Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2022-43398 (GCVE-0-2022-43398)
Vulnerability from cvelistv5 – Published: 2022-11-08 00:00 – Updated: 2024-08-03 13:32- CWE-384 - Session Fixation
| Vendor | Product | Version | |||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Siemens | POWER METER SICAM Q100 |
Affected:
All versions < V2.50
|
|||||||||||||||||
|
|||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T13:32:58.148Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
},
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q100",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.50"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q100",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.50"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q100",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.50"
}
]
},
{
"defaultStatus": "unknown",
"product": "POWER METER SICAM Q100",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c V2.50"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user\u0027s account through the activated session."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-384",
"description": "CWE-384: Session Fixation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-01-09T09:57:13.900Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2022-43398",
"datePublished": "2022-11-08T00:00:00",
"dateReserved": "2022-10-18T00:00:00",
"dateUpdated": "2024-08-03T13:32:58.148Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
CERTFR-2023-AVI-0453
Vulnerability from certfr_avis - Published: 2023-06-13 - Updated: 2023-06-14
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SINAMICS GL150 versions antérieures à 7.2 | ||
| Siemens | N/A | Teamcenter Visualization versions 13.3.x antérieures à 13.3.0.10 | ||
| Siemens | N/A | SIMOTION D425-2 DP (6AU1425-2AA00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | CP-8050 MASTER MODULE (6MF2805-0AA00) versions antérieures à CPCI85 V05 | ||
| Siemens | N/A | POWER METER SICAM Q200 family versions antérieures à 2.70 | ||
| Siemens | N/A | SIMATIC NET PC Software V15 toutes versions | ||
| Siemens | N/A | SIMOTION D445-2 DP/PN (6AU1445-2AD00-0AA1) toutes versions | ||
| Siemens | N/A | SIMOTION D410-2 DP (6AU1410-2AA00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | SIMATIC STEP 7 V5 versions antérieures à 5.7 | ||
| Siemens | N/A | SIMOTION C240 (6AU1240-1AA00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | SIMATIC S7-1500 TM MFP - Linux Kernel | ||
| Siemens | N/A | SINAUT Software ST7sc toutes versions | ||
| Siemens | N/A | SIMOTION P320-4 E (6AU1320-4DE65-3AF0) toutes versions | ||
| Siemens | N/A | Teamcenter Visualization versions 14.0.x antérieures à 14.0.0.6 | ||
| Siemens | N/A | SIMOTION C240 PN (6AU1240-1AB00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | SIMATIC NET PC Software V14 toutes versions | ||
| Siemens | N/A | SIMATIC PCS 7 V9.0 toutes versions | ||
| Siemens | N/A | SIMATIC PCS 7 V9.1 toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 TM MFP - BIOS | ||
| Siemens | N/A | SIMOTION D435-2 DP/PN (6AU1435-2AD00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | SINAMICS SL150 versions antérieures à 7.2 | ||
| Siemens | N/A | SINAMICS PERFECT HARMONY GH180 6SR5 versions antérieures à 7.2 | ||
| Siemens | N/A | Teamcenter Visualization versions 13.2.x antérieures à 13.2.0.13 | ||
| Siemens | N/A | SIMOTION D435-2 DP (6AU1435-2AA00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | SIMOTION P320-4 S (6AU1320-4DS66-3AG0) toutes versions | ||
| Siemens | N/A | SIMATIC WinCC versions antérieures à 8.0 | ||
| Siemens | N/A | Teamcenter Visualization versions 14.2.x antérieures à 14.2.0.3 | ||
| Siemens | N/A | les contrôlleurs Desigo PX, se référer au bulletin ssa-824231 de l'éditeur pour la liste complète des versions affectées | ||
| Siemens | N/A | SIMOTION D445-2 DP/PN (6AU1445-2AD00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | SIMATIC S7-PM toutes versions | ||
| Siemens | N/A | Solid Edge SE2023 versions antérieures à 223.0 Update 5 | ||
| Siemens | N/A | JT2Go versions antérieures à 14.1.0.4 | ||
| Siemens | N/A | SIMOTION D455-2 DP/PN (6AU1455-2AD00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | SIMOTION D410-2 DP/PN (6AU1410-2AD00-0AA0) versions antérieures à 5.5 SP1 | ||
| Siemens | N/A | Teamcenter Visualization versions 14.1.x antérieures à 14.1.0.8 | ||
| Siemens | N/A | CP-8031 MASTER MODULE (6MF2803-1AA00) versions antérieures à CPCI85 V05 | ||
| Siemens | N/A | Totally Integrated Automation Portal (TIA Portal) versions 14 à 18 | ||
| Siemens | N/A | SIMATIC PCS 7 toutes versions | ||
| Siemens | N/A | SIMOTION D425-2 DP/PN (6AU1425-2AD00-0AA0) versions antérieures à 5.5 SP1 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SINAMICS GL150 versions ant\u00e9rieures \u00e0 7.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 13.3.x ant\u00e9rieures \u00e0 13.3.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D425-2 DP (6AU1425-2AA00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8050 MASTER MODULE (6MF2805-0AA00) versions ant\u00e9rieures \u00e0 CPCI85 V05",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q200 family versions ant\u00e9rieures \u00e0 2.70",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC Software V15 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D445-2 DP/PN (6AU1445-2AD00-0AA1) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D410-2 DP (6AU1410-2AA00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC STEP 7 V5 versions ant\u00e9rieures \u00e0 5.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION C240 (6AU1240-1AA00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 TM MFP - Linux Kernel",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAUT Software ST7sc toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION P320-4 E (6AU1320-4DE65-3AF0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.0.x ant\u00e9rieures \u00e0 14.0.