Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2018-7855 (GCVE-0-2018-7855)
Vulnerability from cvelistv5 – Published: 2019-05-22 20:03 – Updated: 2024-08-05 06:37- Multiple Vulnerabilities
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | ||
|---|---|---|---|---|
| n/a | Modicon M580 Modicon M340 Modicon Quantum Modicon Premium |
Affected:
Modicon M580 Modicon M340 Modicon Quantum Modicon Premium
|
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-05T06:37:59.652Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus"
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "Multiple Vulnerabilities",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2019-06-10T17:06:05.000Z",
"orgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"shortName": "schneider"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7855",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "076d1eb6-cfab-4401-b34d-6dfc2a413bdb",
"assignerShortName": "schneider",
"cveId": "CVE-2018-7855",
"datePublished": "2019-05-22T20:03:17.000Z",
"dateReserved": "2018-03-08T00:00:00.000Z",
"dateUpdated": "2024-08-05T06:37:59.652Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
GSD-2018-7855
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2018-7855",
"description": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus",
"id": "GSD-2018-7855"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2018-7855"
],
"details": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus",
"id": "GSD-2018-7855",
"modified": "2023-12-13T01:22:32.994447Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7855",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium",
"version": {
"version_data": [
{
"version_value": "Modicon M580 Modicon M340 Modicon Quantum Modicon Premium"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "Multiple Vulnerabilities"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766",
"refsource": "MISC",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_premium_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_quantum_firmware:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "3.10",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2.90",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cybersecurity@schneider-electric.com",
"ID": "CVE-2018-7855"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-754"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"refsource": "MISC",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767",
"refsource": "MISC",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"name": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766",
"refsource": "MISC",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-02-03T14:23Z",
"publishedDate": "2019-05-22T21:29Z"
}
}
}
GHSA-WP34-JMP7-4Q9F
Vulnerability from github – Published: 2022-05-24 16:46 – Updated: 2022-05-24 16:46A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus
{
"affected": [],
"aliases": [
"CVE-2018-7855"
],
"database_specific": {
"cwe_ids": [
"CWE-754"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2019-05-22T21:29:00Z",
"severity": "HIGH"
},
"details": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus",
"id": "GHSA-wp34-jmp7-4q9f",
"modified": "2022-05-24T16:46:14Z",
"published": "2022-05-24T16:46:14Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2018-7855"
},
{
"type": "WEB",
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11"
},
{
"type": "WEB",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
},
{
"type": "WEB",
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
}
],
"schema_version": "1.4.0",
"severity": []
}
CERTFR-2019-AVI-384
Vulnerability from certfr_avis - Published: 2019-08-13 - Updated: 2019-08-14
De multiples vulnérabilités ont été découvertes dans les produits Schneider Electric. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | EcoStruxure Machine Expert HVAC (anciennement SoMachine HVAC) versions antérieures à 1.1.0 | ||
| Schneider Electric | N/A | Wiser for KNX (anciennement homeLYnk) versions antérieures à 2.4.0 | ||
| Schneider Electric | N/A | Modicon Premium | ||
| Schneider Electric | N/A | TelevisGO versions produites avant le 15 juillet 2019 et utilisant une version de UltraVNC, 1.0.9.6.1 et antérieure, sans le correctif de sécurité TelevisGo_HotFix_20190715.exe | ||
| Schneider Electric | N/A | Magelis HMIGTO series | ||
| Schneider Electric | N/A | Magelis XBTGH series | ||
| Schneider Electric | N/A | Magelis HMIGTUX series | ||
| Schneider Electric | N/A | Magelis XBTGC series | ||
| Schneider Electric | N/A | Modicon M580 versions antérieures à V2.90 | ||
| Schneider Electric | N/A | Magelis HMIGTU series | ||
| Schneider Electric | N/A | BMXNOR0200H Ethernet / Serial RTU module | ||
| Schneider Electric | N/A | Magelis HMISTO series | ||
| Schneider Electric | N/A | Magelis HMISCU series | ||
