Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-27304 (GCVE-0-2020-27304)
Vulnerability from cvelistv5 – Published: 2021-10-21 15:42 – Updated: 2024-08-04 16:11| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| civetweb_project | civetweb |
Unaffected:
1.15 , < unspecified
(custom)
Affected: 1.8 , < unspecified (custom) |
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:11:36.691Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "civetweb",
"vendor": "civetweb_project",
"versions": [
{
"lessThan": "unspecified",
"status": "unaffected",
"version": "1.15",
"versionType": "custom"
},
{
"lessThan": "unspecified",
"status": "affected",
"version": "1.8",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-23",
"description": "CWE-23",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-06-14T10:06:41.000Z",
"orgId": "6b4ace4a-d6e0-415b-9ce8-aa20e97e4b24",
"shortName": "VDOO"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "vuln@vdoo.com",
"ID": "CVE-2020-27304",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "civetweb",
"version": {
"version_data": [
{
"version_affected": "!\u003e=",
"version_value": "1.15"
},
{
"version_affected": "\u003e=",
"version_value": "1.8"
}
]
}
}
]
},
"vendor_name": "civetweb_project"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-23"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/",
"refsource": "MISC",
"url": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/"
},
{
"name": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ",
"refsource": "MISC",
"url": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "6b4ace4a-d6e0-415b-9ce8-aa20e97e4b24",
"assignerShortName": "VDOO",
"cveId": "CVE-2020-27304",
"datePublished": "2021-10-21T15:42:23.000Z",
"dateReserved": "2020-10-19T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:11:36.691Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CERTFR-2022-AVI-547
Vulnerability from certfr_avis - Published: 2022-06-15 - Updated: 2022-06-15
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SICAM GridEdge Essential with GDS ARM (6MD7881-2AA10) versions antérieures à V2.6.6 | ||
| Siemens | N/A | SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) toutes versions | ||
| Siemens | N/A | SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) toutes versions | ||
| Siemens | N/A | TALON TC Compact (BACnet) versions antérieures à V3.5 | ||
| Siemens | N/A | SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) toutes versions | ||
| Siemens | N/A | SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) toutes versions | ||
| Siemens | N/A | SIMATIC RF650R (6GT2811-6AB20) versions antérieures à V4.0.1 | ||
| Siemens | N/A | SIMATIC RF610R (6GT2811-6BC10) versions antérieures à V4.0.1 | ||
| Siemens | N/A | SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | EN100 Ethernet module IEC 104 variant toutes versions | ||
| Siemens | N/A | SICAM GridEdge Essential ARM (6MD7881-2AA30) versions antérieures à V2.6.6 | ||
| Siemens | N/A | SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) toutes versions | ||
| Siemens | N/A | Teamcenter V12.4 versions antérieures à V12.4.0.13 | ||
| Siemens | N/A | SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE M804PB (6GK5804-0AP00-2AA2) toutes versions | ||
| Siemens | N/A | APOGEE PXC Modular (BACnet) versions antérieures à V3.5 | ||
| Siemens | N/A | SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) toutes versions | ||
| Siemens | N/A | EN100 Ethernet module IEC 61850 variant versions antérieures à V4.37 | ||
| Siemens | N/A | Xpedition Designer versions antérieures à X.2.11 | ||
| Siemens | N/A | SIMATIC NET PC Software V15 toutes versions | ||
| Siemens | N/A | SIMATIC RF186C (6GT2002-0JE20) versions antérieures à V2.0.1 | ||
| Siemens | N/A | SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) toutes versions | ||
| Siemens | N/A | SIMATIC CP 1543-1 (incl. SIPLUS variants) versions antérieures à V3.0 | ||
| Siemens | N/A | SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) toutes versions | ||
| Siemens | N/A | SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) toutes versions | ||
| Siemens | N/A | SIMATIC WinCC (TIA Portal) toutes versions | ||
| Siemens | N/A | EN100 Ethernet module Modbus TCP variant toutes versions | ||
| Siemens | N/A | SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) toutes versions | ||
| Siemens | N/A | SIMATIC RF188C (6GT2002-0JE40) versions antérieures à V2.0.1 | ||
| Siemens | N/A | SINAUT Software ST7sc toutes versions | ||
| Siemens | N/A | SIMATIC STEP 7 V5.X toutes versions | ||
| Siemens | N/A | SIMATIC RF166C (6GT2002-0EE20) versions antérieures à V2.0.1 | ||
| Siemens | N/A | Teamcenter V13.0 versions antérieures à V13.0.0.9 | ||
| Siemens | N/A | SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) toutes versions | ||
| Siemens | N/A | SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) toutes versions | ||
| Siemens | N/A | SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) toutes versions | ||
| Siemens | N/A | SIMATIC CP 343-1 Advanced (6GK7343-1GX31-0XE0) toutes versions | ||
| Siemens | N/A | SIMATIC CP 1626 (6GK1162-6AA01) toutes versions | ||
| Siemens | N/A | TIA Portal V15 toutes versions | ||
| Siemens | N/A | SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2) versions antérieures à V6.5 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) toutes versions | ||
| Siemens | N/A | RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) toutes versions | ||
| Siemens | N/A | SIMATIC NET PC Software V14 toutes versions | ||
| Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions | ||
| Siemens | N/A | RUGGEDCOM CROSSBOW Station Access Controller toutes versions | ||
| Siemens | N/A | SCALANCE XR528-6M (6GK5528-0AA00-2AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SIMATIC RF188CI (6GT2002-0JE60) versions antérieures à V2.0.1 | ||
| Siemens | N/A | SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) toutes versions | ||
| Siemens | N/A | SICAM GridEdge Essential Intel (6MD7881-2AA40) versions antérieures à V2.6.6 | ||
| Siemens | N/A | TIA Portal V16 toutes versions | ||
| Siemens | N/A | SIMATIC PDM toutes versions | ||
| Siemens | N/A | Spectrum Power 4 toutes versions using Shared HIS | ||
| Siemens | N/A | SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) toutes versions | ||
| Siemens | N/A | SCALANCE XR552-12M (6GK5552-0AA00-2AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SIMATIC NET PC Software V16 toutes versions | ||
| Siemens | N/A | SIMATIC CP 1545-1 (6GK7545-1GX00-0XE0) toutes versions | ||
| Siemens | N/A | SIMATIC MV540 H (6GF3540-0GE10) toutes versions | ||
| Siemens | N/A | SIMATIC RF360R (6GT2801-5BA30) versions antérieures à V2.0.1 | ||
| Siemens | N/A | SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) toutes versions | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) toutes versions | ||
| Siemens | N/A | SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE XM408-4C (6GK5408-4GP00-2AM2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2) versions antérieures à V6.5 | ||
| Siemens | N/A | SINUMERIK Edge versions antérieures à V3.3.0 | ||
| Siemens | N/A | SCALANCE LPE9403 (6GK5998-3GS00-2AC2) versions antérieures à V2.0 | ||
| Siemens | N/A | Spectrum Power MGMS toutes versions using Shared HIS | ||
| Siemens | N/A | SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) toutes versions | ||
| Siemens | N/A | Teamcenter V13.2 toutes versions | ||
| Siemens | N/A | SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) toutes versions | ||
| Siemens | N/A | RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) toutes versions | ||
| Siemens | N/A | SIMATIC CP 1545-1 (6GK7545-1GX00-0XE0) versions antérieures à V1.1 | ||