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION C240 PN (6AU1240-1AB00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET PC Software V14 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 V9.0 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 V9.1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 TM MFP - BIOS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D435-2 DP/PN (6AU1435-2AD00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS SL150 versions ant\u00e9rieures \u00e0 7.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINAMICS PERFECT HARMONY GH180 6SR5 versions ant\u00e9rieures \u00e0 7.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 13.2.x ant\u00e9rieures \u00e0 13.2.0.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D435-2 DP (6AU1435-2AA00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION P320-4 S (6AU1320-4DS66-3AG0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC versions ant\u00e9rieures \u00e0 8.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.2.x ant\u00e9rieures \u00e0 14.2.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "les contr\u00f4lleurs Desigo PX, se r\u00e9f\u00e9rer au bulletin ssa-824231 de l\u0027\u00e9diteur pour la liste compl\u00e8te des versions affect\u00e9es",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D445-2 DP/PN (6AU1445-2AD00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PM toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2023 versions ant\u00e9rieures \u00e0 223.0 Update 5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 14.1.0.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D455-2 DP/PN (6AU1455-2AD00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D410-2 DP/PN (6AU1410-2AD00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions 14.1.x ant\u00e9rieures \u00e0 14.1.0.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "CP-8031 MASTER MODULE (6MF2803-1AA00) versions ant\u00e9rieures \u00e0 CPCI85 V05",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Totally Integrated Automation Portal (TIA Portal) versions 14 \u00e0 18",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTION D425-2 DP/PN (6AU1425-2AD00-0AA0) versions ant\u00e9rieures \u00e0 5.5 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2019-25013",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-25013"
},
{
"name": "CVE-2022-1343",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1343"
},
{
"name": "CVE-2021-42384",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42384"
},
{
"name": "CVE-2022-35252",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35252"
},
{
"name": "CVE-2022-1473",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1473"
},
{
"name": "CVE-2021-42378",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42378"
},
{
"name": "CVE-2022-39190",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39190"
},
{
"name": "CVE-2022-42720",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42720"
},
{
"name": "CVE-2021-42382",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42382"
},
{
"name": "CVE-2022-47520",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47520"
},
{
"name": "CVE-2021-38604",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-38604"
},
{
"name": "CVE-2022-21233",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21233"
},
{
"name": "CVE-2021-42376",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42376"
},
{
"name": "CVE-2022-3633",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3633"
},
{
"name": "CVE-2021-28831",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-28831"
},
{
"name": "CVE-2023-23454",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23454"
},
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2020-29562",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-29562"
},
{
"name": "CVE-2022-20421",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-20421"
},
{
"name": "CVE-2022-32208",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32208"
},
{
"name": "CVE-2018-4834",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-4834"
},
{
"name": "CVE-2022-32296",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32296"
},
{
"name": "CVE-2022-47929",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47929"
},
{
"name": "CVE-2022-3628",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3628"
},
{
"name": "CVE-2021-42373",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42373"
},
{
"name": "CVE-2022-1292",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1292"
},
{
"name": "CVE-2021-42377",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42377"
},
{
"name": "CVE-2022-42329",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42329"
},
{
"name": "CVE-2021-3998",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3998"
},
{
"name": "CVE-2023-23455",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23455"
},
{
"name": "CVE-2020-1752",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-1752"
},
{
"name": "CVE-2022-42703",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42703"
},
{
"name": "CVE-2022-47518",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47518"
},
{
"name": "CVE-2023-31238",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-31238"
},
{
"name": "CVE-2022-32207",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32207"
},
{
"name": "CVE-2023-0215",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0215"
},
{
"name": "CVE-2023-0286",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0286"
},
{
"name": "CVE-2021-42386",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42386"
},
{
"name": "CVE-2022-42895",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42895"
},
{
"name": "CVE-2023-33919",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33919"
},
{
"name": "CVE-2022-43750",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43750"
},
{
