Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2020-28385 (GCVE-0-2020-28385)
Vulnerability from cvelistv5 – Published: 2021-03-15 17:03 – Updated: 2024-08-04 16:33- CWE-787 - Out-of-bounds Write
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Solid Edge SE2020 |
Affected:
All versions < SE2020MP13
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-04T16:33:59.024Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"tags": [
"x_refsource_CONFIRM",
"x_transferred"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "Solid Edge SE2020",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All versions \u003c SE2020MP13"
}
]
},
{
"product": "Solid Edge SE2021",
"vendor": "Siemens",
"versions": [
{
"status": "affected",
"version": "All Versions \u003c SE2021MP4"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787: Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2021-04-22T20:42:20.000Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"tags": [
"x_refsource_CONFIRM"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-28385",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Solid Edge SE2020",
"version": {
"version_data": [
{
"version_value": "All versions \u003c SE2020MP13"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2020-28385",
"datePublished": "2021-03-15T17:03:30.000Z",
"dateReserved": "2020-11-10T00:00:00.000Z",
"dateUpdated": "2024-08-04T16:33:59.024Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
GHSA-MGC5-74JH-74QV
Vulnerability from github – Published: 2022-05-24 17:44 – Updated: 2022-05-24 17:44A vulnerability has been identified in Solid Edge SE2020 (All Versions < SE2020MP13), Solid Edge SE2021 (All Versions < SE2021MP3), Solid Edge SE2021 (SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)
{
"affected": [],
"aliases": [
"CVE-2020-28385"
],
"database_specific": {
"cwe_ids": [
"CWE-787"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-03-15T17:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in Solid Edge SE2020 (All Versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP3), Solid Edge SE2021 (SE2021MP3). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)",
"id": "GHSA-mgc5-74jh-74qv",
"modified": "2022-05-24T17:44:32Z",
"published": "2022-05-24T17:44:32Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2020-28385"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"type": "WEB",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
],
"schema_version": "1.4.0",
"severity": []
}
CERTFR-2021-AVI-176
Vulnerability from certfr_avis - Published: 2021-03-10 - Updated: 2021-03-10
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et une atteinte à l'intégrité des données.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | SENTRON PAC3200 versions antérieures à 2.4.7 | ||
| Siemens | N/A | SENTRON 3VA COM100/800, 3VA DSP800, PAC2200 toutes versions | ||
| Siemens | N/A | SCALANCE XM400 et XR500 versions antérieures à 6.2 | ||
| Siemens | N/A | SIMATIC S7-PLCSIM version 5.4 | ||
| Siemens | N/A | RUGGEDCOM RM1224, SCALANCE M-800 et Scalance S615 versions 4.3 et ultérieures | ||
| Siemens | N/A | SENTRON PAC3220 versions antérieures à 3.2.0 | ||
| Siemens | N/A | module Mendix Forgot Password versions antérieures à 3.2.1 | ||
| Siemens | N/A | SIMATIC NET CM 1542-1 toutes versions | ||
| Siemens | N/A | Solid Edge SE2020 versions antérieures à SE2020MP13 | ||
| Siemens | N/A | SINEMA remote connect server versions antérieures à 3.0 | ||
| Siemens | N/A | SCALANCE SC-600 versions antérieures à 2.1.3 | ||
| Siemens | N/A | LOGO! 8 BM toutes versions (y compris les versions SIPLUS) | ||
| Siemens | N/A | PLUSCONTROL 1st Gen toutes versions | ||
| Siemens | N/A | SENTRON PAC4200 versions antérieures à 2.3.0 | ||
| Siemens | N/A | Luxion KeyShot versions antérieures à 10.1 | ||
| Siemens | N/A | SCALANCE X300WG et Xx200 versions antérieures à 4.1 | ||
| Siemens | N/A | SIMATIC MV400 versions antérieures à 7.0.6 | ||
| Siemens | N/A | Solid Edge SE2021 versions antérieures à SE2021MP3 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "SENTRON PAC3200 versions ant\u00e9rieures \u00e0 2.4.7",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON 3VA COM100/800, 3VA DSP800, PAC2200 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XM400 et XR500 versions ant\u00e9rieures \u00e0 6.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC S7-PLCSIM version 5.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RM1224, SCALANCE M-800 et Scalance S615 versions 4.3 et ult\u00e9rieures",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON PAC3220 versions ant\u00e9rieures \u00e0 3.2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "module Mendix Forgot Password versions ant\u00e9rieures \u00e0 3.2.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CM 1542-1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2020 versions ant\u00e9rieures \u00e0 SE2020MP13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA remote connect server versions ant\u00e9rieures \u00e0 3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE SC-600 versions ant\u00e9rieures \u00e0 2.1.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "LOGO! 8 BM toutes versions (y compris les versions SIPLUS)",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PLUSCONTROL 1st Gen toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON PAC4200 versions ant\u00e9rieures \u00e0 2.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Luxion KeyShot versions ant\u00e9rieures \u00e0 10.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X300WG et Xx200 versions ant\u00e9rieures \u00e0 4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV400 versions ant\u00e9rieures \u00e0 7.0.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2021 versions ant\u00e9rieures \u00e0 SE2021MP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-25667",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25667"
},
{
"name": "CVE-2020-28388",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28388"
},
{