| Siemens | N/A | SCALANCE S615 (6GK5615-0AA00-2AA2) toutes versions | ||
| Siemens | N/A | SCALANCE M874-3 (6GK5874-3AA00-2AA2) toutes versions | ||
| Siemens | N/A | RUGGEDCOM ROX Series toutes versions | ||
| Siemens | N/A | SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) toutes versions | ||
| Siemens | N/A | SIMATIC RF185C (6GT2002-0JE10) versions antérieures à V2.0.1 | ||
| Siemens | N/A | SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE MUM853-1 (RoW) (6GK5853-2EA00-2AA1) toutes versions | ||
| Siemens | N/A | EN100 Ethernet module PROFINET IO variant toutes versions | ||
| Siemens | N/A | SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | TIA Portal Cloud toutes versions | ||
| Siemens | N/A | SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) toutes versions | ||
| Siemens | N/A | SIMATIC S7-PLCSIM Advanced toutes versions | ||
| Siemens | N/A | SINEMA Remote Connect Server versions antérieures à V3.1 | ||
| Siemens | N/A | SIMATIC Logon toutes versions | ||
| Siemens | N/A | SCALANCE M874-2 (6GK5874-2AA00-2AA2) toutes versions | ||
| Siemens | N/A | SIMATIC MV550 S (6GF3550-0CD10) toutes versions | ||
| Siemens | N/A | SIMATIC MV550 H (6GF3550-0GE10) toutes versions | ||
| Siemens | N/A | TIM 1531 IRC (6GK7543-1MX00-0XE0) toutes versions | ||
| Siemens | N/A | SIPLUS NET CP 343-1 Advanced (6AG1343-1GX31-4XE0) toutes versions | ||
| Siemens | N/A | Mendix SAML Module (Mendix 8 compatible) versions antérieures à 2.2.2 | ||
| Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions | ||
| Siemens | N/A | Teamcenter V13.3 versions antérieures à V13.3.0.3 | ||
| Siemens | N/A | SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2) versions antérieures à V6.5 | ||
| Siemens | N/A | Teamcenter Active Workspace V6.0 versions antérieures à V6.0.3 | ||
| Siemens | N/A | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) toutes versions | ||
| Siemens | N/A | SCALANCE SC622-2C (6GK5622-2GS00-2AC2) toutes versions versions antérieures à V2.3.1 | ||
| Siemens | N/A | Mendix SAML Module (Mendix 7 compatible) versions antérieures à 1.16.6 | ||
| Siemens | N/A | EN100 Ethernet module DNP3 IP variant toutes versions | ||
| Siemens | N/A | SCALANCE XM416-4C (6GK5416-4GS00-2AM2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) toutes versions | ||
| Siemens | N/A | Industrial Edge - PROFINET IO Connector toutes versions | ||
| Siemens | N/A | SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2) versions antérieures à V6.5 | ||
| Siemens | N/A | SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) toutes versions | ||
| Siemens | N/A | RUGGEDCOM ROS Series toutes versions | ||
| Siemens | N/A | TIA Portal V17 toutes versions | ||
| Siemens | N/A | TALON TC Modular (BACnet) versions antérieures à V3.5 | ||
| Siemens | N/A | SIMATIC PCS 7 TeleControl toutes versions | ||
| Siemens | N/A | APOGEE PXC Compact (BACnet) versions antérieures à V3.5 | ||
| Siemens | N/A | SCALANCE MUM856-1 (NAM) (6GK5856-2EA00-3BA1) toutes versions | ||
| Siemens | N/A | SIMATIC RF685R (6GT2811-6CA10) versions antérieures à V4.0.1 | ||
| Siemens | N/A | SINEMA Server V14 toutes versions | ||
| Siemens | N/A | SCALANCE SC646-2C (6GK5646-2GS00-2AC2) toutes versions versions antérieures à V2.3.1 | ||
| Siemens | N/A | SIMATIC RF680R (6GT2811-6AA10) versions antérieures à V4.0.1 | ||
| Siemens | N/A | SIMATIC MV560 U (6GF3560-0LE10) toutes versions | ||
| Siemens | N/A | Industrial Edge - SIMATIC S7 Connector App versions antérieures à V1.7.0 | ||
| Siemens | N/A | SINEC INS toutes versions | ||
| Siemens | N/A | SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) toutes versions | ||
| Siemens | N/A | SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE SC636-2C (6GK5636-2GS00-2AC2) toutes versions versions antérieures à V2.3.1 | ||
| Siemens | N/A | TIA Administrator toutes versions | ||
| Siemens | N/A | SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | TeleControl Server Basic V3 toutes versions | ||
| Siemens | N/A | SINAUT ST7CC toutes versions | ||
| Siemens | N/A | SCALANCE XM408-8C (6GK5408-8GS00-2AM2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SIMATIC NET PC Software V17 toutes versions | ||
| Siemens | N/A | Spectrum Power 7 toutes versions using Shared HIS | ||
| Siemens | N/A | SIMATIC MV560 X (6GF3560-0HE10) toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller (incl. F) toutes versions | ||
| Siemens | N/A | SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) toutes versions | ||
| Siemens | N/A | SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) toutes versions | ||
| Siemens | N/A | SINEMA Remote Connect Server versions antérieures à 3.0 SP2 | ||
| Siemens | N/A | Industrial Edge - OPC UA Connector toutes versions | ||
| Siemens | N/A | Teamcenter Active Workspace V5.2 versions antérieures à V5.2.9 | ||
| Siemens | N/A | SCALANCE SC642-2C (6GK5642-2GS00-2AC2) toutes versions versions antérieures à V2.3.1 | ||
| Siemens | N/A | SINEC NMS toutes versions | ||
| Siemens | N/A | Mendix SAML Module (Mendix 9 compatible) versions antérieures à 3.2.3 | ||
| Siemens | N/A | Teamcenter V14.0 toutes versions | ||
| Siemens | N/A | SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) toutes versions | ||
| Siemens | N/A | SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) toutes versions | ||
| Siemens | N/A | SIMATIC RF615R (6GT2811-6CC10) versions antérieures à V4.0.1 | ||
| Siemens | N/A | SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) toutes versions | ||
| Siemens | N/A | SIMATIC RF186CI (6GT2002-0JE50) versions antérieures à V2.0.1 | ||
| Siemens | N/A | SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2) versions antérieures à V6.5 | ||
| Siemens | N/A | SIMATIC CP 1628 (6GK1162-8AA00) toutes versions | ||
| Siemens | N/A | SICAM GridEdge Essential with GDS Intel (6MD7881-2AA20) versions antérieures à V2.6.6 | ||
| Siemens | N/A | Teamcenter V13.1 versions antérieures à V13.1.0.9 | ||
| Siemens | N/A | SCALANCE SC632-2C (6GK5632-2GS00-2AC2) toutes versions versions antérieures à V2.3.1 | ||
| Siemens | N/A | SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) toutes versions | ||
| Siemens | N/A | SIMATIC MV540 S (6GF3540-0CD10) toutes versions | ||
| Siemens | N/A | SIMATIC CP 443-1 OPC UA (6GK7443-1UX00-0XE0) toutes versions | ||
| Siemens | N/A | SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) toutes versions | ||
| Siemens | N/A | SIMATIC PCS neo toutes versions | ||
| Siemens | N/A | RUGGEDCOM NMS toutes versions |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SCALANCE XR526-8C, 2x230V (6GK5526-8GS00-4AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM GridEdge Essential with GDS ARM (6MD7881-2AA10) versions ant\u00e9rieures \u00e0 V2.6.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M876-3 (EVDO) (6GK5876-3AA02-2BA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-1 (6GK7243-1BX30-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TALON TC Compact (BACnet) versions ant\u00e9rieures \u00e0 V3.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET CP 443-1 Advanced (6AG1443-1GX30-4XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M876-4 (NAM) (6GK5876-4AA00-2DA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF650R (6GT2811-6AB20) versions ant\u00e9rieures \u00e0 V4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF610R (6GT2811-6BC10) versions ant\u00e9rieures \u00e0 V4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR526-8C, 1x230V (L3 int.) (6GK5526-8GR00-3AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module IEC 104 variant toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM GridEdge Essential ARM (6MD7881-2AA30) versions ant\u00e9rieures \u00e0 V2.6.