"name": "CVE-2022-21166",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21166"
},
{
"name": "CVE-2022-3435",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3435"
},
{
"name": "CVE-2022-3169",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3169"
},
{
"name": "CVE-2022-2068",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2068"
},
{
"name": "CVE-2021-42380",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42380"
},
{
"name": "CVE-2023-33920",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33920"
},
{
"name": "CVE-2023-0466",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0466"
},
{
"name": "CVE-2023-0465",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0465"
},
{
"name": "CVE-2022-4662",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4662"
},
{
"name": "CVE-2021-42374",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42374"
},
{
"name": "CVE-2023-33124",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33124"
},
{
"name": "CVE-2022-43545",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43545"
},
{
"name": "CVE-2022-3564",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3564"
},
{
"name": "CVE-2022-3534",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3534"
},
{
"name": "CVE-2022-36280",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36280"
},
{
"name": "CVE-2022-4129",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4129"
},
{
"name": "CVE-2022-41218",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41218"
},
{
"name": "CVE-2023-26495",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26495"
},
{
"name": "CVE-2022-34918",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-34918"
},
{
"name": "CVE-2022-20572",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-20572"
},
{
"name": "CVE-2022-41849",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41849"
},
{
"name": "CVE-2022-42432",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42432"
},
{
"name": "CVE-2022-42896",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42896"
},
{
"name": "CVE-2023-0179",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0179"
},
{
"name": "CVE-2022-47946",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47946"
},
{
"name": "CVE-2021-33655",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33655"
},
{
"name": "CVE-2022-2602",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2602"
},
{
"name": "CVE-2022-1462",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1462"
},
{
"name": "CVE-2023-25910",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25910"
},
{
"name": "CVE-2023-33921",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33921"
},
{
"name": "CVE-2022-4095",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4095"
},
{
"name": "CVE-2022-2585",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2585"
},
{
"name": "CVE-2023-0464",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0464"
},
{
"name": "CVE-2022-21125",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21125"
},
{
"name": "CVE-2022-2078",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2078"
},
{
"name": "CVE-2022-1184",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1184"
},
{
"name": "CVE-2022-41222",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41222"
},
{
"name": "CVE-2022-2663",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2663"
},
{
"name": "CVE-2022-2586",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2586"
},
{
"name": "CVE-2022-28391",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28391"
},
{
"name": "CVE-2023-26607",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-26607"
},
{
"name": "CVE-2022-3649",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3649"
},
{
"name": "CVE-2022-3545",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3545"
},
{
"name": "CVE-2020-10029",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10029"
},
{
"name": "CVE-2022-42719",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42719"
},
{
"name": "CVE-2018-25032",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-25032"
},
{
"name": "CVE-2021-42379",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42379"
},
{
"name": "CVE-2021-20269",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-20269"
},
{
"name": "CVE-2021-3999",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3999"
},
{
"name": "CVE-2021-3759",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3759"
},
{
"name": "CVE-2023-23559",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23559"
},
{
"name": "CVE-2022-3524",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3524"
},
{
"name": "CVE-2022-32250",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32250"
},
{
"name": "CVE-2022-2274",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2274"
},
{
"name": "CVE-2018-13405",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-13405"
},
{
"name": "CVE-2022-39188",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39188"
},
{
"name": "CVE-2021-42381",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42381"
},
{
"name": "CVE-2022-21505",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21505"
},
{
"name": "CVE-2022-36123",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36123"
},
{
"name": "CVE-2022-3586",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3586"
},
{
"name": "CVE-2021-4037",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-4037"
},
{
"name": "CVE-2022-41850",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41850"
},
{
"name": "CVE-2022-2978",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2978"
},
{
"name": "CVE-2022-3646",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3646"
},
{
"name": "CVE-2022-3625",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3625"
},
{
"name": "CVE-2022-42328",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42328"
},
{
"name": "CVE-2022-3565",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3565"
