Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-35684 (GCVE-0-2020-35684)
Vulnerability from cvelistv5 – Published: 2021-08-19 11:19 – Updated: 2024-08-04 17:09- n/a
| URL | Tags | |||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T17:09:14.969Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.hcc-embedded.com"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/"
},
{
"name": "VU#608209",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN",
"x_transferred"
],
"url": "https://www.kb.cert.org/vuls/id/608209"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible)."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-08-19T11:19:27.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.hcc-embedded.com"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/"
},
{
"name": "VU#608209",
"tags": [
"third-party-advisory",
"x_refsource_CERT-VN"
],
"url": "https://www.kb.cert.org/vuls/id/608209"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-35684",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.hcc-embedded.com",
"refsource": "MISC",
"url": "https://www.hcc-embedded.com"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
},
{
"name": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/",
"refsource": "MISC",
"url": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/"
},
{
"name": "VU#608209",
"refsource": "CERT-VN",
"url": "https://www.kb.cert.org/vuls/id/608209"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2020-35684",
"datePublished": "2021-08-19T11:19:01.000Z",
"dateReserved": "2020-12-24T00:00:00.000Z",
"dateUpdated": "2024-08-04T17:09:14.969Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
GSD-2020-35684
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2020-35684",
"description": "An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible).",
"id": "GSD-2020-35684",
"references": [
"https://www.suse.com/security/cve/CVE-2020-35684.html"
]
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-35684"
],
"details": "An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible).",
"id": "GSD-2020-35684",
"modified": "2023-12-13T01:22:01.209927Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-35684",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.hcc-embedded.com",
"refsource": "MISC",
"url": "https://www.hcc-embedded.com"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
},
{
"name": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/",
"refsource": "MISC",
"url": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/"
},
{
"name": "VU#608209",
"refsource": "CERT-VN",
"url": "https://www.kb.cert.org/vuls/id/608209"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:hcc-embedded:nichestack:3.0:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:sentron_3wl_com35_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:sentron_3wl_com35:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:sentron_3wa_com190_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.0.0",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:sentron_3wa_com190:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2020-35684"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible)."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf",
"refsource": "CONFIRM",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
},
{
"name": "https://www.hcc-embedded.com",
"refsource": "MISC",
"tags": [
"Product"
],
"url": "https://www.hcc-embedded.com"
},
{
"name": "VU#608209",
"refsource": "CERT-VN",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.kb.cert.org/vuls/id/608209"
},
{
"name": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/",
"refsource": "MISC",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2021-08-26T18:21Z",
"publishedDate": "2021-08-19T12:15Z"
}
}
}
GHSA-748V-RHFV-4HM6
Vulnerability from github – Published: 2022-05-24 19:11 – Updated: 2022-05-24 19:11An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible).
{
"affected": [],
"aliases": [
"CVE-2020-35684"
],
"database_specific": {
"cwe_ids": [
"CWE-20"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-08-19T12:15:00Z",
"severity": "HIGH"
},
"details": "An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible).",
"id": "GHSA-748v-rhfv-4hm6",
"modified": "2022-05-24T19:11:42Z",
"published": "2022-05-24T19:11:42Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-35684"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
},
{
"type": "WEB",
"url": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack"
},
{
"type": "WEB",
"url": "https://www.hcc-embedded.com"
},
{
"type": "WEB",
"url": "https://www.kb.cert.org/vuls/id/608209"
}
],
"schema_version": "1.4.0",
"severity": []
}
CERTFR-2022-AVI-815
Vulnerability from certfr_avis - Published: 2022-09-13 - Updated: 2022-09-13
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Elles permettent à un attaquant de provoquer une exécution de code arbitraire, un déni de service et une atteinte à la confidentialité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | Modicon MC80 sans le correctif de sécurité BMKC8020301 | ||