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET CP 1242-7 V2 (6AG1242-7KX31-7XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V12.4 versions ant\u00e9rieures \u00e0 V12.4.0.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR524-8C, 1x230V (L3 int.) (6GK5524-8GR00-3AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR524-8C, 2x230V (L3 int.) (6GK5524-8GR00-4AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M804PB (6GK5804-0AP00-2AA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (BACnet) versions ant\u00e9rieures \u00e0 V3.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 443-1 Advanced (6GK7443-1GX30-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module IEC 61850 variant versions ant\u00e9rieures \u00e0 V4.37",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Xpedition Designer versions ant\u00e9rieures \u00e0 X.2.11",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC Software V15 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF186C (6GT2002-0JE20) versions ant\u00e9rieures \u00e0 V2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M816-1 ADSL-Router (Annex A) (6GK5816-1AA00-2AA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1543-1 (incl. SIPLUS variants) versions ant\u00e9rieures \u00e0 V3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M876-3 (ROK) (6GK5876-3AA02-2EA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR552-12M (2HR2) (6GK5552-0AA00-2HR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M812-1 ADSL-Router (Annex A) (6GK5812-1AA00-2AA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC (TIA Portal) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module Modbus TCP variant toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE MUM856-1 (RoW) (6GK5856-2EA00-3AA1) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF188C (6GT2002-0JE40) versions ant\u00e9rieures \u00e0 V2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAUT Software ST7sc toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 V5.X toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF166C (6GT2002-0EE20) versions ant\u00e9rieures \u00e0 V2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.0 versions ant\u00e9rieures \u00e0 V13.0.0.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M812-1 ADSL-Router (Annex B) (6GK5812-1BA00-2AA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS TIM 1531 IRC (6AG1543-1MX00-7XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1543-1 (6GK7543-1AX00-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 343-1 Advanced (6GK7343-1GX31-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1626 (6GK1162-6AA01) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Portal V15 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM408-8C (L3 int.) (6GK5408-8GR00-2AM2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 CC716 (6GK1411-5AC00) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224 LTE(4G) EU (6GK6108-4AM00-2BA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC Software V14 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM CROSSBOW Station Access Controller toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR528-6M (6GK5528-0AA00-2AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF188CI (6GT2002-0JE60) versions ant\u00e9rieures \u00e0 V2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1200 CP 1243-1 RAIL (6AG2243-1BX30-1XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM GridEdge Essential Intel (6MD7881-2AA40) versions ant\u00e9rieures \u00e0 V2.6.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Portal V16 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PDM toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Spectrum Power 4 toutes versions using Shared HIS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET CP 1543-1 (6AG1543-1AX00-2XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR552-12M (6GK5552-0AA00-2AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC Software V16 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1545-1 (6GK7545-1GX00-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV540 H (6GF3540-0GE10) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF360R (6GT2801-5BA30) versions ant\u00e9rieures \u00e0 V2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE MUM856-1 (EU) (6GK5856-2EA00-3DA1) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR526-8C, 2x230V (L3 int.) (6GK5526-8GR00-4AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR526-8C, 1x230V (6GK5526-8GS00-3AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM408-4C (6GK5408-4GP00-2AM2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM408-4C (L3 int.) (6GK5408-4GQ00-2AM2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Edge versions ant\u00e9rieures \u00e0 V3.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE LPE9403 (6GK5998-3GS00-2AC2) versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Spectrum Power MGMS toutes versions using Shared HIS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR526-8C, 24V (L3 int.) (6GK5526-8GR00-2AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200SP Open Controller (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M826-2 SHDSL-Router (6GK5826-2AB00-2AB2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.2 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1242-7 V2 (6GK7242-7KX31-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224 LTE(4G) NAM (6GK6108-4AM00-2DA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1545-1 (6GK7545-1GX00-0XE0) versions ant\u00e9rieures \u00e0 V1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE S615 (6GK5615-0AA00-2AA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M874-3 (6GK5874-3AA00-2AA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROX Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1542SP-1 (6GK7542-6UX00-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF185C (6GT2002-0JE10) versions ant\u00e9rieures \u00e0 V2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR528-6M (2HR2, L3 int.) (6GK5528-0AR00-2HR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE MUM853-1 (RoW) (6GK5853-2EA00-2AA1) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module PROFINET IO variant toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR524-8C, 24V (6GK5524-8GS00-2AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Portal Cloud toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1543SP-1 (6GK7543-6WX00-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Remote Connect Server versions ant\u00e9rieures \u00e0 V3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Logon toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M874-2 (6GK5874-2AA00-2AA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV550 S (6GF3550-0CD10) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV550 H (6GF3550-0GE10) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 1531 IRC (6GK7543-1MX00-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET CP 343-1 Advanced (6AG1343-1GX31-4XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix SAML Module (Mendix 8 compatible) versions ant\u00e9rieures \u00e0 2.2.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.3 versions ant\u00e9rieures \u00e0 V13.3.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR552-12M (2HR2) (6GK5552-0AR00-2HR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace V6.0 versions ant\u00e9rieures \u00e0 V6.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M876-4 (EU) (6GK5876-4AA00-2BA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC622-2C (6GK5622-2GS00-2AC2) toutes versions versions ant\u00e9rieures \u00e0 V2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix SAML Module (Mendix 7 compatible) versions ant\u00e9rieures \u00e0 1.16.