| Schneider Electric | N/A | Magelis HMIGXO series | ||
| Schneider Electric | Modicon M340 | Modicon M340 versions antérieures à V3.10 | ||
| Schneider Electric | N/A | Schneider Electric Software Update (SESU) SUT Service component versions antérieures à 2.3.1 | ||
| Schneider Electric | N/A | Magelis XBTGT series | ||
| Schneider Electric | N/A | Magelis HMIGXU series | ||
| Schneider Electric | N/A | Magelis HMISTU series | ||
| Schneider Electric | N/A | spaceLYnk versions antérieures à 2.4.0 | ||
| Schneider Electric | N/A | Modicon Quantum |
| Title | Publication Time | Tags | ||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "EcoStruxure Machine Expert HVAC (anciennement SoMachine HVAC) versions ant\u00e9rieures \u00e0 1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Wiser for KNX (anciennement homeLYnk) versions ant\u00e9rieures \u00e0 2.4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Premium",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "TelevisGO versions produites avant le 15 juillet 2019 et utilisant une version de UltraVNC, 1.0.9.6.1 et ant\u00e9rieure, sans le correctif de s\u00e9curit\u00e9 TelevisGo_HotFix_20190715.exe",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGH series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTUX series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGC series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M580 versions ant\u00e9rieures \u00e0 V2.90",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGTU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "BMXNOR0200H Ethernet / Serial RTU module",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISTO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISCU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGXO series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon M340 versions ant\u00e9rieures \u00e0 V3.10",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Software Update (SESU) SUT Service component versions ant\u00e9rieures \u00e0 2.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis XBTGT series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMIGXU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Magelis HMISTU series",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "spaceLYnk versions ant\u00e9rieures \u00e0 2.4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Modicon Quantum",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2018-15361",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15361"
},
{
"name": "CVE-2019-8262",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8262"
},
{
"name": "CVE-2019-8277",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8277"
},
{
"name": "CVE-2019-6828",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6828"
},
{
"name": "CVE-2019-8265",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8265"
},
{
"name": "CVE-2019-8269",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8269"
},
{
"name": "CVE-2019-8260",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8260"
},
{
"name": "CVE-2019-8263",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8263"
},
{
"name": "CVE-2019-6832",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6832"
},
{
"name": "CVE-2019-8261",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8261"
},
{
"name": "CVE-2019-8276",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8276"
},
{
"name": "CVE-2018-7846",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7846"
},
{
"name": "CVE-2019-8259",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8259"
},
{
"name": "CVE-2018-7842",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7842"
},
{
"name": "CVE-2018-7849",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7849"
},
{
"name": "CVE-2019-8271",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8271"
},
{
"name": "CVE-2019-6831",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6831"
},
{
"name": "CVE-2019-6813",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6813"
},
{
"name": "CVE-2019-6809",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6809"
},
{
"name": "CVE-2019-6829",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6829"
},
{
"name": "CVE-2018-7852",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7852"
},
{
"name": "CVE-2019-8267",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8267"
},
{
"name": "CVE-2019-6830",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6830"
},
{
"name": "CVE-2019-6810",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6810"
},
{
"name": "CVE-2018-7854",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7854"
},
{
"name": "CVE-2019-8280",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8280"
},
{
"name": "CVE-2018-7844",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7844"
},
{
"name": "CVE-2018-7847",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7847"