"name": "CVE-2021-27381",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27381"
},
{
"name": "CVE-2021-25673",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25673"
},
{
"name": "CVE-2020-28387",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28387"
},
{
"name": "CVE-2020-25241",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25241"
},
{
"name": "CVE-2021-22647",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22647"
},
{
"name": "CVE-2021-22643",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22643"
},
{
"name": "CVE-2021-25672",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25672"
},
{
"name": "CVE-2021-27380",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27380"
},
{
"name": "CVE-2021-22649",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22649"
},
{
"name": "CVE-2021-22651",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22651"
},
{
"name": "CVE-2021-25676",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25676"
},
{
"name": "CVE-2021-25674",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25674"
},
{
"name": "CVE-2021-22645",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-22645"
},
{
"name": "CVE-2019-3823",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-3823"
},
{
"name": "CVE-2020-28385",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28385"
},
{
"name": "CVE-2019-10926",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10926"
},
{
"name": "CVE-2020-13987",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-13987"
},
{
"name": "CVE-2020-27632",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27632"
},
{
"name": "CVE-2020-25239",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25239"
},
{
"name": "CVE-2020-25236",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25236"
},
{
"name": "CVE-2021-25675",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25675"
},
{
"name": "CVE-2020-25240",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25240"
},
{
"name": "CVE-2019-10925",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-10925"
},
{
"name": "CVE-2020-17437",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-17437"
}
],
"initial_release_date": "2021-03-10T00:00:00",
"last_revision_date": "2021-03-10T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-176",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-03-10T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et une atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-599268 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-599268.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-979775 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-979775.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-541018 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-541018.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-715184 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-936080 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-936080.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-231216 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-231216.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-783481 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-783481.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-296266 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-296266.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-731317 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-731317.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-256092 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-256092.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-344238 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-344238.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-917115 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917115.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-816980 du 09 mars 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-816980.pdf"
}
]
}
CERTFR-2021-AVI-255
Vulnerability from certfr_avis - Published: 2021-04-14 - Updated: 2021-04-14
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | LOGO! Soft Comfort toutes versions | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2019 R2 | ||
| Siemens | N/A | Solid Edge SE2021 versions antérieures à SE2021MP4 | ||
| Siemens | N/A | SIMATIC NET CP 443-1 Advanced (incl. SIPLUSvariants) versions antérieures à V3.2.9 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2019 R3 | ||
| Siemens | N/A | Nucleus NET versions antérieures à 5.2 | ||
| Siemens | N/A | TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUSNET variants) versions antérieures à V2.6.0 | ||
| Siemens | N/A | SiNVR/SiVMS Video Server toutes versions | ||
| Siemens | N/A | Nucleus RTOS versions contenant le module DNS affecté | ||
| Siemens | N/A | SIMATIC NET CP 343-1 Advanced (incl. SIPLUSvariants) versions antérieures à V3.0.44 | ||
| Siemens | N/A | Solid Edge SE2020 toutes versions | ||
| Siemens | N/A | SIMATIC NET CP 343-1 Lean (incl. SIPLUS vari-ants) versions antérieures à V3.1.1 | ||
| Siemens | N/A | SIMATIC NET CP 443-5 Basic (incl. SIPLUS vari-ants) toutes versions | ||
| Siemens | N/A | Opcenter Quality versions antérieures à 12.2 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2019 R1 | ||
| Siemens | N/A | SIMATIC NET CP 443-5 Extended toutes versions | ||
| Siemens | N/A | VSTAR versions contenant le module DNS affecté | ||
| Siemens | N/A | Control Center Server (CCS) toutes versions | ||
| Siemens | N/A | TIM 4R-IE (incl. SIPLUS NET variants) toutes versions | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2020 R1 | ||
| Siemens | N/A | SINEMA Remote Connect Server versions antérieures à 3.0 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2020 R2 | ||
| Siemens | N/A | SIMATIC NET CP 343-1 Standard (incl. SIPLUSvariants) versions antérieures à V3.1.1 | ||
| Siemens | N/A | SIMATIC NET CP 443-1 Standard (incl. SIPLUSvariants) versions antérieures à V3.2.9 | ||
