CVE-2017-17407 (GCVE-0-2017-17407)
Vulnerability from cvelistv5 – Published: 2018-01-23 01:00 – Updated: 2024-08-05 20:51
VLAI?
Summary
This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of NetGain Systems Enterprise Manager v7.2.699 build 1001. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of the content parameter provided to the script_test.jsp endpoint. A crafted content request parameter can trigger execution of a system call composed from a user-supplied string. An attacker can leverage this vulnerability to execute code under the context of the web service. Was ZDI-CAN-5080.
Severity ?
No CVSS data available.
CWE
- CWE-78 - Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| NetGain Systems | NetGain Systems Enterprise Manager |
Affected:
v7.2.699 build 1001
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T20:51:30.858Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://zerodayinitiative.com/advisories/ZDI-17-954"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "NetGain Systems Enterprise Manager",
"vendor": "NetGain Systems",
"versions": [
{
"status": "affected",
"version": "v7.2.699 build 1001"
}
]
}
],
"datePublic": "2017-12-13T00:00:00.000Z",
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of NetGain Systems Enterprise Manager v7.2.699 build 1001. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of the content parameter provided to the script_test.jsp endpoint. A crafted content request parameter can trigger execution of a system call composed from a user-supplied string. An attacker can leverage this vulnerability to execute code under the context of the web service. Was ZDI-CAN-5080."
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "CWE-78-Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2018-01-23T00:57:01.000Z",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://zerodayinitiative.com/advisories/ZDI-17-954"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2017-17407",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "NetGain Systems Enterprise Manager",
"version": {
"version_data": [
{
"version_value": "v7.2.699 build 1001"
}
]
}
}
]
},
"vendor_name": "NetGain Systems"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to execute arbitrary code on vulnerable installations of NetGain Systems Enterprise Manager v7.2.699 build 1001. Authentication is not required to exploit this vulnerability. The specific flaw exists within the handling of the content parameter provided to the script_test.jsp endpoint. A crafted content request parameter can trigger execution of a system call composed from a user-supplied string. An attacker can leverage this vulnerability to execute code under the context of the web service. Was ZDI-CAN-5080."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-78-Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://zerodayinitiative.com/advisories/ZDI-17-954",
"refsource": "MISC",
"url": "https://zerodayinitiative.com/advisories/ZDI-17-954"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2017-17407",
"datePublished": "2018-01-23T01:00:00.000Z",
"dateReserved": "2017-12-05T00:00:00.000Z",
"dateUpdated": "2024-08-05T20:51:30.858Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…