Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-23448 (GCVE-0-2022-23448)
Vulnerability from cvelistv5 – Published: 2022-04-12 09:07 – Updated: 2024-08-03 03:43- CWE-732 - Incorrect Permission Assignment for Critical Resource
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | SIMATIC Energy Manager Basic |
Affected:
All versions < V7.3 Update 1
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T03:43:45.944Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "SIMATIC Energy Manager Basic",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.3 Update 1"
}
]
},
{
"product": "SIMATIC Energy Manager PRO",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V7.3 Update 1"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-732",
"description": "CWE-732: Incorrect Permission Assignment for Critical Resource",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-04-12T09:07:35.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-23448",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Energy Manager Basic",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Update 1"
}
]
}
},
{
"product_name": "SIMATIC Energy Manager PRO",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Update 1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-23448",
"datePublished": "2022-04-12T09:07:35.000Z",
"dateReserved": "2022-01-19T00:00:00.000Z",
"dateUpdated": "2024-08-03T03:43:45.944Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CNVD-2022-28494
Vulnerability from cnvd - Published: 2022-04-13厂商已发布了漏洞修复程序,请及时关注更新: https://www.siemens.com
| Name | ['Siemens SIMATIC Energy Manager Basic <7.3 Update 1', 'Siemens SIMATIC Energy Manager PRO <7.3 Update 1'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-23448"
}
},
"description": "SIMATIC Energy Manager\u4ee5\u8be6\u7ec6\u5730\u53ef\u89c6\u5316\u8fc7\u7a0b\u4e2d\u7684\u80fd\u91cf\u6d41\u548c\u6d88\u8017\u503c\uff0c\u5c06\u5b83\u4eec\u5206\u914d\u7ed9\u76f8\u5173\u7684\u6d88\u8d39\u8005\u6216\u6210\u672c\u4e2d\u5fc3\uff0c\u5e76\u786e\u5b9a\u53d1\u751f\u53d8\u5316\u7684\u539f\u56e0\u3002\n\nSiemens SIMATIC Energy Manager\u5b58\u5728\u8bbf\u95ee\u63a7\u5236\u9519\u8bef\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u4f7f\u7528ADMINISTRATOR\u751a\u81f3NT AUTHORITY/SYSTEM\u6743\u9650\u6765\u6267\u884c\u4ee3\u7801\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://www.siemens.com",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2022-28494",
"openTime": "2022-04-13",
"patchDescription": "SIMATIC Energy Manager\u4ee5\u8be6\u7ec6\u5730\u53ef\u89c6\u5316\u8fc7\u7a0b\u4e2d\u7684\u80fd\u91cf\u6d41\u548c\u6d88\u8017\u503c\uff0c\u5c06\u5b83\u4eec\u5206\u914d\u7ed9\u76f8\u5173\u7684\u6d88\u8d39\u8005\u6216\u6210\u672c\u4e2d\u5fc3\uff0c\u5e76\u786e\u5b9a\u53d1\u751f\u53d8\u5316\u7684\u539f\u56e0\u3002\r\n\r\nSiemens SIMATIC Energy Manager\u5b58\u5728\u8bbf\u95ee\u63a7\u5236\u9519\u8bef\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u4f7f\u7528ADMINISTRATOR\u751a\u81f3NT AUTHORITY/SYSTEM\u6743\u9650\u6765\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens SIMATIC Energy Manager\u8bbf\u95ee\u63a7\u5236\u9519\u8bef\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens SIMATIC Energy Manager Basic \u003c7.3 Update 1",
"Siemens SIMATIC Energy Manager PRO \u003c7.3 Update 1"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
"serverity": "\u9ad8",
"submitTime": "2022-04-13",
"title": "Siemens SIMATIC Energy Manager\u8bbf\u95ee\u63a7\u5236\u9519\u8bef\u6f0f\u6d1e"
}
GHSA-5HQF-83PF-C8GV
Vulnerability from github – Published: 2022-04-13 00:00 – Updated: 2022-04-20 00:00A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
{
"affected": [],
"aliases": [
"CVE-2022-23448"
],
"database_specific": {
"cwe_ids": [
"CWE-732"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-04-12T09:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.",
"id": "GHSA-5hqf-83pf-c8gv",
"modified": "2022-04-20T00:00:55Z",
"published": "2022-04-13T00:00:33Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-23448"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
CERTFR-2022-AVI-329
Vulnerability from certfr_avis - Published: 2022-04-12 - Updated: 2022-04-12
De multiples vulnérabilités ont été découvertes dans les produits SIEMENS. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance et un déni de service à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SCALANCE X308-2 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X307-3 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMIT Simulation Platform toutes versions | ||
| Siemens | N/A | Gamme SIMATIC S7-300 (y compris CPUs ET200 et variantes SIPLUS) toutes versions | ||
| Siemens | N/A | Gamme SIMATIC S7-400 PN/DP V7 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | SIMATIC CFU DIQ (6ES7655-5PX31-1XX0) toutes versions | ||
| Siemens | N/A | SIMATIC WinAC RTX toutes versions | ||
| Siemens | N/A | SINETPLAN toutes versions | ||
| Siemens | N/A | SIMATIC TDC CP51M1 toutes versions | ||