},
{
"name": "CVE-2018-7855",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7855"
},
{
"name": "CVE-2019-8275",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8275"
},
{
"name": "CVE-2019-8274",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8274"
},
{
"name": "CVE-2019-6808",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6808"
},
{
"name": "CVE-2019-6826",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6826"
},
{
"name": "CVE-2018-7850",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7850"
},
{
"name": "CVE-2018-7856",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7856"
},
{
"name": "CVE-2019-8266",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8266"
},
{
"name": "CVE-2019-8270",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8270"
},
{
"name": "CVE-2019-6834",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6834"
},
{
"name": "CVE-2019-68067",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-68067"
},
{
"name": "CVE-2018-7845",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7845"
},
{
"name": "CVE-2019-8258",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8258"
},
{
"name": "CVE-2018-7857",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7857"
},
{
"name": "CVE-2019-8264",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8264"
},
{
"name": "CVE-2019-6833",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-6833"
},
{
"name": "CVE-2019-8272",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8272"
},
{
"name": "CVE-2019-8268",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8268"
},
{
"name": "CVE-2019-68077",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-68077"
},
{
"name": "CVE-2019-8273",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-8273"
},
{
"name": "CVE-2018-7853",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7853"
},
{
"name": "CVE-2018-7843",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7843"
},
{
"name": "CVE-2018-7848",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7848"
}
],
"initial_release_date": "2019-08-13T00:00:00",
"last_revision_date": "2019-08-14T00:00:00",
"links": [],
"reference": "CERTFR-2019-AVI-384",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2019-08-13T00:00:00.000000"
},
{
"description": "Ajout du bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-04 du 13 ao\u00fbt 2019",
"revision_date": "2019-08-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSchneider Electric. Certaines d\u0027entre elles permettent \u00e0 un attaquant de\nprovoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de\nservice \u00e0 distance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider Electric",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-06 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-06-SESU_SUT_Service.pdf\u0026p_Doc_Ref=SEVD-2019-225-06"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-04 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-04_SoMachine_HVAC_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-04"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-01 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-01-Magelis_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-01"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-03 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-03-Modicon-Ethernet+-Serial-RTU-Module-Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-03"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-07 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-07-spaceLYnk-homeLYnk.pdf\u0026p_Doc_Ref=SEVD-2019-225-07"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-02 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-02-Modicon_M340_Controllers_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-02"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-134-11 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-134-11-V2-Modicon-Controllers.pdf\u0026p_Doc_Ref=SEVD-2019-134-11"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider Electric SEVD-2019-225-05 du 13 ao\u00fbt 2019",
"url": "https://download.schneider-electric.com/files?p_enDocType=Technical+leaflet\u0026p_File_Name=SEVD-2019-225-05-TelevisGO_Security_Notification.pdf\u0026p_Doc_Ref=SEVD-2019-225-05"
}
]
}
CERTFR-2024-AVI-0120
Vulnerability from certfr_avis - Published: 2024-02-13 - Updated: 2024-02-13
De multiples vulnérabilités ont été découvertes dans les produits Schneider. Certaines d'entre elles permettent à un attaquant de provoquer un déni de service à distance, une atteinte à la confidentialité des données et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Schneider Electric | N/A | Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) toutes versions | ||
| Schneider Electric | N/A | Schneider Electric EcoStruxure™ Control Expert versions antérieures à v16.0 | ||