| N/A | N/A | CANopen X80 Communication Module (BMECXM0100) toutes versions | ||
| Schneider Electric | N/A | Modicon MC80 (BMKC80) versions antérieures à 1.8 | ||
| Schneider Electric | N/A | Modicon MC80 Controller (BMKC8*) versions antérieures à 1.8 | ||
| Schneider Electric | Modicon M340 | Modicon M340 X80 Ethernet Communication Modules BMXNOE0110 (H) toutes versions | ||
| Schneider Electric | Modicon M340 | Modicon M340 X80 Ethernet Communication Modules BMXNOE0100 (H) toutes versions | ||
| N/A | N/A | EcoStruxure™ Control Expert version 15.1 sans le dernier correctif de sécurité | ||
| Schneider Electric | N/A | Modicon RTU BMXNOR0200H versions antérieures à 1.7 IR24 | ||
| Schneider Electric | Modicon M340 | Modicon M340 X80 Ethernet Communication Module BMXNOR0200H RTU versions antérieures à 1.7 IR24 | ||
| Schneider Electric | Modicon M340 | Modicon M340 Ethernet TCP/IP Network Module BMXNOC0401 versions antérieures à 2.11 | ||
| Schneider Electric | N/A | Profibus Remote Master (TCSEGPA23F14F) toutes versions | ||
| Schneider Electric | N/A | Lexium ILE ILA ILS Communication Drive versions antérieures à 01.110 | ||
| Schneider Electric | Modicon M340 | Modicon M340 X80 Ethernet Communication module BMXNOC0401 versions antérieures à version 2.11 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Modicon MC80 sans le correctif de s\u00e9curit\u00e9 BMKC8020301",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "CANopen X80 Communication Module (BMECXM0100) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon MC80 (BMKC80) versions ant\u00e9rieures \u00e0 1.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon MC80 Controller (BMKC8*) versions ant\u00e9rieures \u00e0 1.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 X80 Ethernet Communication Modules BMXNOE0110 (H) toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 X80 Ethernet Communication Modules BMXNOE0100 (H) toutes versions",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "EcoStruxure\u2122 Control Expert version 15.1 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon RTU BMXNOR0200H versions ant\u00e9rieures \u00e0 1.7 IR24",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 X80 Ethernet Communication Module BMXNOR0200H RTU versions ant\u00e9rieures \u00e0 1.7 IR24",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 Ethernet TCP/IP Network Module BMXNOC0401 versions ant\u00e9rieures \u00e0 2.11",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Profibus Remote Master (TCSEGPA23F14F) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Lexium ILE ILA ILS Communication Drive versions ant\u00e9rieures \u00e0 01.110",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 X80 Ethernet Communication module BMXNOC0401 versions ant\u00e9rieures \u00e0 version 2.11",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-7564",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7564"
},
{
"name": "CVE-2020-7563",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7563"
},
{
"name": "CVE-2020-7535",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7535"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2020-7549",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7549"
},
{
"name": "CVE-2021-31401",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31401"
},
{
"name": "CVE-2022-37301",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37301"
},
{
"name": "CVE-2018-7241",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7241"
},
{
"name": "CVE-2022-0222",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0222"
},
{
"name": "CVE-2018-7242",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7242"
},
{
"name": "CVE-2021-31400",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31400"
},
{
"name": "CVE-2021-22788",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22788"
},
{
"name": "CVE-2020-35685",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35685"
},
{
"name": "CVE-2020-7562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7562"
},
{
"name": "CVE-2020-35683",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35683"
},
{
"name": "CVE-2020-35684",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35684"
},
{
"name": "CVE-2020-7536",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7536"
},
{
"name": "CVE-2018-7857",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7857"
},
{
"name": "CVE-2019-6807",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6807"
},
{
"name": "CVE-2018-7240",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7240"
},
{
"name": "CVE-2011-4859",
"url": "https://www.cve.org/CVERecord?id=CVE-2011-4859"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2021-22787",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22787"
},
{
"name": "CVE-2021-22785",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22785"
}
],
"initial_release_date": "2022-09-13T00:00:00",