},
{
"name": "CVE-2023-33122",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33122"
},
{
"name": "CVE-2022-42721",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42721"
},
{
"name": "CVE-2022-4378",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4378"
},
{
"name": "CVE-2022-0547",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0547"
},
{
"name": "CVE-2022-21123",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21123"
},
{
"name": "CVE-2022-43398",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43398"
},
{
"name": "CVE-2022-1012",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1012"
},
{
"name": "CVE-2022-3115",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3115"
},
{
"name": "CVE-2021-42383",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42383"
},
{
"name": "CVE-2023-1095",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1095"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2022-0171",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-0171"
},
{
"name": "CVE-2022-26373",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-26373"
},
{
"name": "CVE-2022-2905",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2905"
},
{
"name": "CVE-2022-20422",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-20422"
},
{
"name": "CVE-2023-0394",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0394"
},
{
"name": "CVE-2022-32205",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32205"
},
{
"name": "CVE-2022-3594",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3594"
},
{
"name": "CVE-2022-36946",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36946"
},
{
"name": "CVE-2022-3303",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3303"
},
{
"name": "CVE-2016-10228",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-10228"
},
{
"name": "CVE-2021-42385",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42385"
},
{
"name": "CVE-2022-23308",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23308"
},
{
"name": "CVE-2022-1679",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1679"
},
{
"name": "CVE-2022-36879",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-36879"
},
{
"name": "CVE-2022-23218",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23218"
},
{
"name": "CVE-2023-27465",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27465"
},
{
"name": "CVE-2022-3629",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3629"
},
{
"name": "CVE-2023-33121",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33121"
},
{
"name": "CVE-2022-2959",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2959"
},
{
"name": "CVE-2023-28829",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28829"
},
{
"name": "CVE-2022-2588",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2588"
},
{
"name": "CVE-2022-2097",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2097"
},
{
"name": "CVE-2022-32206",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-32206"
},
{
"name": "CVE-2023-1077",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1077"
},
{
"name": "CVE-2021-35942",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-35942"
},
{
"name": "CVE-2023-1073",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1073"
},
{
"name": "CVE-2023-30757",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30757"
},
{
"name": "CVE-2021-33574",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-33574"
},
{
"name": "CVE-2022-42722",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-42722"
},
{
"name": "CVE-2021-3326",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-3326"
},
{
"name": "CVE-2022-20566",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-20566"
},
{
"name": "CVE-2022-2327",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2327"
},
{
"name": "CVE-2022-1199",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1199"
},
{
"name": "CVE-2022-3621",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3621"
},
{
"name": "CVE-2022-1434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1434"
},
{
"name": "CVE-2022-3606",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3606"
},
{
"name": "CVE-2022-1852",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1852"
},
{
"name": "CVE-2021-27645",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27645"
},
{
"name": "CVE-2022-40768",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40768"
},
{
"name": "CVE-2022-4139",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4139"
},
{
"name": "CVE-2022-3521",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3521"
},
{
"name": "CVE-2022-3104",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3104"
},
{
"name": "CVE-2021-42375",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42375"
},
{
"name": "CVE-2022-2503",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2503"
},
{
"name": "CVE-2022-3028",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3028"
},
{
"name": "CVE-2023-0590",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0590"
},
{
"name": "CVE-2023-30897",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30897"
},
{
"name": "CVE-2022-40307",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-40307"
},
{
"name": "CVE-2020-27618",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27618"
},
{
"name": "CVE-2022-23219",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23219"
},
{
"name": "CVE-2022-30065",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30065"
},
{
"name": "CVE-2022-41674",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41674"
},
{
"name": "CVE-2022-1882",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1882"
},
{
"name": "CVE-2022-3635",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-3635"
},
{
"name": "CVE-2022-43439",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43439"
},
{
"name": "CVE-2023-33123",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33123"