| Schneider Electric | N/A | Schneider Electric EcoStruxure IT Gateway versions antérieures à 1.20.0 | ||
| Schneider Electric | N/A | Schneider Electric Modicon M540 microgiciel versions antérieures à v3.60 | ||
| Symfony | process | Schneider Electric EcoStruxure™ Process Expert versions antérieures à v2023 | ||
| Schneider Electric | N/A | Schneider Electric Modicon M580 microgiciel versions antérieures à v4.20 | ||
| Schneider Electric | N/A | Schneider Electric Harmony Control Relay RMNF22TB30 toutes versions | ||
| Schneider Electric | Modicon M340 | Schneider Electric Modicon M340 CPU (part numbers BMXP34*) versions antérieures à sv3.60 | ||
| Schneider Electric | N/A | Schneider Electric Harmony Timer Relay RENF22R2MMW toutes versions | ||
| Schneider Electric | N/A | Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) versions antérieures à sv4.20 |
| Title | Publication Time | Tags | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Schneider Electric Modicon M580 CPU Safety (part numbers BMEP58*S and BMEH58*S) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric EcoStruxure\u2122 Control Expert versions ant\u00e9rieures \u00e0 v16.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric EcoStruxure IT Gateway versions ant\u00e9rieures \u00e0 1.20.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Modicon M540 microgiciel versions ant\u00e9rieures \u00e0 v3.60",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric EcoStruxure\u2122 Process Expert versions ant\u00e9rieures \u00e0 v2023",
"product": {
"name": "process",
"vendor": {
"name": "Symfony",
"scada": false
}
}
},
{
"description": "Schneider Electric Modicon M580 microgiciel versions ant\u00e9rieures \u00e0 v4.20",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Harmony Control Relay RMNF22TB30 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Modicon M340 CPU (part numbers BMXP34*) versions ant\u00e9rieures \u00e0 sv3.60",
"product": {
"name": "Modicon M340",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Harmony Timer Relay RENF22R2MMW toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
},
{
"description": "Schneider Electric Modicon M580 CPU (part numbers BMEP* and BMEH*, excluding M580 CPU Safety) versions ant\u00e9rieures \u00e0 sv4.20",
"product": {
"name": "N/A",
"vendor": {
"name": "Schneider Electric",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-6408",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6408"
},
{
"name": "CVE-2023-27975",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-27975"
},
{
"name": "CVE-2018-7855",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-7855"
},
{
"name": "CVE-2024-0568",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-0568"
},
{
"name": "CVE-2023-6409",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-6409"
},
{
"name": "CVE-2024-0865",
"url": "https://www.cve.org/CVERecord?id=CVE-2024-0865"
}
],
"initial_release_date": "2024-02-13T00:00:00",
"last_revision_date": "2024-02-13T00:00:00",
"links": [],
"reference": "CERTFR-2024-AVI-0120",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2024-02-13T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits Schneider\u003c/span\u003e. Certaines d\u0027entre elles\npermettent \u00e0 un attaquant de provoquer un d\u00e9ni de service \u00e0 distance,\nune atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es et une atteinte \u00e0\nl\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Schneider",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2024-044-03 du 13 f\u00e9vrier 2024",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-03\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-03.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2024-044-01 du 13 f\u00e9vrier 2024",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-01\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-01.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2019-134-11 du 14 mai 2019",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2019-134-11\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2019-134-11_Modicon_Controllers_Security_Notification.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Schneider SEVD-2024-044-02 du 13 f\u00e9vrier 2024",
"url": "https://download.schneider-electric.com/files?p_Doc_Ref=SEVD-2024-044-02\u0026p_enDocType=Security+and+Safety+Notice\u0026p_File_Name=SEVD-2024-044-02.pdf"
}
]
}
FKIE_CVE-2018-7855
Vulnerability from fkie_nvd - Published: 2019-05-22 21:29 - Updated: 2024-11-21 04:12| URL | Tags | ||
|---|---|---|---|
| cybersecurity@se.com | https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/ | Mitigation, Vendor Advisory | |
| cybersecurity@se.com | https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766 | Exploit, Third Party Advisory | |