| Siemens | N/A | SIMATIC NET CP 342-5 (incl. SIPLUS variants) toutes versions | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2018 R2 | ||
| Siemens | N/A | Nucleus ReadyStart toutes versions | ||
| Siemens | N/A | Nucleus 4 versions antérieures à 4.1.0 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2018 R3 | ||
| Siemens | N/A | QMS Automotive versions antérieures à 12.30 | ||
| Siemens | N/A | Tecnomatix RobotExpert versions antérieures à 16.1 | ||
| Siemens | N/A | TIM 3V-IE DNP3 (incl. SIPLUS NET variants) versions antérieures à V3.1.0 | ||
| Siemens | N/A | Siveillance Video Open Network Bridge:2020 R3 | ||
| Siemens | N/A | Nucleus Source Code versions contenant le module DNS affecté | ||
| Siemens | N/A | TIM 4R-IE DNP3 (incl. SIPLUS NET variants) toutes versions | ||
| Siemens | N/A | SIMOTICS CONNECT 400 toutes verions |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "LOGO! Soft Comfort toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2019 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2021 versions ant\u00e9rieures \u00e0 SE2021MP4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 443-1 Advanced (incl. SIPLUSvariants) versions ant\u00e9rieures \u00e0 V3.2.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2019 R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus NET versions ant\u00e9rieures \u00e0 5.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE / TIM 3V-IE Advanced (incl. SIPLUSNET variants) versions ant\u00e9rieures \u00e0 V2.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiNVR/SiVMS Video Server toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus RTOS versions contenant le module DNS affect\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 343-1 Advanced (incl. SIPLUSvariants) versions ant\u00e9rieures \u00e0 V3.0.44",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2020 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 343-1 Lean (incl. SIPLUS vari-ants) versions ant\u00e9rieures \u00e0 V3.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 443-5 Basic (incl. SIPLUS vari-ants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Opcenter Quality versions ant\u00e9rieures \u00e0 12.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2019 R1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 443-5 Extended toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "VSTAR versions contenant le module DNS affect\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Control Center Server (CCS) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 4R-IE (incl. SIPLUS NET variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2020 R1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEMA Remote Connect Server versions ant\u00e9rieures \u00e0 3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2020 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 343-1 Standard (incl. SIPLUSvariants) versions ant\u00e9rieures \u00e0 V3.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 443-1 Standard (incl. SIPLUSvariants) versions ant\u00e9rieures \u00e0 V3.2.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC NET CP 342-5 (incl. SIPLUS variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2018 R2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus ReadyStart toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus 4 versions ant\u00e9rieures \u00e0 4.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2018 R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "QMS Automotive versions ant\u00e9rieures \u00e0 12.30",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix RobotExpert versions ant\u00e9rieures \u00e0 16.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 3V-IE DNP3 (incl. SIPLUS NET variants) versions ant\u00e9rieures \u00e0 V3.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video Open Network Bridge:2020 R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus Source Code versions contenant le module DNS affect\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIM 4R-IE DNP3 (incl. SIPLUS NET variants) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMOTICS CONNECT 400 toutes verions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-27009",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27009"
},
{
"name": "CVE-2015-7855",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7855"
},
{
"name": "CVE-2019-18339",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18339"
},
{
"name": "CVE-2016-1547",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-1547"
},
{
"name": "CVE-2015-7973",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7973"
},
{
"name": "CVE-2016-4953",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-4953"
},
{
"name": "CVE-2021-27389",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27389"
},
{
"name": "CVE-2021-27382",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27382"
},
{
"name": "CVE-2020-27736",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27736"
},
{
"name": "CVE-2021-27380",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27380"
},
{
"name": "CVE-2015-5219",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-5219"
},
{
"name": "CVE-2016-1550",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-1550"
},
{
"name": "CVE-2015-7977",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7977"
},
{
"name": "CVE-2015-7705",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7705"
},
{
"name": "CVE-2021-27392",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27392"
},
{
"name": "CVE-2019-19956",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19956"
},
{
"name": "CVE-2021-25663",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25663"
},
{
"name": "CVE-2020-15795",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-15795"
},
{
"name": "CVE-2015-8138",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-8138"
},
{
"name": "CVE-2016-4954",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-4954"
},
{
"name": "CVE-2021-25664",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25664"
},
{
