CVE-2021-33842 (GCVE-0-2021-33842)
Vulnerability from cvelistv5 – Published: 2021-06-09 11:39 – Updated: 2024-09-16 20:01
VLAI?
Title
Circutor SGE-PLC1000 improper authentication
Summary
Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located.
Severity ?
8.8 (High)
CWE
- CWE-565 - Reliance on Cookies without Validation and Integrity Checking
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Circutor | SGE-PLC1000 |
Affected:
0.9.2b
|
Credits
Industrial Cybersecurity team of S21sec, special mention to Aarón Flecha Menéndez.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:58:23.180Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SGE-PLC1000",
"vendor": "Circutor",
"versions": [
{
"status": "affected",
"version": "0.9.2b"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Industrial Cybersecurity team of S21sec, special mention to Aar\u00f3n Flecha Men\u00e9ndez."
}
],
"datePublic": "2021-06-07T22:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located."
}
],
"value": "Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-565",
"description": "CWE-565 Reliance on Cookies without Validation and Integrity Checking",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-11-23T13:47:01.158Z",
"orgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"shortName": "INCIBE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://www.incibe.es/en/incibe-cert/notices/aviso-sci/circutor-sge-plc1000-improper-authentication"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
}
],
"value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
}
],
"source": {
"advisory": "INCIBE-2021-0228",
"discovery": "EXTERNAL"
},
"title": "Circutor SGE-PLC1000 improper authentication",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cve-coordination@incibe.es",
"DATE_PUBLIC": "2021-06-08T08:00:00.000Z",
"ID": "CVE-2021-33842",
"STATE": "PUBLIC",
"TITLE": "Circutor SGE-PLC1000 improper authentication"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SGE-PLC1000",
"version": {
"version_data": [
{
"version_affected": "=",
"version_name": "0.9.2b",
"version_value": "0.9.2b"
}
]
}
}
]
},
"vendor_name": "Circutor"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Industrial Cybersecurity team of S21sec, special mention to Aar\u00f3n Flecha Men\u00e9ndez."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "Improper Authentication vulnerability in the cookie parameter of Circutor SGE-PLC1000 firmware version 0.9.2b allows an attacker to perform operations as an authenticated user. In order to exploit this vulnerability, the attacker must be within the network where the device affected is located."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-287: Improper Authentication"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-improper-authentication",
"refsource": "CONFIRM",
"url": "https://www.incibe-cert.es/en/early-warning/ics-advisories/circutor-sge-plc1000-improper-authentication"
}
]
},
"solution": [
{
"lang": "en",
"value": "This issue can be solved through a firmware upgrade that has already been released by the vendor."
}
],
"source": {
"advisory": "INCIBE-2021-0228",
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "0cbda920-cd7f-484a-8e76-bf7f4b7f4516",
"assignerShortName": "INCIBE",
"cveId": "CVE-2021-33842",
"datePublished": "2021-06-09T11:39:52.302Z",
"dateReserved": "2021-06-04T00:00:00.000Z",
"dateUpdated": "2024-09-16T20:01:18.942Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…