| cybersecurity@se.com | https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/ | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767 | Exploit, Third Party Advisory |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_premium_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "14A20823-667A-423E-BB4B-2530B3EF1AF7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_premium:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F00936E2-E6EF-4ABF-8666-7D83BE424F42",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_quantum_firmware:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1B52EEB1-70EF-4D6E-82A7-73576462F7FB",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_quantum:-:*:*:*:*:*:*:*",
"matchCriteriaId": "A9B7CEF7-B9BA-4923-808F-DA2931569EBB",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m340_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3FD2397C-67A1-4AFD-BC42-6ECC3BD88C24",
"versionEndExcluding": "3.10",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m340:-:*:*:*:*:*:*:*",
"matchCriteriaId": "138681A2-0146-492B-8E10-06849FC27C6E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:schneider-electric:modicon_m580_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B9C5B0D1-D3A4-468A-807E-6BB3F98CC116",
"versionEndExcluding": "2.90",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:schneider-electric:modicon_m580:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E876C738-ABF6-4864-98A6-1E06E96A0DF4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-248 Uncaught Exception vulnerability exists in all versions of the Modicon M580, Modicon M340, Modicon Quantum, and Modicon Premium which could cause a Denial of Service when sending invalid breakpoint parameters to the controller over Modbus"
},
{
"lang": "es",
"value": "Una CWE-248: Existe una vulnerabilidad de Excepci\u00f3n no Detectada en todas las versiones de Modicon M580, Modicon M340, Modicon Quantum y Modicon Premium, que podr\u00eda generar una Denegaci\u00f3n de Servicio al enviar par\u00e1metros Breakpoint no v\u00e1lidos hacia el controlador sobre el protocolo Modbus."
}
],
"id": "CVE-2018-7855",
"lastModified": "2024-11-21T04:12:53.160",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-05-22T21:29:00.493",
"references": [
{
"source": "cybersecurity@se.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
},
{
"source": "cybersecurity@se.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0766"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2019-0767"
}
],
"sourceIdentifier": "cybersecurity@se.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-754"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
CVE-2018-7855
Vulnerability from fstec - Published: 14.05.2019{
"CVSS 2.0": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"CVSS 3.0": "AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"CVSS 4.0": null,
"remediation_\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": null,
"remediation_\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435": null,
"\u0412\u0435\u043d\u0434\u043e\u0440 \u041f\u041e": "Schneider Electric",
"\u0412\u0435\u0440\u0441\u0438\u044f \u041f\u041e": "- (Modicon Premium), - (Modicon Quantum), \u0434\u043e 3.10 (Modicon M340), \u0434\u043e 2.90 (Modicon M580)",
"\u0412\u043e\u0437\u043c\u043e\u0436\u043d\u044b\u0435 \u043c\u0435\u0440\u044b \u043f\u043e \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044e": "\u0414\u043b\u044f Modicon M580:\n\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u0441\u0435\u0442\u0438 \u0438 \u0432\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u0435 \u0431\u0440\u0430\u043d\u0434\u043c\u0430\u0443\u044d\u0440\u0430 \u0434\u043b\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u043e\u0440\u0442\u0443 502/TCP\n\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0439 \u0441\u0432\u044f\u0437\u0438 \u0432 \u0441\u043e\u043e\u0442\u0432\u0435\u0442\u0441\u0442\u0432\u0438\u0438 \u0441 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e\u043c \u00ab\u0421\u043f\u0440\u0430\u0432\u043e\u0447\u043d\u043e\u0435 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u043a\u0438\u0431\u0435\u0440\u0431\u0435\u0437\u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b Modicon Controllers\u00bb \u0432 \u0433\u043b\u0430\u0432\u0435 \u00ab\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0437\u0430\u0449\u0438\u0449\u0435\u043d\u043d\u043e\u0439 \u0441\u0432\u044f\u0437\u0438\u00bb:\nhttps://download.schneiderelectric.com/files?p_enDocType=User+guide\u0026p_File_Name=EIO0000001999.06.pdf\u0026p_Doc_Ref=EIO0000001999\n\u0418\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435 \u043c\u043e\u0434\u0443\u043b\u044f BMENOC \u0438 \u0441\u043b\u0435\u0434\u043e\u0432\u0430\u043d\u0438\u0435 \u0438\u043d\u0441\u0442\u0440\u0443\u043a\u0446\u0438\u044f\u043c \u0434\u043b\u044f \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u0444\u0443\u043d\u043a\u0446\u0438\u0438 