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "EN100 Ethernet module DNP3 IP variant toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM416-4C (6GK5416-4GS00-2AM2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE M816-1 ADSL-Router (Annex B) (6GK5816-1BA00-2AA2) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Industrial Edge - PROFINET IO Connector toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM416-4C (L3 int.) (6GK5416-4GR00-2AM2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CP 1543SP-1 ISEC TX RAIL (6AG2543-6WX00-4XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS Series toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Portal V17 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TALON TC Modular (BACnet) versions ant\u00e9rieures \u00e0 V3.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 TeleControl toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (BACnet) versions ant\u00e9rieures \u00e0 V3.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE MUM856-1 (NAM) (6GK5856-2EA00-3BA1) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF685R (6GT2811-6CA10) versions ant\u00e9rieures \u00e0 V4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Server V14 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC646-2C (6GK5646-2GS00-2AC2) toutes versions versions ant\u00e9rieures \u00e0 V2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF680R (6GT2811-6AA10) versions ant\u00e9rieures \u00e0 V4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV560 U (6GF3560-0LE10) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Industrial Edge - SIMATIC S7 Connector App versions ant\u00e9rieures \u00e0 V1.7.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC INS toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR524-8C, 24V (L3 int.) (6GK5524-8GR00-2AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR524-8C, 2x230V (6GK5524-8GS00-4AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC636-2C (6GK5636-2GS00-2AC2) toutes versions versions ant\u00e9rieures \u00e0 V2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Administrator toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR526-8C, 24V (6GK5526-8GS00-2AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TeleControl Server Basic V3 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAUT ST7CC toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM408-8C (6GK5408-8GS00-2AM2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR552-12M (2HR2, L3 int.) (6GK5552-0AR00-2AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR528-6M (2HR2) (6GK5528-0AA00-2HR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC Software V17 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Spectrum Power 7 toutes versions using Shared HIS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV560 X (6GF3560-0HE10) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller (incl. F) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-7 LTE EU (6GK7243-7KX30-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-7 LTE US (6GK7243-7SX30-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Remote Connect Server versions ant\u00e9rieures \u00e0 3.0 SP2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Industrial Edge - OPC UA Connector toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace V5.2 versions ant\u00e9rieures \u00e0 V5.2.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC642-2C (6GK5642-2GS00-2AC2) toutes versions versions ant\u00e9rieures \u00e0 V2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC NMS toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix SAML Module (Mendix 9 compatible) versions ant\u00e9rieures \u00e0 3.2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V14.0 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200SP CP 1543SP-1 ISEC (6AG1543-6WX00-7XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-1200 CP 1243-1 (6AG1243-1BX30-2AX0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF615R (6GT2811-6CC10) versions ant\u00e9rieures \u00e0 V4.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Cloud Connect 7 CC712 (6GK1411-1AC00) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RF186CI (6GT2002-0JE50) versions ant\u00e9rieures \u00e0 V2.0.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR528-6M (L3 int.) (6GK5528-0AR00-2AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR524-8C, 1x230V (6GK5524-8GS00-3AR2) versions ant\u00e9rieures \u00e0 V6.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1628 (6GK1162-8AA00) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM GridEdge Essential with GDS Intel (6MD7881-2AA20) versions ant\u00e9rieures \u00e0 V2.6.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter V13.1 versions ant\u00e9rieures \u00e0 V13.1.0.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC632-2C (6GK5632-2GS00-2AC2) toutes versions versions ant\u00e9rieures \u00e0 V2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 1243-8 IRC (6GK7243-8RX30-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV540 S (6GF3540-0CD10) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CP 443-1 OPC UA (6GK7443-1UX00-0XE0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE MUM853-1 (EU) (6GK5853-2EA00-2DA1) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS neo toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM NMS toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-32285",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32285"
},
{
"name": "CVE-2022-32286",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32286"
},
{
"name": "CVE-2021-45960",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-45960"
},
{
"name": "CVE-2021-20317",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-20317"
},
{
"name": "CVE-2022-32258",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32258"
},
{
"name": "CVE-2021-41091",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41091"
},
{
"name": "CVE-2021-22925",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22925"
},
{
"name": "CVE-2022-30231",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30231"
},
{
"name": "CVE-2021-33196",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33196"
},
{
"name": "CVE-2022-32254",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32254"
},
{
"name": "CVE-2022-22823",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22823"
},
{
"name": "CVE-2022-32145",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32145"
},
{
"name": "CVE-2022-32259",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32259"
},
{
"name": "CVE-2022-32262",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32262"
},
{
"name": "CVE-2017-9947",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-9947"
},
{
"name": "CVE-2022-32255",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32255"
},
{
"name": "CVE-2020-27304",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27304"
},
{
"name": "CVE-2022-25315",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25315"
},
{
"name": "CVE-2022-22822",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22822"
},
{
"name": "CVE-2022-32252",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32252"
},
{
"name": "CVE-2021-22924",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22924"
},
{
"name": "CVE-2022-25313",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25313"
},
{
"name": "CVE-2021-39275",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-39275"
},
{
"name": "CVE-2021-37182",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37182"
},
{
"name": "CVE-2020-9272",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9272"
},
{
"name": "CVE-2021-39293",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-39293"
},
{
"name": "CVE-2021-33910",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33910"