},
{
"name": "CVE-2023-30901",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-30901"
},
{
"name": "CVE-2022-43546",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43546"
},
{
"name": "CVE-2022-2153",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-2153"
}
],
"initial_release_date": "2023-06-13T00:00:00",
"last_revision_date": "2023-06-14T00:00:00",
"links": [],
"reference": "CERTFR-2023-AVI-0453",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-06-13T00:00:00.000000"
},
{
"description": "Modification de la date du bulletin de s\u00e9curit\u00e9 ssa-824231.",
"revision_date": "2023-06-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-975766 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-975766.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-042050 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-042050.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-731916 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-731916.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-914026 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-914026.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-794697 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-794697.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-538795 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-538795.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-831302 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-831302.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-482956 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-482956.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-508677 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-508677.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-968170 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-968170.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-824231 du 24 janvier 2018",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-824231.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-942865 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-942865.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-887249 du 13 juin 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-887249.html"
}
]
}
CERTFR-2022-AVI-1001
Vulnerability from certfr_avis - Published: 2022-11-08 - Updated: 2022-11-08
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions antérieures à V2.50 | ||
| Siemens | N/A | SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SINUMERIK MC toutes versions | ||
| Siemens | N/A | SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions | ||
| Siemens | N/A | SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SINUMERIK ONE toutes versions | ||
| Siemens | N/A | SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | Parasolid versions antérieures à V34.0.254 | ||
| Siemens | N/A | SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions antérieures à V2.50 | ||
| Siemens | N/A | Teamcenter Visualization V14.0 versions antérieures à V14.0.0.3 | ||
| Siemens | N/A | SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0) versions antérieures à V3.3.19 | ||
| Siemens | N/A | Teamcenter Visualization V14.1 versions antérieures à V14.1.0.4 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC Drive Controller family toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | Teamcenter Visualization V13.3 versions antérieures à V13.3.0.7 | ||
| Siemens | N/A | Parasolid versions antérieures à V35.0.184 | ||
| Siemens | N/A | JT2Go versions antérieures à V14.1.0.4 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-PLCSIM Advanced toutes versions | ||
| Siemens | N/A | QMS Automotive toutes versions | ||
| Siemens | N/A | SIMATIC PC Station versions antérieures à V2.1 | ||
| Siemens | N/A | SIMATIC S7-1200 CPU family (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | Parasolid versions antérieures à V34.1.244 | ||
| Siemens | N/A | SIMATIC WinCC Runtime Advanced toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0) versions antérieures à V3.3.19 | ||
| Siemens | N/A | RUGGEDCOM ROS toutes versions | ||
| Siemens | N/A | SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions | ||
| Siemens | N/A | SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0) versions antérieures à V3.2.19 | ||
| Siemens | N/A | SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | SIMATIC S7-1500 Software Controller toutes versions | ||
| Siemens | N/A | SINEC NMS versions antérieures à 1.0.3 | ||
| Siemens | N/A | SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0) versions antérieures à V3.2.19 |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions ant\u00e9rieures \u00e0 V2.50",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 317F-2 PN/DP (6AG1317-2FK14-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 315F-2 PN/DP (6AG1315-2FJ14-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200pro IM154-8F PN/DP CPU (6ES7154-8FB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 315-2 PN/DP (6ES7315-2EH14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK MC toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (ROW) (6GK5750-2HX01-1AA0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 317-2 PN/DP (6AG1317-2EK14-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200pro IM154-8FX PN/DP CPU (6ES7154-8FX00-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK ONE toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200S IM151-8 PN/DP CPU (6ES7151-8AB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions ant\u00e9rieures \u00e0 V34.0.254",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200pro IM154-8 PN/DP CPU (6ES7154-8AB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200S IM151-8 PN/DP CPU (6AG1151-8AB01-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions ant\u00e9rieures \u00e0 V2.50",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization V14.0 versions ant\u00e9rieures \u00e0 V14.0.