CVE-2023-33217 (GCVE-0-2023-33217)
Vulnerability from cvelistv5 – Published: 2023-12-15 10:45 – Updated: 2024-08-02 15:39
VLAI?
Title
Missing integrity check on upgrade package
Summary
By abusing a design flaw in the firmware upgrade mechanism of the impacted terminal it's possible to cause a permanent
denial of service for the terminal. the only way to recover the terminal is by sending back the terminal to the manufacturer
Severity ?
7.5 (High)
4.9 (Medium)
CWE
- CWE-20 - Improper Input Validation
Assigner
References
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| IDEMIA | SIGMA Lite & Lite + |
Affected:
0 , < 4.15.5
(custom)
|
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T15:39:35.734Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "SIGMA Lite \u0026 Lite +",
"vendor": "IDEMIA",
"versions": [
{
"lessThan": "4.15.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SIGMA Wide",
"vendor": "IDEMIA",
"versions": [
{
"lessThan": "4.15.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "SIGMA Extreme",
"vendor": "IDEMIA",
"versions": [
{
"lessThan": "4.15.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MorphoWave Compact/XP",
"vendor": "IDEMIA",
"versions": [
{
"lessThan": "2.12.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VisionPass",
"vendor": "IDEMIA",
"versions": [
{
"lessThan": "2.12.2",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "MorphoWave SP",
"vendor": "IDEMIA",
"versions": [
{
"lessThan": "1.2.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\n\nBy abusing a design flaw in the firmware upgrade mechanism of the impacted terminal it\u0027s possible to cause a permanent \ndenial of service for the terminal. the only way to recover the terminal is by sending back the terminal to the manufacturer"
}
],
"value": "\nBy abusing a design flaw in the firmware upgrade mechanism of the impacted terminal it\u0027s possible to cause a permanent \ndenial of service for the terminal. the only way to recover the terminal is by sending back the terminal to the manufacturer"
}
],
"impacts": [
{
"capecId": "CAPEC-153",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-153 Input Data Manipulation"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 4.9,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "if you have kept the default Enforced Security mode or enabled the mTLS to identify the origin of the command issued to the termina"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-20",
"description": "CWE-20 Improper Input Validation",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-12-15T10:45:30.637Z",
"orgId": "a87f365f-9d39-4848-9b3a-58c7cae69cab",
"shortName": "IDEMIA"
},
"references": [
{
"url": "https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "Missing integrity check on upgrade package",
"x_generator": {
"engine": "Vulnogram 0.1.0-dev"
}
}
},
"cveMetadata": {
"assignerOrgId": "a87f365f-9d39-4848-9b3a-58c7cae69cab",
"assignerShortName": "IDEMIA",
"cveId": "CVE-2023-33217",
"datePublished": "2023-12-15T10:45:30.637Z",
"dateReserved": "2023-05-18T14:32:49.222Z",
"dateUpdated": "2024-08-02T15:39:35.734Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…