},
{
"name": "CVE-2022-23852",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23852"
},
{
"name": "CVE-2022-22825",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22825"
},
{
"name": "CVE-2022-25314",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25314"
},
{
"name": "CVE-2022-23990",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23990"
},
{
"name": "CVE-2022-26476",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26476"
},
{
"name": "CVE-2022-25235",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25235"
},
{
"name": "CVE-2022-0847",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0847"
},
{
"name": "CVE-2022-30228",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30228"
},
{
"name": "CVE-2021-46143",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-46143"
},
{
"name": "CVE-2021-41092",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41092"
},
{
"name": "CVE-2022-32251",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32251"
},
{
"name": "CVE-2021-34798",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-34798"
},
{
"name": "CVE-2021-36221",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-36221"
},
{
"name": "CVE-2021-41089",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41089"
},
{
"name": "CVE-2022-30230",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30230"
},
{
"name": "CVE-2020-9273",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9273"
},
{
"name": "CVE-2022-30229",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30229"
},
{
"name": "CVE-2022-22827",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22827"
},
{
"name": "CVE-2022-29034",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-29034"
},
{
"name": "CVE-2022-30937",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30937"
},
{
"name": "CVE-2022-25236",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25236"
},
{
"name": "CVE-2022-0778",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0778"
},
{
"name": "CVE-2022-27219",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27219"
},
{
"name": "CVE-2022-27221",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27221"
},
{
"name": "CVE-2022-22826",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22826"
},
{
"name": "CVE-2022-31619",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31619"
},
{
"name": "CVE-2022-32261",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32261"
},
{
"name": "CVE-2022-32260",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32260"
},
{
"name": "CVE-2021-40438",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40438"
},
{
"name": "CVE-2021-4034",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-4034"
},
{
"name": "CVE-2022-22824",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-22824"
},
{
"name": "CVE-2022-27220",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27220"
},
{
"name": "CVE-2022-31465",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31465"
},
{
"name": "CVE-2017-9946",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-9946"
},
{
"name": "CVE-2021-41103",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41103"
},
{
"name": "CVE-2022-32253",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32253"
},
{
"name": "CVE-2022-32256",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32256"
},
{
"name": "CVE-2021-37209",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37209"
}
],
"initial_release_date": "2022-06-15T00:00:00",
"last_revision_date": "2022-06-15T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-547",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-06-15T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-148078 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-148078.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-220589 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-220589.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-988345 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-988345.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-484086 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-484086.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-330556 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-330556.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-145224 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-145224.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-685781 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-685781.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-693555 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-693555.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-911567 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-911567.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-401167 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-401167.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-764417 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764417.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-712929 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-712929.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-679335 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-679335.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-388239 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-388239.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-631336 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-631336.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-740594 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-740594.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-222547 du 14 juin 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-222547.html"
}
]
}
CERTFR-2022-AVI-216
Vulnerability from certfr_avis - Published: 2022-03-08 - Updated: 2022-03-08
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
- Mendix Forgot Password Appstore module versions 3.2.x antérieures à 3.2.2
- Mendix Forgot Password Appstore module versions 3.3.x à 3.5.x antérieures à 3.5.1
- Mendix Applications utilisant Mendix versions 7.x antérieures à 7.23.29
- Mendix Applications utilisant Mendix versions 8.x antérieures à 8.18.16
- COMOS versions antérieures à 10.4.1
- Simcenter STAR-CCM+ Viewer versions antérieures à V2022.1
- SIMOTICS CONNECT 400 versions antérieures à 1.0.0.0
- Climatix POL909 (module AWB) versions antérieures à 11.44
- Climatix POL909 (module AWM) versions antérieures à 11.36
- RUGGEDCOM ROS M2100, RMC8388, RS416v2, RS900G, RS900G (32M), RSG900, RSG920P, RSG2100 (32M), RSG2100P, RSG2100P (32M), RSG2288, RSG2300, RSG2300P, RSG2488, RSL910, RST916C, RST916P et RST2228 versions antérieures à 5.6.0
- SINUMERIK MC versions antérieures à 1.15 SP1
- SINUMERIK ONE versions antérieures à 6.15 SP1
- SINEC INS versions antérieures à 1.0.1.1
- RUGGEDCOM ROX MX5000, RX1400, RX1500, RX1501, RX1510, RX1511, RX1512, RX1524, RX1536 et RX5000 versions antérieures à 2.15.0
- Polarion Subversion Webclient versions antérieures à 21 R2 P2
- RUGGEDCOM ROS i800, i801, i802, i803, M969, M2100, M2200, RMC, RMC20, RMC30, RMC40, RMC41, RMC8388, RP110, RS400, RS401, RS416, RS416v2, RS900 (32M), RS900G, RS900G (32M), RS900GP, RS900L, RS900L, RS900W, RS910, RS910L, RS910W, RS920L, RS920W, RS930L, RS930W, RS940G, RS969, RS8000, RS8000A, RS8000H, RS8000T, RSG900, RSG900C, RSG900G, RSG900R, RSG907R, RSG908C, RSG909R, RSG910C, RSG920P, RSG2100, RSG2100 (32M), RSG2100P, RSG2100P (32M), RSG2200, RSG2288, RSG2300, RSG2300P, RSG2488, RSL910, RST916C, RST916P et RST2228 versions antérieures à 5.6.0
L'éditeur ne propose pas de correctif pour :
- Mendix Applications utilisant Mendix versions 9
- SINEC NMS toutes versions
Se référer aux mesures de contournement proposées dans la section Documentation.