| Siemens | N/A | SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) versions antérieures à V17 Update 2 | ||
| Siemens | N/A | SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SCALANCE X310 versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE XR324-4M PoE TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC PCS neo (Administration Console) versions antérieures à V3.1 SP1 | ||
| Siemens | N/A | SCALANCE X308-2LD versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2M PoE versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X304-2FE (6GK5304-2BD00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | TIA Portal V15, V15.1, V16 et V17 | ||
| Siemens | N/A | SIMATIC TDC CPU555 toutes versions | ||
| Siemens | N/A | SCALANCE XR324-4M EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | SICAM A8000 CP-8050 (6MF2805-0AA00) versions antérieures à V4.80 | ||
| Siemens | N/A | SIMATIC Energy Manager PRO versions antérieures à V7.3 Update 1 | ||
| Siemens | N/A | SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) versions antérieures à V3.0.0 | ||
| Siemens | N/A | SCALANCE X408-2 (6GK5408-2FD00-2AA2) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2LH versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X307-3LD versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X302-7 EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X308-2LH+ versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) versions antérieures à V16 Update 5 | ||
| Siemens | N/A | SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC STEP 7 (TIA Portal) V15 toutes versions | ||
| Siemens | N/A | SCALANCE X308-2M TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | Mendix Applications using Mendix 9 versions antérieures à V9.12.0 | ||
| Siemens | N/A | SCALANCE XR324-12M TS versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X310FE versions antérieures à V4.1.4 | ||
| Siemens | N/A | SCALANCE X307-2 EEC versions antérieures à V4.1.4 | ||
| Siemens | N/A | Simcenter Femap versions antérieures à V2022.1. | ||
| Siemens | N/A | SCALANCE XR324-12M versions antérieures à V4.1.4 | ||
| Siemens | N/A | Gamme SIMATIC S7-410 V8 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | Gamme SIMATIC S7-1500 (y compris CPUs ET200 et variantes SIPLUS) versions antérieures à V2.0.0 | ||
| Siemens | N/A | Mendix Applications using Mendix 7 versions antérieures à V7.23.27 (ne corrige pas toutes les CVE) | ||
| Siemens | N/A | SCALANCE X308-2M versions antérieures à V4.1.4 | ||
| Siemens | N/A | Gamme SIMATIC S7-400 H V6 (y compris variantes SIPLUS) versions antérieures à V6.0.10 | ||
| Siemens | N/A | SIMATIC CFU PA (6ES7655-5PX11-0XX0) toutes versions | ||
| Siemens | N/A | SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3) versions antérieures à V4.1.4 | ||
| Siemens | N/A | SIMATIC Energy Manager Basic versions antérieures à V7.3 Update 1 | ||
| Siemens | N/A | SICAM A8000 CP-8031 (6MF2803-1AA00) versions antérieures à V4.80 | ||
| Siemens | N/A | Gamme SIMATIC S7-410 V10 (y compris variantes SIPLUS) toutes versions | ||
| Siemens | N/A | Mendix Applications using Mendix 8 versions antérieures à V8.18.14 (ne corrige pas toutes les CVE) |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SCALANCE X308-2 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-3 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMIT Simulation Platform toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-300 (y compris CPUs ET200 et variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-400 PN/DP V7 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CFU DIQ (6ES7655-5PX31-1XX0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinAC RTX toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINETPLAN toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CP51M1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X306-1LD FE (6GK5306-1BF00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) versions ant\u00e9rieures \u00e0 V17 Update 2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X310 versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-4M PoE TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS neo (Administration Console) versions ant\u00e9rieures \u00e0 V3.1 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LD versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M PoE versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X304-2FE (6GK5304-2BD00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X320-1-2LD FE (6GK5320-3BF00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Portal V15, V15.1, V16 et V17",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC TDC CPU555 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-4M EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM A8000 CP-8050 (6MF2805-0AA00) versions ant\u00e9rieures \u00e0 V4.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Energy Manager PRO versions ant\u00e9rieures \u00e0 V7.3 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) versions ant\u00e9rieures \u00e0 V3.