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 314C-2 PN/DP (6AG1314-6EH04-7AB0) versions ant\u00e9rieures \u00e0 V3.3.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization V14.1 versions ant\u00e9rieures \u00e0 V14.1.0.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 315F-2 PN/DP (6ES7315-2FJ14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (JP) (6GK5750-2HX01-1AD0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 317-2 PN/DP (6ES7317-2EK14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS ET 200S IM151-8F PN/DP CPU (6AG1151-8FB01-2AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS S7-300 CPU 315-2 PN/DP (6AG1315-2EH14-7AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 315T-3 PN/DP (6ES7315-7TJ10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Drive Controller family toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 319-3 PN/DP (6ES7318-3EL01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization V13.3 versions ant\u00e9rieures \u00e0 V13.3.0.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions ant\u00e9rieures \u00e0 V35.0.184",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 V14.1.0.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 319F-3 PN/DP (6ES7318-3FL01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "QMS Automotive toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PC Station versions ant\u00e9rieures \u00e0 V2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1200 CPU family (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid versions ant\u00e9rieures \u00e0 V34.1.244",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC Runtime Advanced toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 CPU family (incl. related ET200 CPUs and SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 317F-2 PN/DP (6ES7317-2FK14-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP V7 CPU family (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 314C-2 PN/DP (6ES7314-6EH04-0AB0) versions ant\u00e9rieures \u00e0 V3.3.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM ROS toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ET 200S IM151-8F PN/DP CPU (6ES7151-8FB01-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D (USA) (6GK5750-2HX01-1AB0) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 317T-3 PN/DP (6ES7317-7TK10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-400 PN/DP V6 CPU family (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-1500 Software Controller toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC NMS versions ant\u00e9rieures \u00e0 1.0.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-300 CPU 317TF-3 PN/DP (6ES7317-7UL10-0AB0) versions ant\u00e9rieures \u00e0 V3.2.19",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2022-37889",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37889"
},
{
"name": "CVE-2022-39157",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39157"
},
{
"name": "CVE-2022-41664",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41664"
},
{
"name": "CVE-2022-41662",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41662"
},
{
"name": "CVE-2022-37891",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37891"
},
{
"name": "CVE-2022-41663",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41663"
},
{
"name": "CVE-2022-37888",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37888"
},
{
"name": "CVE-2002-20001",
"url": "https://www.cve.org/CVERecord?id=CVE-2002-20001"
},
{
"name": "CVE-2022-43397",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43397"
},
{
"name": "CVE-2022-43545",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43545"
},
{
"name": "CVE-2022-37893",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37893"
},
{
"name": "CVE-2022-37892",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37892"
},
{
"name": "CVE-2022-39158",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39158"
},
{
"name": "CVE-2022-37890",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37890"
},
{
"name": "CVE-2022-43958",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43958"
},
{
"name": "CVE-2022-37895",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37895"
},
{
"name": "CVE-2022-37896",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37896"
},
{
"name": "CVE-2022-41661",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41661"
},
{
"name": "CVE-2022-43398",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43398"
},
{
"name": "CVE-2022-39136",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39136"
},
{
"name": "CVE-2022-30694",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30694"
},
{
"name": "CVE-2021-42550",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42550"
},
{
"name": "CVE-2022-37886",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37886"
},
{
"name": "CVE-2022-38465",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-38465"
},
{
"name": "CVE-2022-37885",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37885"
},
{
"name": "CVE-2022-37887",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37887"
},
{
"name": "CVE-2022-37894",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37894"
},
{
"name": "CVE-2022-43439",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43439"
},
{
"name": "CVE-2022-41660",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41660"
},
{
"name": "CVE-2022-43546",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43546"
}
],
"initial_release_date": "2022-11-08T00:00:00",