| Vendor | Product | Description |
|---|
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [],
"affected_systems_content": "\u003cul\u003e \u003cli\u003eMendix Forgot Password Appstore module versions 3.2.x ant\u00e9rieures \u00e0 3.2.2\u003c/li\u003e \u003cli\u003eMendix Forgot Password Appstore module versions 3.3.x \u00e0 3.5.x ant\u00e9rieures \u00e0 3.5.1\u003c/li\u003e \u003cli\u003eMendix Applications utilisant Mendix versions 7.x ant\u00e9rieures \u00e0 7.23.29\u003c/li\u003e \u003cli\u003eMendix Applications utilisant Mendix versions 8.x ant\u00e9rieures \u00e0 8.18.16\u003c/li\u003e \u003cli\u003eCOMOS versions ant\u00e9rieures \u00e0 10.4.1\u003c/li\u003e \u003cli\u003eSimcenter STAR-CCM+ Viewer versions ant\u00e9rieures \u00e0 V2022.1\u003c/li\u003e \u003cli\u003eSIMOTICS CONNECT 400 versions ant\u00e9rieures \u00e0 1.0.0.0\u003c/li\u003e \u003cli\u003eClimatix POL909 (module AWB) versions ant\u00e9rieures \u00e0 11.44\u003c/li\u003e \u003cli\u003eClimatix POL909 (module AWM) versions ant\u00e9rieures \u00e0 11.36\u003c/li\u003e \u003cli\u003eRUGGEDCOM ROS M2100, RMC8388, RS416v2, RS900G, RS900G (32M), RSG900, RSG920P, RSG2100 (32M), RSG2100P, RSG2100P (32M), RSG2288, RSG2300, RSG2300P, RSG2488, RSL910, RST916C, RST916P et RST2228 versions ant\u00e9rieures \u00e0 5.6.0\u003c/li\u003e \u003cli\u003eSINUMERIK MC versions ant\u00e9rieures \u00e0 1.15 SP1\u003c/li\u003e \u003cli\u003eSINUMERIK ONE versions ant\u00e9rieures \u00e0 6.15 SP1\u003c/li\u003e \u003cli\u003eSINEC INS versions ant\u00e9rieures \u00e0 1.0.1.1\u003c/li\u003e \u003cli\u003eRUGGEDCOM ROX MX5000, RX1400, RX1500, RX1501, RX1510, RX1511, RX1512, RX1524, RX1536 et RX5000 versions ant\u00e9rieures \u00e0 2.15.0\u003c/li\u003e \u003cli\u003ePolarion Subversion Webclient versions ant\u00e9rieures \u00e0 21 R2 P2\u003c/li\u003e \u003cli\u003eRUGGEDCOM ROS i800, i801, i802, i803, M969, M2100, M2200, RMC, RMC20, RMC30, RMC40, RMC41, RMC8388, RP110, RS400, RS401, RS416, RS416v2, RS900 (32M), RS900G, RS900G (32M), RS900GP, RS900L, RS900L, RS900W, RS910, RS910L, RS910W, RS920L, RS920W, RS930L, RS930W, RS940G, RS969, RS8000, RS8000A, RS8000H, RS8000T, RSG900, RSG900C, RSG900G, RSG900R, RSG907R, RSG908C, RSG909R, RSG910C, RSG920P, RSG2100, RSG2100 (32M), RSG2100P, RSG2100P (32M), RSG2200, RSG2288, RSG2300, RSG2300P, RSG2488, RSL910, RST916C, RST916P et RST2228 versions ant\u00e9rieures \u00e0 5.6.0\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eL\u0027\u00e9diteur ne propose pas de correctif pour :\u003c/p\u003e \u003cul\u003e \u003cli\u003eMendix Applications utilisant Mendix versions 9\u003c/li\u003e \u003cli\u003eSINEC NMS toutes versions\u003c/li\u003e \u003c/ul\u003e \u003cp\u003eSe r\u00e9f\u00e9rer aux mesures de contournement propos\u00e9es dans la section Documentation.\u003c/p\u003e \u003cp\u003e\u0026nbsp;\u003c/p\u003e ",
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-44478",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44478"
},
{
"name": "CVE-2021-22898",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22898"
},
{
"name": "CVE-2020-13871",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13871"
},
{
"name": "CVE-2021-42017",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42017"
},
{
"name": "CVE-2022-24282",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24282"
},
{
"name": "CVE-2021-25215",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25215"
},
{
"name": "CVE-2019-19317",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19317"
},
{
"name": "CVE-2020-8169",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8169"
},
{
"name": "CVE-2021-25174",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25174"
},
{
"name": "CVE-2021-22925",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22925"
},
{
"name": "CVE-2021-37701",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37701"
},
{
"name": "CVE-2021-32944",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32944"
},
{
"name": "CVE-2019-19244",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19244"
},
{
"name": "CVE-2021-27290",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27290"
},
{
"name": "CVE-2021-42020",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42020"
},
{
"name": "CVE-2020-8285",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8285"
},
{
"name": "CVE-2021-22901",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22901"
},
{
"name": "CVE-2021-22940",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22940"
},
{
"name": "CVE-2021-32804",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32804"
},
{
"name": "CVE-2020-13632",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13632"
},
{
"name": "CVE-2022-24281",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24281"
},
{
"name": "CVE-2021-32936",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32936"
},
{
"name": "CVE-2021-22930",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22930"
},
{
"name": "CVE-2019-19926",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19926"
},
{
"name": "CVE-2020-9327",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-9327"
},
{
"name": "CVE-2020-8286",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8286"
},
{
"name": "CVE-2020-7774",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7774"
},
{
"name": "CVE-2021-22918",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22918"
},
{
"name": "CVE-2020-27304",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27304"
},
{
"name": "CVE-2021-32946",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32946"
},
{
"name": "CVE-2021-41543",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41543"
},
{
"name": "CVE-2020-8177",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8177"
},
{
"name": "CVE-2020-1971",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-1971"
},
{
"name": "CVE-2020-13630",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13630"
},
{
"name": "CVE-2021-3450",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3450"
},
{
"name": "CVE-2021-22939",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22939"
},
{
"name": "CVE-2019-19646",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19646"
},
{
"name": "CVE-2021-40366",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40366"
},
{
"name": "CVE-2021-41542",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41542"
},
{
"name": "CVE-2021-41541",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41541"
},
{
"name": "CVE-2021-22924",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22924"
},
{
"name": "CVE-2022-24309",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24309"
},
{
"name": "CVE-2020-8265",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8265"
},
{
"name": "CVE-2021-37713",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37713"
},
{
"name": "CVE-2021-22947",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22947"
},
{
"name": "CVE-2019-19925",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19925"
},
{
"name": "CVE-2021-22922",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22922"
},
{
"name": "CVE-2019-19924",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19924"
},
{
"name": "CVE-2021-32938",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32938"
},
{
"name": "CVE-2020-11656",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11656"
},
{
"name": "CVE-2022-26317",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26317"
},
{
"name": "CVE-2021-22946",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22946"
},
{
"name": "CVE-2021-37712",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37712"
},
{
"name": "CVE-2020-8284",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8284"
},
{
"name": "CVE-2021-32940",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32940"
},
{
"name": "CVE-2021-3711",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3711"
},
{
"name": "CVE-2021-37208",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37208"
},
{
"name": "CVE-2021-32948",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32948"
},
{
"name": "CVE-2021-3449",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3449"
},
{
"name": "CVE-2022-26313",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26313"
},
{
"name": "CVE-2021-22921",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22921"
},
{
"name": "CVE-2021-25216",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25216"
},
{
"name": "CVE-2020-15358",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-15358"