IPSEC, \u043a\u0430\u043a \u043e\u043f\u0438\u0441\u0430\u043d\u043e \u0432 \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0435 \u00abModicon M580 - BMENOC03.1 \u041a\u043e\u043c\u043c\u0443\u043d\u0438\u043a\u0430\u0446\u0438\u0438 \u0447\u0435\u0440\u0435\u0437 Ethernet \u041c\u043e\u0434\u0443\u043b\u044c, \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e \u0443\u0441\u0442\u0430\u043d\u043e\u0432\u043a\u0435 \u0438 \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0435 \u00bb\u0432 \u0433\u043b\u0430\u0432\u0435\u00ab \u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 IPSEC \u00bb \u043a\u043e\u043c\u043c\u0443\u043d\u0438\u043a\u0430\u0446\u0438\u0438\u00bb:\nhttps://www.schneiderelectric.com/en/download/document/HRB62665/#page=1\u0026toolbar=1\u0026scrollbar=1\u0026statusbar=1\u0026view=fit\n\n\u0414\u043b\u044f Modicon M340:\n\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u0441\u0435\u0442\u0438 \u0438 \u0432\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u0435 \u0431\u0440\u0430\u043d\u0434\u043c\u0430\u0443\u044d\u0440\u0430 \u0434\u043b\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u043e\u0440\u0442\u0443 502/TCP\n\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0441\u043f\u0438\u0441\u043a\u0430 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430, \u0441\u043b\u0435\u0434\u0443\u044f \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u044f\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044f. \u00ab\u0420\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044f Modicon M340 \u0434\u043b\u044f \u043a\u043e\u043c\u043c\u0443\u043d\u0438\u043a\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0445 \u043c\u043e\u0434\u0443\u043b\u0435\u0439 \u0438 \u043f\u0440\u043e\u0446\u0435\u0441\u0441\u043e\u0440\u043e\u0432 Ethernet\u00bb \u0432 \u0433\u043b\u0430\u0432\u0435 \u00ab\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 \u043e\u0431\u043c\u0435\u043d\u0430 \u0441\u043e\u043e\u0431\u0449\u0435\u043d\u0438\u044f\u043c\u0438\u00bb:\nhttps://download.schneiderelectric.com/files?p_enDocType=User+guide\u0026p_File_Name=31007131_K01_000_16.pdf\u0026p_Doc_Ref=31007131K01000\n\n\u0414\u043b\u044f Modicon Premium:\n\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u0441\u0435\u0442\u0438 \u0438 \u0432\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u0435 \u0431\u0440\u0430\u043d\u0434\u043c\u0430\u0443\u044d\u0440\u0430 \u0434\u043b\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u043e\u0440\u0442\u0443 502/TCP\n\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0441\u043f\u0438\u0441\u043a\u0430 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430, \u0441\u043b\u0435\u0434\u0443\u044f \u0440\u0435\u043a\u043e\u043c\u0435\u043d\u0434\u0430\u0446\u0438\u044f\u043c \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u0430 \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044f. \u00ab\u041f\u0440\u0435\u043c\u0438\u0443\u043c \u0438 Atrium \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c EcoStruxure \u2122 Control Expert - \u0441\u0435\u0442\u0435\u0432\u044b\u0435 \u043c\u043e\u0434\u0443\u043b\u0438 Ethernet, \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044f\u00bb \u0432 \u0433\u043b\u0430\u0432\u0430\u0445 \u00ab\u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f / \u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 \u0441\u043b\u0443\u0436\u0431 TCP / IP / \u041f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u044b \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u0438 \u0441\u043e\u0435\u0434\u0438\u043d\u0435\u043d\u0438\u044f\u00bb:\nhttps://www.schneider-electric.com/en/download/document/35006192K01000/\n\n\u0414\u043b\u044f Modicon Quantum:\n\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0441\u0435\u0433\u043c\u0435\u043d\u0442\u0430\u0446\u0438\u0438 \u0441\u0435\u0442\u0438 \u0438 \u0432\u043d\u0435\u0434\u0440\u0435\u043d\u0438\u0435 \u0431\u0440\u0430\u043d\u0434\u043c\u0430\u0443\u044d\u0440\u0430 \u0434\u043b\u044f \u0431\u043b\u043e\u043a\u0438\u0440\u043e\u0432\u043a\u0438 \u043d\u0435\u0441\u0430\u043d\u043a\u0446\u0438\u043e\u043d\u0438\u0440\u043e\u0432\u0430\u043d\u043d\u043e\u0433\u043e \u0434\u043e\u0441\u0442\u0443\u043f\u0430 \u043a \u043f\u043e\u0440\u0442\u0443 502/TCP\n\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0430 \u0441\u043f\u0438\u0441\u043a\u0430 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044f \u0434\u043e\u0441\u0442\u0443\u043f\u0430, \u043a\u0430\u043a \u0443\u043f\u043e\u043c\u044f\u043d\u0443\u0442\u043e \u0432 \u00abQuantum \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c EcoStruxure \u2122 Control Expert - \u043a\u043e\u043d\u0444\u0438\u0433\u0443\u0440\u0430\u0446\u0438\u044f TCP / IP, \u0440\u0443\u043a\u043e\u0432\u043e\u0434\u0441\u0442\u0432\u043e \u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u0442\u0435\u043b\u044f\u00bb \u0432 \u0433\u043b\u0430\u0432\u0435 \u00ab\u041d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u0434\u043b\u044f \u043e\u0431\u043c\u0435\u043d\u0430 \u0434\u0430\u043d\u043d\u044b\u043c\u0438 \u0447\u0435\u0440\u0435\u0437 Ethernet / \u043e\u0431\u043c\u0435\u043d\u0430 \u0441\u043e\u043e\u0431\u0449\u0435\u043d\u0438\u044f\u043c\u0438 / \u043d\u0430\u0441\u0442\u0440\u043e\u0439\u043a\u0438 \u043e\u0431\u043c\u0435\u043d\u0430 \u0441\u043e\u043e\u0431\u0449\u0435\u043d\u0438\u044f\u043c\u0438 Quantum NOE Ethernet\u00bb:\nhttps://www.schneider-electric.com/en/download/document/33002467K01000/",
