CVE-2021-31881 (GCVE-0-2021-31881)
Vulnerability from cvelistv5 – Published: 2021-11-09 11:31 – Updated: 2025-03-11 09:47- CWE-125 - Out-of-bounds Read
| Vendor | Product | Version | |||||||
|---|---|---|---|---|---|---|---|---|---|
| Siemens | Capital Embedded AR Classic 431-422 |
Affected:
0 , < *
(custom)
|
|||||||
|
|||||||||
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T23:10:30.649Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "Capital Embedded AR Classic 431-422",
"vendor": "Siemens",
"versions": [
{
"lessThan": "*",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unknown",
"product": "Capital Embedded AR Classic R20-11",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V2303",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)"
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.1,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-125",
"description": "CWE-125: Out-of-bounds Read",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-03-11T09:47:40.916Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"tags": [
"x_refsource_MISC"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
},
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2021-31881",
"datePublished": "2021-11-09T11:31:54.000Z",
"dateReserved": "2021-04-29T00:00:00.000Z",
"dateUpdated": "2025-03-11T09:47:40.916Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
FKIE_CVE-2021-31881
Vulnerability from fkie_nvd - Published: 2021-11-09 12:15 - Updated: 2024-11-21 06:067.5 (High) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-044112.html | ||
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-114589.html | ||
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/html/ssa-620288.html | ||
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | Vendor Advisory | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | Vendor Advisory | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf | ||
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf |
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | capital_vstar | * | |
| siemens | nucleus_net | * | |
| siemens | nucleus_readystart_v3 | * | |
| siemens | nucleus_source_code | * | |
| siemens | apogee_modular_building_controller_firmware | * | |
| siemens | apogee_modular_building_controller | - | |
| siemens | apogee_modular_equiment_controller_firmware | * | |
| siemens | apogee_modular_equiment_controller | - | |
| siemens | apogee_pxc_compact_firmware | * | |
| siemens | apogee_pxc_compact | - | |
| siemens | apogee_pxc_modular_firmware | * | |
| siemens | apogee_pxc_modular | - | |
| siemens | talon_tc_compact_firmware | * | |
| siemens | talon_tc_compact | - | |
| siemens | talon_tc_modular_firmware | * | |
| siemens | talon_tc_modular | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*",
"matchCriteriaId": "3EC45D63-0FB7-4995-AF45-B41F6EF6A9E2",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7A987CFB-4A41-4F82-8C7F-31DE8F0650DE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2CBFE833-3471-480B-B0F1-A947BF4F94D8",
"versionEndExcluding": "2012.08",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*",
"matchCriteriaId": "07DAF9C3-B56A-4F40-B90B-D0DE96869A44",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "60FAD4D8-54FA-4721-954E-4AD77020B189",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B5F978E7-3DD9-4948-BFFB-E7273003477B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "ACCB699F-4F10-47BD-8890-047380972BE1",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*",