"last_revision_date": "2022-09-13T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_Badalloc_Vulnerabilities_Security_Notification_V11.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-257-02 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-257-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-257-02_Web_Server_Modicon_M340_Quantum_and_Premium_and_Communication_Modules_V2.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2018-081-01 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2018-081-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2018-081-01_Embedded_FTP_Servers_for_Modicon_PAC_Controllers_Security_Notification_V4.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2020-343-06 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-343-06\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2020-343-06_Web_Server_Modicon_M340_Premium_Quantum_Communication_Modules_Security_Notification_V2.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2020-343-07 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-343-07\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2020-343-07_SNMP_Service_Modicon_M340_CPU_Security_Notification_V2.1.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-217-01 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-217-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-217-01_NicheStack_Security_Notification_V3.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2019-134-11 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-134-11\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2019-134-11_Modicon_Controllers_Security_Notification_V7.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-221-02 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-221-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-221-02_Modicon_Controllers_Security_Notification_V2.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SESB-2019-214-01 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SESB-2019-214-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SESB-2019-214-01_Wind_River_VxWorks_Security_Bulletin_V2.14.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2020-315-01 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-315-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2020-315-01_Modicon_Web_Server_Security_Notification_V3.0.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2020-343-05 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2020-343-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2020-343-05-Web_Server_Modicon_M340_Premium_Quantum_Communication_Modules_Security_Notification_V2.1.pdf"
}
],
"reference": "CERTFR-2022-AVI-815",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-09-13T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de\ncode arbitraire, un d\u00e9ni de service et une atteinte \u00e0 la confidentialit\u00e9\ndes donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2022-256-01 du 13 septembre 2022",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2022-256-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2022-256-01-EcoStruxure_Machine_SCADA_ExpertPro-face_BLUE_Open_Studio_Security_Notification.pdf"
}
]
}
CERTFR-2023-AVI-0363
Vulnerability from certfr_avis - Published: 2023-05-09 - Updated: 2023-05-09
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer un problème de sécurité non spécifié par l'éditeur, une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| N/A | N/A | OPC Factory Server (OFS) versions antérieures à V3.63SP2 | ||
| N/A | N/A | Modicon X80 Module (part number BMXNOM0200) versions antérieures à V1.60 | ||
| N/A | N/A | PowerLogic PM8000 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | PowerLogic ION7400 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | EcoStruxure Power Operation versions 2022 antérieures à 2022 CU1 | ||
| N/A | N/A | EcoStruxure Power Operation versions 2021 antérieures à 2021 CU3 | ||
| N/A | N/A | Produits Legacy ION toutes versions | ||
| N/A | N/A | PowerLogic ION9000 antérieures à 4.0.0 sans le dernier correctif de sécurité | ||
| N/A | N/A | Power SCADA Anywhere versions 1.1 et 1.2 antérieures à Plant SCADA Anywhere version 2023 | ||
| N/A | N/A | PowerLogic ION8650 toutes versions | ||
| N/A | N/A | Altivar 32/320 et Lexium 32 Ethernet TCP/IP communication module (VW3A3616) versions antérieures à V1.20IE01 | ||
| N/A | N/A | EcoStruxure Power SCADA Operation versions 2020 R2 | ||
| N/A | N/A | PowerLogic ION8800 toutes versions |
| Title | Publication Time | Tags | ||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "OPC Factory Server (OFS) versions ant\u00e9rieures \u00e0 V3.63SP2",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Modicon X80 Module (part number BMXNOM0200) versions ant\u00e9rieures \u00e0 V1.60",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic PM8000 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION7400 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Operation versions 2022 ant\u00e9rieures \u00e0 2022 CU1",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power Operation versions 2021 ant\u00e9rieures \u00e0 2021 CU3",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Produits Legacy ION toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION9000 ant\u00e9rieures \u00e0 4.0.0 sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Power SCADA Anywhere versions 1.1 et 1.2 ant\u00e9rieures \u00e0 Plant SCADA Anywhere version 2023",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION8650 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "Altivar 32/320 et Lexium 32 Ethernet TCP/IP communication module (VW3A3616) versions ant\u00e9rieures \u00e0 V1.20IE01",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "EcoStruxure Power SCADA Operation versions 2020 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