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X408-2 (6GK5408-2FD00-2AA2) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LH versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-3LD versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X302-7 EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2LH+ versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) versions ant\u00e9rieures \u00e0 V16 Update 5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X320-1 FE (6GK5320-1BD00-2AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 (TIA Portal) V15 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 9 versions ant\u00e9rieures \u00e0 V9.12.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-12M TS versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X310FE versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X307-2 EEC versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter Femap versions ant\u00e9rieures \u00e0 V2022.1.",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324-12M versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-410 V8 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-1500 (y compris CPUs ET200 et variantes SIPLUS) versions ant\u00e9rieures \u00e0 V2.0.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 7 versions ant\u00e9rieures \u00e0 V7.23.27 (ne corrige pas toutes les CVE)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X308-2M versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-400 H V6 (y compris variantes SIPLUS) versions ant\u00e9rieures \u00e0 V6.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC CFU PA (6ES7655-5PX11-0XX0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE X308-2 (6AG1308-2FL10-4AA3) versions ant\u00e9rieures \u00e0 V4.1.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Energy Manager Basic versions ant\u00e9rieures \u00e0 V7.3 Update 1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM A8000 CP-8031 (6MF2803-1AA00) versions ant\u00e9rieures \u00e0 V4.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Gamme SIMATIC S7-410 V10 (y compris variantes SIPLUS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 8 versions ant\u00e9rieures \u00e0 V8.18.14 (ne corrige pas toutes les CVE)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-27241",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27241"
},
{
"name": "CVE-2022-26380",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26380"
},
{
"name": "CVE-2022-27194",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27194"
},
{
"name": "CVE-2022-25754",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25754"
},
{
"name": "CVE-2022-28661",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28661"
},
{
"name": "CVE-2022-23448",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23448"
},
{
"name": "CVE-2022-25753",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25753"
},
{
"name": "CVE-2021-40368",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40368"
},
{
"name": "CVE-2022-26335",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26335"
},
{
"name": "CVE-2022-26334",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26334"
},
{
"name": "CVE-2022-23450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23450"
},
{
"name": "CVE-2022-28328",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28328"
},
{
"name": "CVE-2022-27481",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27481"
},
{
"name": "CVE-2022-25756",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25756"
},
{
"name": "CVE-2022-25751",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25751"
},
{
"name": "CVE-2022-28329",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28329"
},
{
"name": "CVE-2022-25650",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25650"
},
{
"name": "CVE-2022-28663",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28663"
},
{
"name": "CVE-2022-27480",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27480"
},
{
"name": "CVE-2022-28662",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28662"
},
{
"name": "CVE-2021-42029",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42029"
},
{
"name": "CVE-2022-25622",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25622"
},
{
"name": "CVE-2022-25752",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25752"
},
{
"name": "CVE-2022-25755",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-25755"
},
{
"name": "CVE-2022-23449",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23449"
}
],
"initial_release_date": "2022-04-12T00:00:00",
"last_revision_date": "2022-04-12T00:00:00",
"links": [],