},
{
"name": "CVE-2021-43527",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-43527"
},
{
"name": "CVE-2019-19242",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19242"
},
{
"name": "CVE-2021-22897",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22897"
},
{
"name": "CVE-2021-32803",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32803"
},
{
"name": "CVE-2021-25177",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25177"
},
{
"name": "CVE-2021-25175",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25175"
},
{
"name": "CVE-2021-22884",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22884"
},
{
"name": "CVE-2021-32952",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32952"
},
{
"name": "CVE-2019-19880",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19880"
},
{
"name": "CVE-2018-7160",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7160"
},
{
"name": "CVE-2021-32950",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32950"
},
{
"name": "CVE-2021-3672",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3672"
},
{
"name": "CVE-2021-31346",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31346"
},
{
"name": "CVE-2022-26314",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26314"
},
{
"name": "CVE-2021-31784",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31784"
},
{
"name": "CVE-2021-22883",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22883"
},
{
"name": "CVE-2020-8231",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8231"
},
{
"name": "CVE-2020-13631",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13631"
},
{
"name": "CVE-2021-25214",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25214"
},
{
"name": "CVE-2021-22931",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22931"
},
{
"name": "CVE-2021-31889",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31889"
},
{
"name": "CVE-2022-24408",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24408"
},
{
"name": "CVE-2021-42016",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42016"
},
{
"name": "CVE-2021-3712",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3712"
},
{
"name": "CVE-2021-39134",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-39134"
},
{
"name": "CVE-2019-19645",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19645"
},
{
"name": "CVE-2020-11655",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11655"
},
{
"name": "CVE-2020-8287",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8287"
},
{
"name": "CVE-2021-22926",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22926"
},
{
"name": "CVE-2022-24661",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24661"
},
{
"name": "CVE-2021-22890",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22890"
},
{
"name": "CVE-2021-25219",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25219"
},
{
"name": "CVE-2021-23840",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23840"
},
{
"name": "CVE-2021-42018",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42018"
},
{
"name": "CVE-2021-22923",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22923"
},
{
"name": "CVE-2019-19923",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19923"
},
{
"name": "CVE-2021-39135",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-39135"
},
{
"name": "CVE-2021-25176",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25176"
},
{
"name": "CVE-2021-31890",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31890"
},
{
"name": "CVE-2021-25178",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25178"
},
{
"name": "CVE-2021-22876",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22876"
},
{
"name": "CVE-2021-23362",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-23362"
},
{
"name": "CVE-2019-19603",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19603"
},
{
"name": "CVE-2021-25217",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25217"
},
{
"name": "CVE-2021-25173",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25173"
},
{
"name": "CVE-2021-22945",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22945"
},
{
"name": "CVE-2022-25311",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25311"
},
{
"name": "CVE-2021-31344",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31344"
},
{
"name": "CVE-2021-37209",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37209"
},
{
"name": "CVE-2021-42019",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42019"
},
{
"name": "CVE-2020-8625",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-8625"
}
],
"initial_release_date": "2022-03-08T00:00:00",
"last_revision_date": "2022-03-08T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-216",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-03-08T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
},
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-166747 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-166747.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-252466 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-252466.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-562051 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-562051.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-223353 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-223353.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-337210 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-337210.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-148641 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-148641.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-389290 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-389290.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-764417 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-764417.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-256353 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-256353.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-703715 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-703715.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-594438 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-594438.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-415938 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-415938.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-134279 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-134279.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-155599 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-155599.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-406691 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-406691.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-250085 du 8 mars 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-250085.html"
}
]
}
CVE-2020-27304
Vulnerability from fstec - Published: 19.10.2021{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:C/I:C/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Siemens AG, \u0421\u043e\u043e\u0431\u0449\u0435\u0441\u0442\u0432\u043e \u0441\u0432\u043e\u0431\u043e\u0434\u043d\u043e\u0433\u043e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 1.0.1.1 (SINEC INS), \u0434\u043e 2.0 (SCALANCE LPE9403), \u043e\u0442 1.8 \u0434\u043e 1.15 (CivetWeb)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "19.10.2021",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "13.09.2024",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "22.07.2022",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2022-04587",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2020-27304",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "SINEC INS, SCALANCE LPE9403, CivetWeb",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430 \u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0444\u0430\u0439\u043b\u043e\u0432 \u0432\u0435\u0431-\u0441\u0435\u0440\u0432\u0435\u0440\u0430 CivetWeb, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043e\u0448\u0438\u0431\u043a\u0430\u043c\u0438 \u0432 \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0435 \u043e\u0442\u043d\u043e\u0441\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0443\u0442\u0438 \u043a \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u0443, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0421\u0443\u0449\u0435\u0441\u0442\u0432\u0443\u0435\u0442 \u0432 \u043e\u0442\u043a\u0440\u044b\u0442\u043e\u043c \u0434\u043e\u0441\u0442\u0443\u043f\u0435",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u0432\u0435\u0440\u043d\u043e\u0435 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u0438\u0435 \u0438\u043c\u0435\u043d\u0438 \u043f\u0443\u0442\u0438 \u043a \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u0443 \u0441 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0435\u043d\u043d\u044b\u043c \u0434\u043e\u0441\u0442\u0443\u043f\u043e\u043c (\u00ab\u041e\u0431\u0445\u043e\u0434 \u043f\u0443\u0442\u0438\u00bb) (CWE-22), \u041e\u0431\u0445\u043e\u0434 \u043e\u0442\u043d\u043e\u0441\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0443\u0442\u0438 (CWE-23)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0435\u0445\u0430\u043d\u0438\u0437\u043c\u0430 \u0437\u0430\u0433\u0440\u0443\u0437\u043a\u0438 \u0444\u0430\u0439\u043b\u043e\u0432 \u0432\u0435\u0431-\u0441\u0435\u0440\u0432\u0435\u0440\u0430 CivetWeb \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043e\u0448\u0438\u0431\u043a\u0430\u043c\u0438 \u0432 \u043e\u0431\u0440\u0430\u0431\u043e\u0442\u043a\u0435 \u043e\u0442\u043d\u043e\u0441\u0438\u0442\u0435\u043b\u044c\u043d\u043e\u0433\u043e \u043f\u0443\u0442\u0438 \u043a \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u0443. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0451\u043d\u043d\u043e, \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434, \u043f\u0443\u0442\u0435\u043c \u043e\u0442\u043f\u0440\u0430\u0432\u043a\u0438 \u0441\u043f\u0435\u0446\u0438\u0430\u043b\u044c\u043d\u043e \u0441\u0444\u043e\u0440\u043c\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e HTTP-\u0437\u0430\u043f\u0440\u043e\u0441\u0430",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://nvd.nist.gov/vuln/detail/CVE-2020-27304\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf \nhttps://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf\nhttps://groups.google.com/g/civetweb/c/yPBxNXdGgJQ \nhttps://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/\nhttps://www.cybersecurity-help.cz/vdb/SB2022061528",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u0421\u0435\u0442\u0435\u0432\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e, \u0421\u0435\u0442\u0435\u0432\u043e\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e, \u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-22, CWE-23",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 10)\n\u041a\u0440\u0438\u0442\u0438\u0447\u0435\u0441\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 9,8)"
}
GSD-2020-27304
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2020-27304",
"description": "The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal",
"id": "GSD-2020-27304",
"references": [
"https://www.suse.com/security/cve/CVE-2020-27304.html",
"https://access.redhat.com/errata/RHSA-2021:4902"
]
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-27304"
],
"details": "The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal",
"id": "GSD-2020-27304",
"modified": "2023-12-13T01:22:10.864133Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "vuln@vdoo.com",
"ID": "CVE-2020-27304",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "civetweb",
"version": {
"version_data": [
{
"version_affected": "!\u003e=",
"version_value": "1.15"
},
{
"version_affected": "\u003e=",
"version_value": "1.8"
}
]
}
}
]
},
"vendor_name": "civetweb_project"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-23"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/",
"refsource": "MISC",
"url": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/"
},
{
"name": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ",
"refsource": "MISC",
"url": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:civetweb_project:civetweb:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.15",
"versionStartIncluding": "1.8",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.0.1.1",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "vuln@vdoo.com",
"ID": "CVE-2020-27304"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/",
"refsource": "MISC",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/"
},
{
"name": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ",
"refsource": "MISC",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf",
"refsource": "CONFIRM",
"tags": [],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-06-14T11:15Z",
"publishedDate": "2021-10-21T16:15Z"
}
}
}
GHSA-WPHM-MH7C-38CF
Vulnerability from github – Published: 2022-05-24 19:18 – Updated: 2022-05-24 19:18The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal
{
"affected": [],
"aliases": [
"CVE-2020-27304"
],
"database_specific": {
"cwe_ids": [
"CWE-22"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-10-21T16:15:00Z",
"severity": "CRITICAL"
},
"details": "The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal",
"id": "GHSA-wphm-mh7c-38cf",
"modified": "2022-05-24T19:18:28Z",
"published": "2022-05-24T19:18:28Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-27304"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"type": "WEB",
"url": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ"
},
{
"type": "WEB",
"url": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
FKIE_CVE-2020-27304
Vulnerability from fkie_nvd - Published: 2021-10-21 16:15 - Updated: 2024-11-21 05:21| URL | Tags | ||
|---|---|---|---|
| vuln@vdoo.com | https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf | ||
| vuln@vdoo.com | https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf | Patch, Third Party Advisory | |
| vuln@vdoo.com | https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ | Mailing List, Third Party Advisory | |
| vuln@vdoo.com | https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/ | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf | Patch, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ | Mailing List, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/ | Exploit, Third Party Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| civetweb_project | civetweb | * | |
| siemens | sinec_infrastructure_network_services | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:civetweb_project:civetweb:*:*:*:*:*:*:*:*",
"matchCriteriaId": "86B4245C-5C12-424B-A771-E04CE3516108",
"versionEndExcluding": "1.15",
"versionStartIncluding": "1.8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:sinec_infrastructure_network_services:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B0F46497-4AB0-49A7-9453-CC26837BF253",
"versionEndExcluding": "1.0.1.1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "The CivetWeb web library does not validate uploaded filepaths when running on an OS other than Windows, when using the built-in HTTP form-based file upload mechanism, via the mg_handle_form_request API. Web applications that use the file upload form handler, and use parts of the user-controlled filename in the output path, are susceptible to directory traversal"
},
{
"lang": "es",
"value": "La biblioteca web CivetWeb no comprueba las rutas de los archivos cargados cuando se ejecuta en un sistema operativo distinto de Windows, cuando es usado el mecanismo incorporado de carga de archivos basado en formularios HTTP, por medio de la API mg_handle_form_request. Las aplicaciones web que usan el manejador de formularios de carga de archivos, y usan partes del nombre de archivo controlado por el usuario en la ruta de salida, son susceptibles a un salto de directorio"
}
],
"id": "CVE-2020-27304",
"lastModified": "2024-11-21T05:21:01.317",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 7.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-10-21T16:15:07.737",
"references": [
{
"source": "vuln@vdoo.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf"
},
{
"source": "vuln@vdoo.com",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"source": "vuln@vdoo.com",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ"
},
{
"source": "vuln@vdoo.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-222547.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-389290.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mailing List",
"Third Party Advisory"
],
"url": "https://groups.google.com/g/civetweb/c/yPBxNXdGgJQ"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://jfrog.com/blog/cve-2020-27304-rce-via-directory-traversal-in-civetweb-http-server/"
}
],
"sourceIdentifier": "vuln@vdoo.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-23"
}
],
"source": "vuln@vdoo.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.