"matchCriteriaId": "7945BF7D-AB3A-4285-9C58-D56149ADFC15",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "105A6FFB-1176-4021-868D-3D6CE77113B2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8E2E8B0F-EBBC-4BCC-BE2A-20DCB506DF7F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "C6BE40AF-B7A4-498A-943E-11AA9393A3D6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D9485F0B-03E0-4442-B615-2DA91AE1CD00",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "0CA14719-C655-4BED-AE8D-B9C983847AE4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*",
"matchCriteriaId": "46D32EF0-8AEC-4594-8928-45F34DC60600",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1F3470FD-BEBE-465F-A189-F4CEDD0F6815",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*",
"matchCriteriaId": "00C647D8-1725-42FA-8042-6C413EE67573",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in Capital Embedded AR Classic 431-422 (All versions), Capital Embedded AR Classic R20-11 (All versions \u003c V2303). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)"
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en APOGEE MBC (PPC) (BACnet) (Todas las versiones), APOGEE MBC (PPC) (P2 Ethernet) (Todas las versiones), APOGEE MEC (PPC) (BACnet) (Todas las versiones), APOGEE MEC (PPC) (P2 Ethernet) (Todas las versiones), APOGEE PXC Compact (BACnet) (Todas las versiones anteriores a V3. 5.4), APOGEE PXC Compact (P2 Ethernet) (Todas las versiones anteriores a V2.8.19), APOGEE PXC Modular (BACnet) (Todas las versiones anteriores a V3. 5.4), APOGEE PXC Modular (P2 Ethernet) (Todas las versiones anteriores a V2.8.19), Capital VSTAR (Todas las versiones con opciones de Ethernet habilitadas), Desigo PXC00-E.D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6. 30.016), Desigo PXC00-U (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC001-E.D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC100-E.D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30. 016), Desigo PXC12-E.D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC128-U (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC200-E.D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC22-E. D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC22.1-E.D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC36.1-E.D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC50-E. D (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXC64-U (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30.016), Desigo PXM20-E (Todas las versiones posteriores o iguales V2.3 y anteriores a V6.30. 016), Nucleus NET (Todas las versiones), Nucleus ReadyStart V3 (Todas las versiones anteriores a V2017.02.4), Nucleus Source Code (Todas las versiones), TALON TC Compact (BACnet) (Todas las versiones anteriores a V3.5.4), TALON TC Modular (BACnet) (Todas las versiones anteriores a V3.5.4). Al procesar un mensaje DHCP OFFER, la aplicaci\u00f3n cliente DHCP no valida la longitud de la(s) opci\u00f3n(es) del vendedor, lo que provoca condiciones de denegaci\u00f3n de servicio. (FSMD-2021-0008)"
}
],
"id": "CVE-2021-31881",
"lastModified": "2024-11-21T06:06:25.167",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 4.2,
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-11-09T12:15:09.257",
"references": [
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
},
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"source": "productcert@siemens.com",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
CNVD-2021-89443
Vulnerability from cnvd - Published: 2021-11-20目前厂商已发布升级补丁以修复漏洞,补丁获取链接: https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf
| Name | ['Siemens Nucleus Source Code', 'Siemens Nucleus NET', 'SIEMENS Capital VSTAR', 'SIEMENS Nucleus ReadyStart V3 < 2017.02.4'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2021-31881"
}
},
