T14:08:51.192Z",
    "dateUpdated": "2024-10-30T16:04:09.807Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1"
}