"\u0414\u0430\u0442\u0430 \u0432\u044b\u044f\u0432\u043b\u0435\u043d\u0438\u044f": "14.05.2019",
"\u0414\u0430\u0442\u0430 \u043f\u043e\u0441\u043b\u0435\u0434\u043d\u0435\u0433\u043e \u043e\u0431\u043d\u043e\u0432\u043b\u0435\u043d\u0438\u044f": "23.03.2021",
"\u0414\u0430\u0442\u0430 \u043f\u0443\u0431\u043b\u0438\u043a\u0430\u0446\u0438\u0438": "14.06.2019",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440": "BDU:2019-02052",
"\u0418\u0434\u0435\u043d\u0442\u0438\u0444\u0438\u043a\u0430\u0442\u043e\u0440\u044b \u0434\u0440\u0443\u0433\u0438\u0445 \u0441\u0438\u0441\u0442\u0435\u043c \u043e\u043f\u0438\u0441\u0430\u043d\u0438\u0439 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "CVE-2018-7855",
"\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438": "\u0418\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f \u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u0438 \u043e\u0442\u0441\u0443\u0442\u0441\u0442\u0432\u0443\u0435\u0442",
"\u041a\u043b\u0430\u0441\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043a\u043e\u0434\u0430",
"\u041d\u0430\u0437\u0432\u0430\u043d\u0438\u0435 \u041f\u041e": "Modicon Premium, Modicon Quantum, Modicon M340, Modicon M580",
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u041e\u0421 \u0438 \u0442\u0438\u043f \u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0439 \u043f\u043b\u0430\u0442\u0444\u043e\u0440\u043c\u044b": null,
"\u041d\u0430\u0438\u043c\u0435\u043d\u043e\u0432\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u043e\u0433\u043e \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u0430 Modicon, \u0441\u0432\u044f\u0437\u0430\u043d\u043d\u0430\u044f \u0441 \u043d\u0435\u043e\u0431\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u043d\u044b\u043c \u0438\u0441\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c, \u043f\u043e\u0437\u0432\u043e\u043b\u044f\u044e\u0449\u0430\u044f \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438",
"\u041d\u0430\u043b\u0438\u0447\u0438\u0435 \u044d\u043a\u0441\u043f\u043b\u043e\u0439\u0442\u0430": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "\u041d\u0435 \u043f\u0435\u0440\u0435\u0445\u0432\u0430\u0447\u0435\u043d\u043d\u043e\u0435 \u0438\u0441\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435 (CWE-248)",
"\u041e\u043f\u0438\u0441\u0430\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0423\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u044c \u043c\u0438\u043a\u0440\u043e\u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0433\u043e \u043e\u0431\u0435\u0441\u043f\u0435\u0447\u0435\u043d\u0438\u044f \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u0438\u0440\u0443\u0435\u043c\u043e\u0433\u043e \u043b\u043e\u0433\u0438\u0447\u0435\u0441\u043a\u043e\u0433\u043e \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440\u0430 Modicon \u0441\u0432\u044f\u0437\u0430\u043d\u0430 \u0441 \u043d\u0435\u043e\u0431\u0440\u0430\u0431\u043e\u0442\u0430\u043d\u043d\u044b\u043c \u0438\u0441\u043a\u043b\u044e\u0447\u0435\u043d\u0438\u0435\u043c. \u042d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u044f \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438 \u043c\u043e\u0436\u0435\u0442 \u043f\u043e\u0437\u0432\u043e\u043b\u0438\u0442\u044c \u043d\u0430\u0440\u0443\u0448\u0438\u0442\u0435\u043b\u044e, \u0434\u0435\u0439\u0441\u0442\u0432\u0443\u044e\u0449\u0435\u043c\u0443 \u0443\u0434\u0430\u043b\u0435\u043d\u043d\u043e, \u0432\u044b\u0437\u0432\u0430\u0442\u044c \u043e\u0442\u043a\u0430\u0437 \u0432 \u043e\u0431\u0441\u043b\u0443\u0436\u0438\u0432\u0430\u043d\u0438\u0438 \u043f\u0443\u0442\u0435\u043c \u043e\u0442\u043f\u0440\u0430\u0432\u043a\u0438 \u043d\u0435\u0434\u043e\u043f\u0443\u0441\u0442\u0438\u043c\u044b\u0445 \u043f\u0430\u0440\u0430\u043c\u0435\u0442\u0440\u043e\u0432 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u044c\u043d\u043e\u0439 \u0442\u043e\u0447\u043a\u0438 \u043d\u0430 \u043a\u043e\u043d\u0442\u0440\u043e\u043b\u043b\u0435\u0440 \u0441 \u0438\u0441\u043f\u043e\u043b\u044c\u0437\u043e\u0432\u0430\u043d\u0438\u0435\u043c \u043f\u0440\u043e\u0442\u043e\u043a\u043e\u043b\u0430 Modbus",
"\u041f\u043e\u0441\u043b\u0435\u0434\u0441\u0442\u0432\u0438\u044f \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": null,