"reference": "CERTFR-2022-AVI-329",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-04-12T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSIEMENS. Elles permettent \u00e0 un attaquant de provoquer une ex\u00e9cution de\ncode arbitraire \u00e0 distance et un d\u00e9ni de service \u00e0 distance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits SIEMENS",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-446448 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-446448.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-557541 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-557541.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-655554 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-655554.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-414513 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-414513.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-870917 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-870917.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-316850 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-316850.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-836527 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-836527.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-711829 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-711829.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-392912 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-392912.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-350757 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-350757.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-998762 du 12 avril 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-998762.html"
}
]
}
FKIE_CVE-2022-23448
Vulnerability from fkie_nvd - Published: 2022-04-12 09:15 - Updated: 2024-11-21 06:48| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf | Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf | Mitigation, Patch, Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simatic_energy_manager_basic | * | |
| siemens | simatic_energy_manager_basic | 7.3 | |
| siemens | simatic_energy_manager_pro | * | |
| siemens | simatic_energy_manager_pro | 7.3 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2BDBCB2C-E9EB-4AF6-B47A-22B27AE41178",
"versionEndExcluding": "7.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*",
"matchCriteriaId": "1BB78E93-7C0A-4F59-B6EA-3D5A681BFE8F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4B1E608C-3C6F-45FB-86C9-E99E7F21836D",
"versionEndExcluding": "7.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*",
"matchCriteriaId": "34A11AF9-7F0C-4151-8A4D-A8E1BDCBA525",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones anteriores a V7.3 Update 1), SIMATIC Energy Manager PRO (todas las versiones anteriores a V7.3 Update 1). Las aplicaciones afectadas asignan inapropiadamente los permisos a directorios y archivos cr\u00edticos usados por los procesos de la aplicaci\u00f3n. Esto podr\u00eda permitir a un atacante local no privilegiado lograr la ejecuci\u00f3n de c\u00f3digo con privilegios de ADMINISTRADOR o incluso de NT AUTHORITY/SYSTEM"
}
],
"id": "CVE-2022-23448",
"lastModified": "2024-11-21T06:48:34.530",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T09:15:14.233",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GSD-2022-23448
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-23448",
"description": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.",
"id": "GSD-2022-23448"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-23448"
],
"details": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.",
"id": "GSD-2022-23448",
"modified": "2023-12-13T01:19:35.224239Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-23448",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "SIMATIC Energy Manager Basic",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Update 1"
}
]
}
},
{
"product_name": "SIMATIC Energy Manager PRO",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V7.3 Update 1"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-732: Incorrect Permission Assignment for Critical Resource"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "7.3",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "7.3",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-23448"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "HIGH",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2022-04-19T16:01Z",
"publishedDate": "2022-04-12T09:15Z"
}
}
}
CVE-2022-23448
Vulnerability from fstec - Published: 12.04.2022{
"CVSS 2.0": "AV:L/AC:L/Au:S/C:C/I:C/A:C",