"name": "CVE-2020-25243",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25243"
},
{
"name": "CVE-2015-7974",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7974"
},
{
"name": "CVE-2015-8214",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-8214"
},
{
"name": "CVE-2019-19299",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19299"
},
{
"name": "CVE-2020-28385",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28385"
},
{
"name": "CVE-2021-25678",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25678"
},
{
"name": "CVE-2020-7595",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-7595"
},
{
"name": "CVE-2021-27393",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27393"
},
{
"name": "CVE-2020-25244",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25244"
},
{
"name": "CVE-2019-18340",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-18340"
},
{
"name": "CVE-2021-25670",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25670"
},
{
"name": "CVE-2015-7979",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7979"
},
{
"name": "CVE-2015-7871",
"url": "https://www.cve.org/CVERecord?id=CVE-2015-7871"
},
{
"name": "CVE-2020-27738",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27738"
},
{
"name": "CVE-2019-19298",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19298"
},
{
"name": "CVE-2020-26997",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-26997"
},
{
"name": "CVE-2019-19291",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19291"
},
{
"name": "CVE-2020-27737",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27737"
},
{
"name": "CVE-2019-19297",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19297"
},
{
"name": "CVE-2016-1548",
"url": "https://www.cve.org/CVERecord?id=CVE-2016-1548"
},
{
"name": "CVE-2021-25677",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25677"
},
{
"name": "CVE-2019-19296",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-19296"
}
],
"initial_release_date": "2021-04-14T00:00:00",
"last_revision_date": "2021-04-14T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-255",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-04-14T00:00:00.000000"
}
],
"risks": [
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Ex\u00e9cution de code arbitraire"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service et un\ncontournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-788287 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-788287.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-248289 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-853866 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-853866.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-185699 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-983300 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-983300.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-844761 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-844761.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-163226 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-163226.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-763427 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-763427.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-497656 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-497656.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-761617 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761617.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-669158 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-669158.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-574442 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-705111 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-292794 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-292794.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-761844 du 13 avril 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-761844.pdf"
}
]
}
CNVD-2021-16441
Vulnerability from cnvd - Published: 2021-03-11用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf
| Name | Siemens Solid Edge SE2021 SE2021MP3 |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2020-28385"
}
},
"description": "Siemens Solid Edge\u662f\u5fb7\u56fdSiemens\u516c\u53f8\u7684\u4e00\u6b3e\u4e09\u7ef4CAD\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u53ef\u7528\u4e8e\u96f6\u4ef6\u8bbe\u8ba1\u3001\u88c5\u914d\u8bbe\u8ba1\u3001\u94a3\u91d1\u8bbe\u8ba1\u3001\u710a\u63a5\u8bbe\u8ba1\u7b49\u884c\u4e1a\u3002\n\nSiemens Solid Edge\u5b58\u5728\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u662f\u7531\u4e8e\u53d7\u5f71\u54cd\u7684\u5e94\u7528\u7a0b\u5e8f\u5728\u89e3\u6790DFT\u6587\u4ef6\u65f6\u7f3a\u5c11\u5bf9\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\u7684\u6b63\u786e\u9a8c\u8bc1\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6b64\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-16441",
"openTime": "2021-03-11",
"patchDescription": "Siemens Solid Edge\u662f\u5fb7\u56fdSiemens\u516c\u53f8\u7684\u4e00\u6b3e\u4e09\u7ef4CAD\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u53ef\u7528\u4e8e\u96f6\u4ef6\u8bbe\u8ba1\u3001\u88c5\u914d\u8bbe\u8ba1\u3001\u94a3\u91d1\u8bbe\u8ba1\u3001\u710a\u63a5\u8bbe\u8ba1\u7b49\u884c\u4e1a\u3002\r\n\r\nSiemens Solid Edge\u5b58\u5728\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u662f\u7531\u4e8e\u53d7\u5f71\u54cd\u7684\u5e94\u7528\u7a0b\u5e8f\u5728\u89e3\u6790DFT\u6587\u4ef6\u65f6\u7f3a\u5c11\u5bf9\u7528\u6237\u63d0\u4f9b\u7684\u6570\u636e\u7684\u6b63\u786e\u9a8c\u8bc1\u3002\u653b\u51fb\u8005\u53ef\u5229\u7528\u6b64\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Solid Edge\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e\u7684\u8865\u4e01",
"products": {
"product": "Siemens Solid Edge SE2021 SE2021MP3"
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"serverity": "\u9ad8",
"submitTime": "2021-03-09",
"title": "Siemens Solid Edge\u8d8a\u754c\u5199\u5165\u6f0f\u6d1e"
}
FKIE_CVE-2020-28385