"\u041f\u0440\u043e\u0447\u0430\u044f \u0438\u043d\u0444\u043e\u0440\u043c\u0430\u0446\u0438\u044f": "-",
"\u0421\u0432\u044f\u0437\u044c \u0441 \u0438\u043d\u0446\u0438\u0434\u0435\u043d\u0442\u0430\u043c\u0438 \u0418\u0411": "\u0414\u0430\u043d\u043d\u044b\u0435 \u0443\u0442\u043e\u0447\u043d\u044f\u044e\u0442\u0441\u044f",
"\u0421\u043e\u0441\u0442\u043e\u044f\u043d\u0438\u0435 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041e\u043f\u0443\u0431\u043b\u0438\u043a\u043e\u0432\u0430\u043d\u0430",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u0443\u0441\u0442\u0440\u0430\u043d\u0435\u043d\u0438\u044f": "\u041e\u0440\u0433\u0430\u043d\u0438\u0437\u0430\u0446\u0438\u043e\u043d\u043d\u044b\u0435 \u043c\u0435\u0440\u044b",
"\u0421\u043f\u043e\u0441\u043e\u0431 \u044d\u043a\u0441\u043f\u043b\u0443\u0430\u0442\u0430\u0446\u0438\u0438": "\u041c\u0430\u043d\u0438\u043f\u0443\u043b\u0438\u0440\u043e\u0432\u0430\u043d\u0438\u0435 \u0440\u0435\u0441\u0443\u0440\u0441\u0430\u043c\u0438",
"\u0421\u0441\u044b\u043b\u043a\u0438 \u043d\u0430 \u0438\u0441\u0442\u043e\u0447\u043d\u0438\u043a\u0438": "https://nvd.nist.gov/vuln/detail/CVE-2018-7855\nhttps://www.schneider-electric.com/en/download/document/SEVD-2019-134-11/",
"\u0421\u0442\u0430\u0442\u0443\u0441 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u041f\u043e\u0434\u0442\u0432\u0435\u0440\u0436\u0434\u0435\u043d\u0430 \u043f\u0440\u043e\u0438\u0437\u0432\u043e\u0434\u0438\u0442\u0435\u043b\u0435\u043c",
"\u0422\u0438\u043f \u041f\u041e": "\u041f\u041e \u043f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e-\u0430\u043f\u043f\u0430\u0440\u0430\u0442\u043d\u043e\u0433\u043e \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u0430 \u0410\u0421\u0423 \u0422\u041f, \u041f\u0440\u043e\u0433\u0440\u0430\u043c\u043c\u043d\u043e\u0435 \u0441\u0440\u0435\u0434\u0441\u0442\u0432\u043e \u0410\u0421\u0423 \u0422\u041f",
"\u0422\u0438\u043f \u043e\u0448\u0438\u0431\u043a\u0438 CWE": "CWE-248",
"\u0423\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 \u0443\u044f\u0437\u0432\u0438\u043c\u043e\u0441\u0442\u0438": "\u0421\u0440\u0435\u0434\u043d\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 2.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 5)\n\u0412\u044b\u0441\u043e\u043a\u0438\u0439 \u0443\u0440\u043e\u0432\u0435\u043d\u044c \u043e\u043f\u0430\u0441\u043d\u043e\u0441\u0442\u0438 (\u0431\u0430\u0437\u043e\u0432\u0430\u044f \u043e\u0446\u0435\u043d\u043a\u0430 CVSS 3.0 \u0441\u043e\u0441\u0442\u0430\u0432\u043b\u044f\u0435\u0442 7,5)"
}
CNVD-2019-15745
Vulnerability from cnvd - Published: 2019-05-29用户可参考如下厂商提供的安全补丁以修复该漏洞: https://www.schneider-electric.com/
| Name | ['Schneider Electric Modicon M580', 'Schneider Electric Modicon M340', 'Schneider Electric Modicon Quantum', 'Schneider Electric Modicon Premium'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2018-7855",
"cveUrl": "http://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2018-7855"
}
},
"description": "Schneider Electric Modicon M580\u3001M340\u662f\u4e00\u6b3e\u53ef\u7f16\u7a0b\u81ea\u52a8\u5316\u63a7\u5236\u5668\u3002\n\nSchneider Electric Modicon M580\u3001M340\u5b58\u5728\u975e\u6cd5\u65ad\u70b9\u53c2\u6570\u5904\u7406\u6f0f\u6d1e\uff0c\u5141\u8bb8\u8fdc\u7a0b\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u63d0\u4ea4\u7279\u6b8a\u7684\u8bf7\u6c42\uff0c\u53ef\u8fdb\u884c\u62d2\u7edd\u670d\u52a1\u653b\u51fb\u3002",
"discovererName": "Schneider Electric",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u5382\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u8865\u4e01\u4ee5\u4fee\u590d\u8be5\u6f0f\u6d1e\uff1a\r\nhttps://www.schneider-electric.com/",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2019-15745",
"openTime": "2019-05-29",
"patchDescription": "Schneider Electric Modicon M580\u3001M340\u662f\u4e00\u6b3e\u53ef\u7f16\u7a0b\u81ea\u52a8\u5316\u63a7\u5236\u5668\u3002\r\n\r\nSchneider Electric Modicon M580\u3001M340\u5b58\u5728\u975e\u6cd5\u65ad\u70b9\u53c2\u6570\u5904\u7406\u6f0f\u6d1e\uff0c\u5141\u8bb8\u8fdc\u7a0b\u653b\u51fb\u8005\u5229\u7528\u6f0f\u6d1e\u63d0\u4ea4\u7279\u6b8a\u7684\u8bf7\u6c42\uff0c\u53ef\u8fdb\u884c\u62d2\u7edd\u670d\u52a1\u653b\u51fb\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Schneider Electric Modicon\u975e\u6cd5\u65ad\u70b9\u53c2\u6570\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": [
"Schneider Electric Modicon M580",
"Schneider Electric Modicon M340",
"Schneider Electric Modicon Quantum",
"Schneider Electric Modicon Premium"
]
},
"referenceLink": "https://web.nvd.nist.gov//vuln/detail/CVE-2018-7855",
"serverity": "\u4e2d",
"submitTime": "2019-05-22",
"title": "Schneider Electric Modicon\u975e\u6cd5\u65ad\u70b9\u53c2\u6570\u62d2\u7edd\u670d\u52a1\u6f0f\u6d1e"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.