CVE-2019-11997 (GCVE-0-2019-11997)
Vulnerability from cvelistv5 – Published: 2020-01-16 18:55 – Updated: 2024-08-04 23:10
VLAI?
Summary
A potential security vulnerability has been identified in HPE enhanced Internet Usage Manager (eIUM) versions 8.3 and 9.0. The vulnerability could be used for unauthorized access to information via cross site scripting. HPE has made the following software updates to resolve the vulnerability in eIUM. The eIUM 8.3 FP01 customers are advised to install eIUM83FP01Patch_QXCR1001711284.20190806-1244 patch. The eIUM 9.0 customers are advised to upgrade to eIUM 9.0 FP02 PI5 or later versions. For other versions, please, contact the product support.
Severity ?
No CVSS data available.
CWE
- remote cross-site scripting (xss)
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| HPE | HPE enhanced Internet Usage Manager (eIUM) |
Affected:
8.3
Affected: 9.0 |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T23:10:30.126Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn03975en_us"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "HPE enhanced Internet Usage Manager (eIUM)",
"vendor": "HPE",
"versions": [
{
"status": "affected",
"version": "8.3"
},
{
"status": "affected",
"version": "9.0"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A potential security vulnerability has been identified in HPE enhanced Internet Usage Manager (eIUM) versions 8.3 and 9.0. The vulnerability could be used for unauthorized access to information via cross site scripting. HPE has made the following software updates to resolve the vulnerability in eIUM. The eIUM 8.3 FP01 customers are advised to install eIUM83FP01Patch_QXCR1001711284.20190806-1244 patch. The eIUM 9.0 customers are advised to upgrade to eIUM 9.0 FP02 PI5 or later versions. For other versions, please, contact the product support."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "remote cross-site scripting (xss)",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2020-01-16T18:55:51.000Z",
"orgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"shortName": "hpe"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn03975en_us"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "security-alert@hpe.com",
"ID": "CVE-2019-11997",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "HPE enhanced Internet Usage Manager (eIUM)",
"version": {
"version_data": [
{
"version_value": "8.3"
},
{
"version_value": "9.0"
}
]
}
}
]
},
"vendor_name": "HPE"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A potential security vulnerability has been identified in HPE enhanced Internet Usage Manager (eIUM) versions 8.3 and 9.0. The vulnerability could be used for unauthorized access to information via cross site scripting. HPE has made the following software updates to resolve the vulnerability in eIUM. The eIUM 8.3 FP01 customers are advised to install eIUM83FP01Patch_QXCR1001711284.20190806-1244 patch. The eIUM 9.0 customers are advised to upgrade to eIUM 9.0 FP02 PI5 or later versions. For other versions, please, contact the product support."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "remote cross-site scripting (xss)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn03975en_us",
"refsource": "CONFIRM",
"url": "https://support.hpe.com/hpsc/doc/public/display?docLocale=en_US\u0026docId=emr_na-hpesbgn03975en_us"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "eb103674-0d28-4225-80f8-39fb86215de0",
"assignerShortName": "hpe",
"cveId": "CVE-2019-11997",
"datePublished": "2020-01-16T18:55:52.000Z",
"dateReserved": "2019-05-13T00:00:00.000Z",
"dateUpdated": "2024-08-04T23:10:30.126Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…