CVE-2021-34601 (GCVE-0-2021-34601)
Vulnerability from cvelistv5 – Published: 2022-04-27 15:15 – Updated: 2024-09-16 19:47
VLAI?
Title
Bender Charge Controller: Hardcoded Credentials in Charge Controller
Summary
In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the password to gain administrative access to the web-UI.
Severity ?
9.8 (Critical)
CWE
- CWE-259 - Use of Hard-coded Password
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Bender / ebee | CC612 |
Affected:
5.11.x , < 5.11.2
(custom)
Affected: 5.12.x , < 5.12.5 (custom) Affected: 5.13.x , < 5.13.2 (custom) Affected: 5.20.x , < 5.20.2 (custom) |
|||||||||||||||||
|
|||||||||||||||||||
Credits
Bender thanks Qianxin StarV Security Lab, China. The issue was coordinated by CERT@VDE.
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T00:19:47.864Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-047"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "CC612",
"vendor": "Bender / ebee",
"versions": [
{
"lessThan": "5.11.2",
"status": "affected",
"version": "5.11.x",
"versionType": "custom"
},
{
"lessThan": "5.12.5",
"status": "affected",
"version": "5.12.x",
"versionType": "custom"
},
{
"lessThan": "5.13.2",
"status": "affected",
"version": "5.13.x",
"versionType": "custom"
},
{
"lessThan": "5.20.2",
"status": "affected",
"version": "5.20.x",
"versionType": "custom"
}
]
},
{
"product": "CC613",
"vendor": "Bender / ebee",
"versions": [
{
"lessThan": "5.11.2",
"status": "affected",
"version": "5.11.x",
"versionType": "custom"
},
{
"lessThan": "5.12.5",
"status": "affected",
"version": "5.12.x",
"versionType": "custom"
},
{
"lessThan": "5.13.2",
"status": "affected",
"version": "5.13.x",
"versionType": "custom"
},
{
"lessThan": "5.20.2",
"status": "affected",
"version": "5.20.x",
"versionType": "custom"
}
]
},
{
"product": "ICC15xx",
"vendor": "Bender / ebee",
"versions": [
{
"lessThan": "5.11.2",
"status": "affected",
"version": "5.11.x",
"versionType": "custom"
},
{
"lessThan": "5.12.5",
"status": "affected",
"version": "5.12.x",
"versionType": "custom"
},
{
"lessThan": "5.13.2",
"status": "affected",
"version": "5.13.x",
"versionType": "custom"
},
{
"lessThan": "5.20.2",
"status": "affected",
"version": "5.20.x",
"versionType": "custom"
}
]
},
{
"product": "ICC16xx",
"vendor": "Bender / ebee",
"versions": [
{
"lessThan": "5.11.2",
"status": "affected",
"version": "5.11.x",
"versionType": "custom"
},
{
"lessThan": "5.12.5",
"status": "affected",
"version": "5.12.x",
"versionType": "custom"
},
{
"lessThan": "5.13.2",
"status": "affected",
"version": "5.13.x",
"versionType": "custom"
},
{
"lessThan": "5.20.2",
"status": "affected",
"version": "5.20.x",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Bender thanks Qianxin StarV Security Lab, China. The issue was coordinated by CERT@VDE."
}
],
"datePublic": "2022-04-27T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the password to gain administrative access to the web-UI."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-259",
"description": "CWE-259 Use of Hard-coded Password",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-27T15:15:33.000Z",
"orgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"shortName": "CERTVDE"
},
"references": [
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert.vde.com/en/advisories/VDE-2021-047"
}
],
"source": {
"advisory": "VDE-2021-047",
"defect": [
"CERT@VDE#64026"
],
"discovery": "EXTERNAL"
},
"title": "Bender Charge Controller: Hardcoded Credentials in Charge Controller",
"x_generator": {
"engine": "Vulnogram 0.0.9"
},
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "info@cert.vde.com",
"DATE_PUBLIC": "2022-04-27T10:00:00.000Z",
"ID": "CVE-2021-34601",
"STATE": "PUBLIC",
"TITLE": "Bender Charge Controller: Hardcoded Credentials in Charge Controller"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "CC612",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "5.11.x",
"version_value": "5.11.2"
},
{
"version_affected": "\u003c",
"version_name": "5.12.x",
"version_value": "5.12.5"
},
{
"version_affected": "\u003c",
"version_name": "5.13.x",
"version_value": "5.13.2"
},
{
"version_affected": "\u003c",
"version_name": "5.20.x",
"version_value": "5.20.2"
}
]
}
},
{
"product_name": "CC613",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "5.11.x",
"version_value": "5.11.2"
},
{
"version_affected": "\u003c",
"version_name": "5.12.x",
"version_value": "5.12.5"
},
{
"version_affected": "\u003c",
"version_name": "5.13.x",
"version_value": "5.13.2"
},
{
"version_affected": "\u003c",
"version_name": "5.20.x",
"version_value": "5.20.2"
}
]
}
},
{
"product_name": "ICC15xx",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "5.11.x",
"version_value": "5.11.2"
},
{
"version_affected": "\u003c",
"version_name": "5.12.x",
"version_value": "5.12.5"
},
{
"version_affected": "\u003c",
"version_name": "5.13.x",
"version_value": "5.13.2"
},
{
"version_affected": "\u003c",
"version_name": "5.20.x",
"version_value": "5.20.2"
}
]
}
},
{
"product_name": "ICC16xx",
"version": {
"version_data": [
{
"version_affected": "\u003c",
"version_name": "5.11.x",
"version_value": "5.11.2"
},
{
"version_affected": "\u003c",
"version_name": "5.12.x",
"version_value": "5.12.5"
},
{
"version_affected": "\u003c",
"version_name": "5.13.x",
"version_value": "5.13.2"
},
{
"version_affected": "\u003c",
"version_name": "5.20.x",
"version_value": "5.20.2"
}
]
}
}
]
},
"vendor_name": "Bender / ebee"
}
]
}
},
"credit": [
{
"lang": "eng",
"value": "Bender thanks Qianxin StarV Security Lab, China. The issue was coordinated by CERT@VDE."
}
],
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "In Bender/ebee Charge Controllers in multiple versions are prone to Hardcoded Credentials. Bender charge controller CC612 in version 5.20.1 and below is prone to hardcoded ssh credentials. An attacker may use the password to gain administrative access to the web-UI."
}
]
},
"generator": {
"engine": "Vulnogram 0.0.9"
},
"impact": {
"cvss": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-259 Use of Hard-coded Password"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert.vde.com/en/advisories/VDE-2021-047",
"refsource": "CONFIRM",
"url": "https://cert.vde.com/en/advisories/VDE-2021-047"
}
]
},
"source": {
"advisory": "VDE-2021-047",
"defect": [
"CERT@VDE#64026"
],
"discovery": "EXTERNAL"
}
}
}
},
"cveMetadata": {
"assignerOrgId": "270ccfa6-a436-4e77-922e-914ec3a9685c",
"assignerShortName": "CERTVDE",
"cveId": "CVE-2021-34601",
"datePublished": "2022-04-27T15:15:33.375Z",
"dateReserved": "2021-06-10T00:00:00.000Z",
"dateUpdated": "2024-09-16T19:47:12.796Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…