"CVSS 3.0": "AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Siemens AG",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 7.3 Update 1 (SIMATIC Energy Manager Basic), \u0434\u043e 7.3 Update 1 (SIMATIC Energy Manager PRO)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "12.04.2022",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "13.07.2022",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "13.07.2022",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2022-04368",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-23448",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "SIMATIC Energy Manager Basic, SIMATIC Energy Manager PRO",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u044d\u043d\u0435\u0440\u0433\u043e\u043c\u0435\u043d\u0435\u0434\u0436\u043c\u0435\u043d\u0442\u0430 SIMATIC Energy Manager Basic \u0438 SIMATIC Energy Manager PRO, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043f\u0440\u0438\u0441\u0432\u043e\u0435\u043d\u0438\u0435\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0435\u0441\u0443\u0440\u0441\u0430, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0435 \u043f\u0440\u0438\u0441\u0432\u043e\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0435\u0441\u0443\u0440\u0441\u0430 (CWE-732)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u044d\u043d\u0435\u0440\u0433\u043e\u043c\u0435\u043d\u0435\u0434\u0436\u043c\u0435\u043d\u0442\u0430 SIMATIC Energy Manager Basic \u0438 SIMATIC Energy Manager PRO \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043f\u0440\u0438\u0441\u0432\u043e\u0435\u043d\u0438\u0435\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0435\u0441\u0443\u0440\u0441\u0430. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-732",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 6,8)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,3)"
}
CVE-2022-23448
Vulnerability from fstec - Published: 19.01.2022{
"CVSS 2.0": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"CVSS 3.0": "AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Siemens AG",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "\u0434\u043e 7.3 Update 1 (SIMATIC Energy Manager Basic), \u0434\u043e 7.3 Update 1 (SIMATIC Energy Manager PRO)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u0439:\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf\n\n\u041e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0435\u0440\u044b:\n1) \u0421\u043b\u0435\u0434\u0443\u0435\u0442 \u043e\u0433\u0440\u0430\u043d\u0438\u0447\u0438\u0442\u044c \u0434\u043e\u0441\u0442\u0443\u043f \u043a \u043a tcp -\u043f\u043e\u0440\u0442\u0443 4444;\n2) \u0420\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0443\u0435\u0442\u0441\u044f \u0432\u043a\u043b\u044e\u0447\u0438\u0442\u044c \u0448\u0438\u0444\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0432 \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 SIMATIC Energy Manager",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "19.01.2022",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "01.08.2022",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "01.08.2022",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2022-04690",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2022-23448",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0430",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "SIMATIC Energy Manager Basic, SIMATIC Energy Manager PRO",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u044d\u043d\u0435\u0440\u0433\u043e\u043c\u0435\u043d\u0435\u0434\u0436\u043c\u0435\u043d\u0442\u0430 SIMATIC Energy Manager Basic \u0438 SIMATIC Energy Manager PRO, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u0444\u0430\u0439\u043b\u043e\u0432 \u0438 \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u043e\u0432, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u0441\u0432\u043e\u0438 \u043f\u0440\u0438\u0432\u0438\u043b\u0435\u0433\u0438\u0438 \u0438\u043b\u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u043e\u0435 \u043f\u0440\u0438\u0441\u0432\u043e\u0435\u043d\u0438\u0435 \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u043a\u0440\u0438\u0442\u0438\u0447\u043d\u043e\u0433\u043e \u0440\u0435\u0441\u0443\u0440\u0441\u0430 (CWE-732)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0441\u0438\u0441\u0442\u0435\u043c\u044b \u044d\u043d\u0435\u0440\u0433\u043e\u043c\u0435\u043d\u0435\u0434\u0436\u043c\u0435\u043d\u0442\u0430 SIMATIC Energy Manager Basic \u0438 SIMATIC Energy Manager PRO \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043f\u0440\u0430\u0432\u0438\u043b\u044c\u043d\u044b\u043c \u043d\u0430\u0437\u043d\u0430\u0447\u0435\u043d\u0438\u0435\u043c \u0440\u0430\u0437\u0440\u0435\u0448\u0435\u043d\u0438\u0439 \u0434\u043b\u044f \u0444\u0430\u0439\u043b\u043e\u0432 \u0438 \u043a\u0430\u0442\u0430\u043b\u043e\u0433\u043e\u0432. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u043f\u043e\u0432\u044b\u0441\u0438\u0442\u044c \u0441\u0432\u043e\u0438 \u043f\u0440\u0438\u0432\u0438\u043b\u0435\u0433\u0438\u0438 \u0438\u043b\u0438 \u0432\u044b\u043f\u043e\u043b\u043d\u0438\u0442\u044c \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u043b\u044c\u043d\u044b\u0439 \u043a\u043e\u0434",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": null,
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u0435 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://nvd.nist.gov/vuln/detail/cve-2022-23448\nhttps://vuldb.com/?id.196915\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-732",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,2)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,8)"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.