},
{
"description": "PowerLogic ION8800 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "N/A",
"scada": false
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-23854",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23854"
},
{
"name": "CVE-2020-35198",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35198"
},
{
"name": "CVE-2022-46680",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46680"
},
{
"name": "CVE-2021-31401",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31401"
},
{
"name": "CVE-2021-3711",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3711"
},
{
"name": "CVE-2021-31400",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31400"
},
{
"name": "CVE-2023-1256",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1256"
},
{
"name": "CVE-2020-35685",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35685"
},
{
"name": "CVE-2020-35683",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35683"
},
{
"name": "CVE-2020-35684",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35684"
},
{
"name": "CVE-2020-11022",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-11022"
},
{
"name": "CVE-2020-28895",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28895"
},
{
"name": "CVE-2023-2161",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2161"
}
],
"initial_release_date": "2023-05-09T00:00:00",
"last_revision_date": "2023-05-09T00:00:00",
"links": [],
"reference": "CERTFR-2023-AVI-0363",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-05-09T00:00:00.000000"
},
{
"description": "Ajout des num\u00e9ros de CVE manquants",
"revision_date": "2023-05-09T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
},
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer un probl\u00e8me de s\u00e9curit\u00e9 non sp\u00e9cifi\u00e9 par l\u0027\u00e9diteur, une\nex\u00e9cution de code arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0\ndistance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-01 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-217-01 du 05 ao\u00fbt 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-217-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-217-01_NicheStack_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-03 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-03.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-04 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-04\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-04.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2023-129-02 du 9 mai 2023",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2023-129-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2023-129-02.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2021-313-05 du 09 novembre 2021",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2021-313-05\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2021-313-05_BadAlloc_Vulnerabilities_Security_Notification.pdf"
}
]
}
CERTFR-2021-AVI-599
Vulnerability from certfr_avis - Published: 2021-08-04 - Updated: 2021-08-04
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Elles permettent à un attaquant de provoquer un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Title | Publication Time | Tags | |||
|---|---|---|---|---|---|
|
|||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SENTRON 3WL COM35 versions ant\u00e9rieures \u00e0 1.2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON 7KM PAC Switched Ethernet PROFINET Expansion Module versions ant\u00e9rieures \u00e0 3.0.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON 3WA COM190 versions ant\u00e9rieures \u00e0 2.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-31401",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31401"
},
{
"name": "CVE-2020-35685",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35685"
},
{
"name": "CVE-2020-35683",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35683"
},
{
"name": "CVE-2020-35684",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35684"
}
],
"initial_release_date": "2021-08-04T00:00:00",
"last_revision_date": "2021-08-04T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-599",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-08-04T00:00:00.000000"
}
],
"risks": [
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Elles permettent \u00e0 un attaquant de provoquer un contournement\nde la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens ssa-789208 du 4 ao\u00fbt 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
}
]
}
CNVD-2021-58800