Vulnerability from fkie_nvd - Published: 2021-03-15 17:15 - Updated: 2024-11-21 05:22| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf | Patch, Vendor Advisory | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf | Patch, Vendor Advisory | |
| productcert@siemens.com | https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06 | Third Party Advisory, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06 | Third Party Advisory, US Government Resource |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | solid_edge | * | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2020 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7AF39DFE-A31B-4324-BB62-0B446ACA04B7",
"versionEndExcluding": "se2020",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*",
"matchCriteriaId": "07440B76-B975-4946-8A97-38C564D240E4",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*",
"matchCriteriaId": "5F0A748E-BB6F-4604-8024-F50DC0C20EAF",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*",
"matchCriteriaId": "F4F37267-6B37-46A4-B9F9-4264BEC922D1",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*",
"matchCriteriaId": "CB1DC54B-E715-4425-B6B6-900F2CFBCE03",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack12:*:*:*:*:*:*",
"matchCriteriaId": "1CC1A49B-907A-4317-B7A7-4E85D9C0E386",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*",
"matchCriteriaId": "2F495722-39BD-4BA1-A643-C7D0BA81CC21",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*",
"matchCriteriaId": "7B776512-BF3D-4F70-BD58-AFF8E1B03EE2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*",
"matchCriteriaId": "99E05299-50FD-4292-9978-8E05C1483FE2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*",
"matchCriteriaId": "2447D05B-2634-4895-B7B0-6F7DBB9D2EC2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*",
"matchCriteriaId": "CBBD39F3-790F-4017-A57E-6EFC314F0557",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*",
"matchCriteriaId": "B4387BFA-8A98-433E-9EF7-B29226C195A7",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*",
"matchCriteriaId": "9E380F66-C11C-472B-9B71-7CB4AF4FABDC",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*",
"matchCriteriaId": "0CF4ACE1-B069-4007-8142-7F90015BBE9D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
"matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
"matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
"matchCriteriaId": "756343AA-DB57-40F7-94FA-84BFCDEB6159",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
"matchCriteriaId": "36B0DD28-653E-4069-AB5A-38F8EFEB36CA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en Solid Edge SE2020 (Todas las versiones anteriores a SE2020MP13), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP4). Las aplicaciones afectadas carecen de una comprobaci\u00f3n apropiada de los datos proporcionados por el usuario al analizar archivos DFT. Esto podr\u00eda resultar en una escritura fuera de l\u00edmites m\u00e1s all\u00e1 del final de una estructura asignada. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual (ZDI-CAN-12049)"
}
],
"id": "CVE-2020-28385",
"lastModified": "2024-11-21T05:22:41.777",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-03-15T17:15:20.567",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
GSD-2020-28385
Vulnerability from gsd - Updated: 2023-12-13 01:22{
"GSD": {
"alias": "CVE-2020-28385",
"description": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)",
"id": "GSD-2020-28385"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2020-28385"
],
"details": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)",
"id": "GSD-2020-28385",
"modified": "2023-12-13T01:22:01.575379Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-28385",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "Solid Edge SE2020",
"version": {
"version_data": [
{
"version_value": "All versions \u003c SE2020MP13"
}
]
}
},
{
"product_name": "Solid Edge SE2021",
"version": {
"version_data": [
{
"version_value": "All Versions \u003c SE2021MP4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-787: Out-of-bounds Write"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
"refsource": "CONFIRM",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
"refsource": "CONFIRM",
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "se2020",
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack10:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack11:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack12:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack4:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack5:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack6:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack7:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack8:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2020:maintenance_pack9:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2020-28385"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in Solid Edge SE2020 (All versions \u003c SE2020MP13), Solid Edge SE2021 (All Versions \u003c SE2021MP4). Affected applications lack proper validation of user-supplied data when parsing DFT files. This could result in an out of bounds write past the end of an allocated structure. An attacker could leverage this vulnerability to execute code in the context of the current process. (ZDI-CAN-12049)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
},
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-715184.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf",
"refsource": "CONFIRM",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-574442.pdf"
},
{
"name": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06",
"refsource": "CONFIRM",
"tags": [
"Third Party Advisory",
"US Government Resource"
],
"url": "https://us-cert.cisa.gov/ics/advisories/icsa-21-103-06"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": true
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2021-12-10T21:36Z",
"publishedDate": "2021-03-15T17:15Z"
}
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.