"last_revision_date": "2022-11-08T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 478960 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-478960.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 568428 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-568428.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 853037 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-853037.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 120378 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-120378.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 587547 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-587547.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 506569 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-506569.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 570294 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-570294.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 787941 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-787941.html"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 371761 du 8 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-371761.html"
}
],
"reference": "CERTFR-2022-AVI-1001",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2022-11-08T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Injection de requ\u00eates ill\u00e9gitimes par rebond (CSRF)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens 853037 du 08 novembre 2022",
"url": null
}
]
}
FKIE_CVE-2022-43398
Vulnerability from fkie_nvd - Published: 2022-11-08 11:15 - Updated: 2024-11-21 07:268.8 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf | Mitigation, Patch, Vendor Advisory | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf | Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | 7kg9501-0aa01-2aa1_firmware | * | |
| siemens | 7kg9501-0aa01-2aa1 | - | |
| siemens | 7kg9501-0aa31-2aa1_firmware | * | |
| siemens | 7kg9501-0aa31-2aa1 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:7kg9501-0aa01-2aa1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "821380FC-8F3A-4437-94FF-FB95D9F187D0",
"versionEndExcluding": "2.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:7kg9501-0aa01-2aa1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "275E9296-AACA-4F3B-B8FA-D52A59E729DE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:7kg9501-0aa31-2aa1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AEE155DF-AB9B-4A85-A845-AF1B51B05833",
"versionEndExcluding": "2.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:7kg9501-0aa31-2aa1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC260D4F-53BD-433C-AE8F-FA2FA47BC921",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user\u0027s account through the activated session."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la familia POWER METER SICAM Q200 (Todas las versiones \u0026lt; V2.70). Los dispositivos afectados no renuevan la cookie de sesi\u00f3n despu\u00e9s de iniciar/cerrar sesi\u00f3n y tambi\u00e9n aceptan cookies de sesi\u00f3n definidas por el usuario. Un atacante podr\u00eda sobrescribir la cookie de sesi\u00f3n almacenada de un usuario. Despu\u00e9s de que la v\u00edctima inicia sesi\u00f3n, el atacante obtiene acceso a la cuenta del usuario a trav\u00e9s de la sesi\u00f3n activada."
}
],
"id": "CVE-2022-43398",
"lastModified": "2024-11-21T07:26:24.183",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-11-08T11:15:11.940",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-384"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-384"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GSD-2022-43398
Vulnerability from gsd - Updated: 2023-12-13 01:19{
"GSD": {
"alias": "CVE-2022-43398",
"id": "GSD-2022-43398"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2022-43398"
],
"details": "A vulnerability has been identified in POWER METER SICAM Q200 family (All versions \u003c V2.70). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user\u0027s account through the activated session.",
"id": "GSD-2022-43398",
"modified": "2023-12-13T01:19:31.514115Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2022-43398",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "POWER METER SICAM Q100",
"version": {
"version_data": [
{
"version_affected": "=",
"version_value": "All versions \u003c V2.50"
},
{
"version_affected": "=",
"version_value": "All versions \u003c V2.50"
},
{
"version_affected": "=",
"version_value": "All versions \u003c V2.50"
},
{
"version_affected": "=",
"version_value": "All versions \u003c V2.50"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user\u0027s account through the activated session."
}
]
},
"impact": {
"cvss": [
{
"baseScore": 7.5,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"cweId": "CWE-384",
"lang": "eng",
"value": "CWE-384: Session Fixation"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
}
]
}
},
"nvd.nist.gov": {
"cve": {
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:7kg9501-0aa01-2aa1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "821380FC-8F3A-4437-94FF-FB95D9F187D0",
"versionEndExcluding": "2.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:7kg9501-0aa01-2aa1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "275E9296-AACA-4F3B-B8FA-D52A59E729DE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:7kg9501-0aa31-2aa1_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AEE155DF-AB9B-4A85-A845-AF1B51B05833",
"versionEndExcluding": "2.50",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:7kg9501-0aa31-2aa1:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC260D4F-53BD-433C-AE8F-FA2FA47BC921",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user\u0027s account through the activated session."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en la familia POWER METER SICAM Q200 (Todas las versiones \u0026lt; V2.70). Los dispositivos afectados no renuevan la cookie de sesi\u00f3n despu\u00e9s de iniciar/cerrar sesi\u00f3n y tambi\u00e9n aceptan cookies de sesi\u00f3n definidas por el usuario. Un atacante podr\u00eda sobrescribir la cookie de sesi\u00f3n almacenada de un usuario. Despu\u00e9s de que la v\u00edctima inicia sesi\u00f3n, el atacante obtiene acceso a la cuenta del usuario a trav\u00e9s de la sesi\u00f3n activada."