Vulnerability from cnvd - Published: 2021-08-06目前HCC Embedded公司已发布相关补丁,建议相关供应商(涉及嵌入式网络)及时升级更新:https://www.hcc-embedded.com/support/security-advisories
| Name | ['HCC Embedded InterNiche stack <v4.3', 'HCC Embedded NicheLite <v4.3'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-35684"
}
},
"description": "InterNiche Technologies NicheStack\u662f\u4e00\u79cd\u5360\u7528\u7a7a\u95f4\u5c0f\u3001\u7b26\u5408RFC\u6807\u51c6\u7684\u5d4c\u5165\u5f0f\u534f\u8bae\u6808\uff0c\u53ef\u79fb\u690d\u5230\u5546\u4e1a\u6216\u4e13\u6709\u7684\u975eMMU\u64cd\u4f5c\u7cfb\u7edf\u3002\n\nInterNiche Technologies NicheStack\u5b58\u5728\u8f93\u5165\u9a8c\u8bc1\u9519\u8bef\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u7684\u5b58\u5728\u662f\u7531\u4e8e\u5bf9TCP\u7ec4\u4ef6\u4e2d\u7528\u6237\u63d0\u4f9b\u7684\u8f93\u5165\u9a8c\u8bc1\u4e0d\u8db3\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u53ef\u4ee5\u5411\u5e94\u7528\u7a0b\u5e8f\u4f20\u9012\u7279\u5236\u7684\u8f93\u5165\uff0c\u5e76\u6267\u884c\u62d2\u7edd\u670d\u52a1(DoS)\u653b\u51fb\u3002",
"formalWay": "\u76ee\u524dHCC Embedded\u516c\u53f8\u5df2\u53d1\u5e03\u76f8\u5173\u8865\u4e01\uff0c\u5efa\u8bae\u76f8\u5173\u4f9b\u5e94\u5546\uff08\u6d89\u53ca\u5d4c\u5165\u5f0f\u7f51\u7edc\uff09\u53ca\u65f6\u5347\u7ea7\u66f4\u65b0\uff1ahttps://www.hcc-embedded.com/support/security-advisories",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-58800",
"openTime": "2021-08-06",
"patchDescription": "InterNiche Technologies NicheStack\u662f\u4e00\u79cd\u5360\u7528\u7a7a\u95f4\u5c0f\u3001\u7b26\u5408RFC\u6807\u51c6\u7684\u5d4c\u5165\u5f0f\u534f\u8bae\u6808\uff0c\u53ef\u79fb\u690d\u5230\u5546\u4e1a\u6216\u4e13\u6709\u7684\u975eMMU\u64cd\u4f5c\u7cfb\u7edf\u3002\r\n\r\nInterNiche Technologies NicheStack\u5b58\u5728\u8f93\u5165\u9a8c\u8bc1\u9519\u8bef\u6f0f\u6d1e\uff0c\u8be5\u6f0f\u6d1e\u7684\u5b58\u5728\u662f\u7531\u4e8e\u5bf9TCP\u7ec4\u4ef6\u4e2d\u7528\u6237\u63d0\u4f9b\u7684\u8f93\u5165\u9a8c\u8bc1\u4e0d\u8db3\u3002\u8fdc\u7a0b\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u53ef\u4ee5\u5411\u5e94\u7528\u7a0b\u5e8f\u4f20\u9012\u7279\u5236\u7684\u8f93\u5165\uff0c\u5e76\u6267\u884c\u62d2\u7edd\u670d\u52a1(DoS)\u653b\u51fb\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "HCC Embedded InterNiche Technologies NicheStack\u8f93\u5165\u9a8c\u8bc1\u9519\u8bef\u6f0f\u6d1e\uff08CNVD-2021-58800\uff09\u7684\u8865\u4e01",
"products": {
"product": [
"HCC Embedded InterNiche stack \u003cv4.3",
"HCC Embedded NicheLite \u003cv4.3"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf",
"serverity": "\u9ad8",
"submitTime": "2021-08-05",
"title": "HCC Embedded InterNiche Technologies NicheStack\u8f93\u5165\u9a8c\u8bc1\u9519\u8bef\u6f0f\u6d1e\uff08CNVD-2021-58800\uff09"
}
FKIE_CVE-2020-35684
Vulnerability from fkie_nvd - Published: 2021-08-19 12:15 - Updated: 2024-11-21 05:27| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf | Mitigation, Third Party Advisory | |
| cve@mitre.org | https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/ | Mitigation, Third Party Advisory | |
| cve@mitre.org | https://www.hcc-embedded.com | Product | |
| cve@mitre.org | https://www.kb.cert.org/vuls/id/608209 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf | Mitigation, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/ | Mitigation, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.hcc-embedded.com | Product | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.kb.cert.org/vuls/id/608209 | Third Party Advisory, US Government Resource |
| Vendor | Product | Version | |
|---|---|---|---|
| hcc-embedded | nichestack | 3.0 | |
| siemens | sentron_3wl_com35_firmware | * | |
| siemens | sentron_3wl_com35 | - | |
| siemens | sentron_3wa_com190_firmware | * | |
| siemens | sentron_3wa_com190 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:hcc-embedded:nichestack:3.0:*:*:*:*:*:*:*",
"matchCriteriaId": "22916BA2-C530-46C0-9C4E-1C0342C9089E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sentron_3wl_com35_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "438332F0-E222-48FB-BA95-0A79EAC9E448",
"versionEndExcluding": "1.2.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sentron_3wl_com35:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AF6988F4-8734-4B27-AD0B-B91F25654F9A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sentron_3wa_com190_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B62056DC-DF99-4118-9B22-45E51980CD7F",
"versionEndExcluding": "2.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sentron_3wa_com190:-:*:*:*:*:*:*:*",
"matchCriteriaId": "797EAA6F-5E8C-4855-87ED-CE4D76D02571",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered in HCC Nichestack 3.0. The code that parses TCP packets relies on an unchecked value of the IP payload size (extracted from the IP header) to compute the length of the TCP payload within the TCP checksum computation function. When the IP payload size is set to be smaller than the size of the IP header, the TCP checksum computation function may read out of bounds (a low-impact write-out-of-bounds is also possible)."