}
],
"id": "CVE-2022-43398",
"lastModified": "2024-01-09T10:15:14.363",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.6,
"impactScore": 5.9,
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
},
"published": "2022-11-08T11:15:11.940",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-384"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-384"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
}
]
}
}
}
}
CNVD-2022-75541
Vulnerability from cnvd - Published: 2022-11-09厂商已发布了漏洞修复程序,请及时关注更新: https://cert-portal.siemens.com/productcert/html/ssa-570294.html
| Name | ['Siemens POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) <2.50', 'Siemens POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) <2.50'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2022-43398"
}
},
"description": "POWER METER SICAM Q100\u662f\u4e00\u79cd\u591a\u529f\u80fd\u8bbe\u5907\uff0c\u7528\u4e8e\u68c0\u6d4b\u3001\u62a5\u544a\u548c\u5206\u6790\u6d4b\u91cf\u503c\u548c\u4e8b\u4ef6\u3002\n\nSiemens POWER METER SICAM Q100\u5b58\u5728\u4f1a\u8bdd\u56fa\u5b9a\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u901a\u8fc7\u6fc0\u6d3b\u7684\u4f1a\u8bdd\u8bbf\u95ee\u7528\u6237\u7684\u5e10\u6237\u3002",
"formalWay": "\u5382\u5546\u5df2\u53d1\u5e03\u4e86\u6f0f\u6d1e\u4fee\u590d\u7a0b\u5e8f\uff0c\u8bf7\u53ca\u65f6\u5173\u6ce8\u66f4\u65b0\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-570294.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2022-75541",
"openTime": "2022-11-09",
"patchDescription": "POWER METER SICAM Q100\u662f\u4e00\u79cd\u591a\u529f\u80fd\u8bbe\u5907\uff0c\u7528\u4e8e\u68c0\u6d4b\u3001\u62a5\u544a\u548c\u5206\u6790\u6d4b\u91cf\u503c\u548c\u4e8b\u4ef6\u3002\r\n\r\nSiemens POWER METER SICAM Q100\u5b58\u5728\u4f1a\u8bdd\u56fa\u5b9a\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u901a\u8fc7\u6fc0\u6d3b\u7684\u4f1a\u8bdd\u8bbf\u95ee\u7528\u6237\u7684\u5e10\u6237\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens POWER METER SICAM Q100\u4f1a\u8bdd\u56fa\u5b9a\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) \u003c2.50",
"Siemens POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) \u003c2.50"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-570294.html",
"serverity": "\u9ad8",
"submitTime": "2022-11-09",
"title": "Siemens POWER METER SICAM Q100\u4f1a\u8bdd\u56fa\u5b9a\u6f0f\u6d1e"
}
GHSA-FPH2-95MP-M2FQ
Vulnerability from github – Published: 2022-11-08 12:00 – Updated: 2022-11-09 19:02A vulnerability has been identified in POWER METER SICAM Q100 (All versions < V2.50), POWER METER SICAM Q100 (All versions < V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user's account through the activated session.
{
"affected": [],
"aliases": [
"CVE-2022-43398"
],
"database_specific": {
"cwe_ids": [
"CWE-384"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2022-11-08T11:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in POWER METER SICAM Q100 (All versions \u003c V2.50), POWER METER SICAM Q100 (All versions \u003c V2.50). Affected devices do not renew the session cookie after login/logout and also accept user defined session cookies. An attacker could overwrite the stored session cookie of a user. After the victim logged in, the attacker is given access to the user\u0027s account through the activated session.",
"id": "GHSA-fph2-95mp-m2fq",
"modified": "2022-11-09T19:02:23Z",
"published": "2022-11-08T12:00:17Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2022-43398"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-570294.pdf"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-887249.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.