},
{
"lang": "es",
"value": "Se ha detectado un problema en HCC Nichestack versi\u00f3n 3.0. El c\u00f3digo que analiza los paquetes TCP se basa en un valor no comprobado del tama\u00f1o de la carga \u00fatil IP (extra\u00eddo del encabezado IP) para calcular la longitud de la carga \u00fatil TCP dentro de la funci\u00f3n de c\u00e1lculo de la suma de comprobaci\u00f3n TCP. Cuando el tama\u00f1o de la carga \u00fatil IP est\u00e1 configurado para ser menor que el tama\u00f1o del encabezado IP, la funci\u00f3n de c\u00e1lculo de la suma de comprobaci\u00f3n TCP puede leer fuera de l\u00edmites (tambi\u00e9n es posible una escritura fuera de l\u00edmites de bajo impacto)."
}
],
"id": "CVE-2020-35684",
"lastModified": "2024-11-21T05:27:50.820",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-08-19T12:15:08.020",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
},
{
"source": "cve@mitre.org",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/"
},
{
"source": "cve@mitre.org",
"tags": [
"Product"
],
"url": "https://www.hcc-embedded.com"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.kb.cert.org/vuls/id/608209"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-789208.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Third Party Advisory"
],
"url": "https://www.forescout.com/blog/new-critical-operational-technology-vulnerabilities-found-on-nichestack/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.hcc-embedded.com"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://www.kb.cert.org/vuls/id/608209"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2020-35684
Vulnerability from fstec - Published: 28.05.2021{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "HCC Embedded",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 4.3 (NicheLite), \u0434\u043e 4.3 (InterNiche)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://www.hcc-embedded.com/support/security-advisories",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "28.05.2021",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "15.09.2021",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "15.09.2021",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2021-04494",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2020-35684",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "NicheLite, InterNiche",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u0444\u0443\u043d\u043a\u0446\u0438\u0438 TCP checksum \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u0430 TCP \u0441\u0442\u0435\u043a\u043e\u0432 TCP/IP NicheLite \u0438 InterNiche, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u0430\u044f \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u0430 \u0432\u0432\u043e\u0434\u0438\u043c\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445 (CWE-20)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0440\u0435\u0430\u043b\u0438\u0437\u0430\u0446\u0438\u0438 \u0444\u0443\u043d\u043a\u0446\u0438\u0438 TCP checksum \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u0430 TCP \u0441\u0442\u0435\u043a\u043e\u0432 TCP/IP NicheLite \u0438 InterNiche \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u0434\u043e\u0441\u0442\u0430\u0442\u043e\u0447\u043d\u043e\u0439 \u043f\u0440\u043e\u0432\u0435\u0440\u043a\u043e\u0439 \u0432\u0445\u043e\u0434\u043d\u044b\u0445 \u0434\u0430\u043d\u043d\u044b\u0445. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://www.cybersecurity-help.cz/vdb/SB2021080607\nhttps://us-cert.cisa.gov/ics/advisories/icsa-21-217-01\nhttps://www.cisecurity.org/advisory/multiple-vulnerabilities-in-nichestack-could-allow-for-remote-code-execution/\nhttps://xakep.ru/2021/08/04/infra-halt/\nhttps://www.hcc-embedded.com/support/security-advisories",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u0421\u0435\u0442\u0435\u0432\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e, \u0421\u0435\u0442\u0435\u0432\u043e\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-20",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.