"description": "Capital VSTAR\u662f\u4e00\u4e2a\u5b8c\u6574\u7684\u89e3\u51b3\u65b9\u6848\u3002Nucleus NET\u6a21\u5757\u96c6\u6210\u4e86\u4e00\u7cfb\u5217\u7b26\u5408\u6807\u51c6\u7684\u7f51\u7edc\u548c\u901a\u4fe1\u534f\u8bae\u3001\u9a71\u52a8\u7a0b\u5e8f\u548c\u5b9e\u7528\u7a0b\u5e8f\uff0c\u4ee5\u5728\u4efb\u4f55\u5d4c\u5165\u5f0f\u8bbe\u5907\u4e2d\u63d0\u4f9b\u5168\u529f\u80fd\u7684\u7f51\u7edc\u652f\u6301\u3002Nucleus RTOS\u662f\u4e00\u79cd\u57fa\u4e8e\u5fae\u5185\u6838\u7684\u5b9e\u65f6\u64cd\u4f5c\u7cfb\u7edf\u3002\n\n\u591a\u6b3eSiemens\u4ea7\u54c1\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5728\u5904\u7406DHCP OFFER\u6d88\u606f\u65f6\uff0cDHCP \u5ba2\u6237\u7aef\u5e94\u7528\u7a0b\u5e8f\u4e0d\u4f1a\u9a8c\u8bc1\u4f9b\u5e94\u5546\u9009\u9879\u7684\u957f\u5ea6\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5bfc\u81f4\u62d2\u7edd\u670d\u52a1\u6761\u4ef6\u3002",
"formalWay": "\u76ee\u524d\u5382\u5546\u5df2\u53d1\u5e03\u5347\u7ea7\u8865\u4e01\u4ee5\u4fee\u590d\u6f0f\u6d1e\uff0c\u8865\u4e01\u83b7\u53d6\u94fe\u63a5\uff1a\r\nhttps://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2021-89443",
"openTime": "2021-11-20",
"patchDescription": "Capital VSTAR\u662f\u4e00\u4e2a\u5b8c\u6574\u7684\u89e3\u51b3\u65b9\u6848\u3002Nucleus NET\u6a21\u5757\u96c6\u6210\u4e86\u4e00\u7cfb\u5217\u7b26\u5408\u6807\u51c6\u7684\u7f51\u7edc\u548c\u901a\u4fe1\u534f\u8bae\u3001\u9a71\u52a8\u7a0b\u5e8f\u548c\u5b9e\u7528\u7a0b\u5e8f\uff0c\u4ee5\u5728\u4efb\u4f55\u5d4c\u5165\u5f0f\u8bbe\u5907\u4e2d\u63d0\u4f9b\u5168\u529f\u80fd\u7684\u7f51\u7edc\u652f\u6301\u3002Nucleus RTOS\u662f\u4e00\u79cd\u57fa\u4e8e\u5fae\u5185\u6838\u7684\u5b9e\u65f6\u64cd\u4f5c\u7cfb\u7edf\u3002\r\n\r\n\u591a\u6b3eSiemens\u4ea7\u54c1\u5b58\u5728\u5b89\u5168\u6f0f\u6d1e\u3002\u8be5\u6f0f\u6d1e\u6e90\u4e8e\u5728\u5904\u7406DHCP OFFER\u6d88\u606f\u65f6\uff0cDHCP \u5ba2\u6237\u7aef\u5e94\u7528\u7a0b\u5e8f\u4e0d\u4f1a\u9a8c\u8bc1\u4f9b\u5e94\u5546\u9009\u9879\u7684\u957f\u5ea6\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u6f0f\u6d1e\u5bfc\u81f4\u62d2\u7edd\u670d\u52a1\u6761\u4ef6\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "\u591a\u6b3eSiemens\u4ea7\u54c1\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e \u7684\u8865\u4e01",
"products": {
"product": [
"Siemens Nucleus Source Code",
"Siemens Nucleus NET",
"SIEMENS Capital VSTAR",
"SIEMENS Nucleus ReadyStart V3 \u003c 2017.02.4"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
"serverity": "\u4e2d",
"submitTime": "2021-11-11",
"title": "\u591a\u6b3eSiemens\u4ea7\u54c1\u8d8a\u754c\u8bfb\u53d6\u6f0f\u6d1e"
}
CERTFR-2021-AVI-854
Vulnerability from certfr_avis - Published: 2021-11-09 - Updated: 2021-11-09
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | Capital VSTAR versions incluant les modules DNS | ||
| Siemens | N/A | Nucleus Source Code toutes versions | ||
| Siemens | N/A | Mendix Applications using Mendix 9 toutes versions antérieures à V9.6.2 | ||
| Siemens | N/A | Nucleus NET toutes versions | ||
| Siemens | N/A | SIMATIC WinCC V15 toutes versions | ||
| Siemens | N/A | SIMATIC WinCC V17 toutes versions | ||
| Siemens | N/A | SIMATIC WinCC OA V3.18 toutes versions | ||
| Siemens | N/A | NX 1980 Series toutes versions antérieures à V1984 | ||
| Siemens | N/A | APOGEE MEC (PPC) (BACnet) toutes versions | ||
| Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions | ||
| Siemens | N/A | SIMATIC WinCC V7.5 toutes versions antérieures à V7.5 SP2 Update 5 | ||
| Siemens | N/A | SIMATIC WinCC OA V3.17 toutes versions | ||
| Siemens | N/A | Climatix POL909 (AWM module) toutes versions antérieures à V11.34 | ||
| Siemens | N/A | SCALANCE W1750D toutes versions antérieures à V8.7.1.3 | ||
| Siemens | N/A | SIMATIC PCS 7 V9.0 toutes versions | ||
| Siemens | N/A | Siveillance Video DLNA Server 2021 R1 | ||
| Siemens | N/A | SIMATIC PCS 7 V9.1 toutes versions | ||
| Siemens | N/A | Mendix Applications using Mendix 7 toutes versions antérieures à V7.23.26 | ||
| Siemens | N/A | SIMATIC WinCC V7.4 toutes versions | ||
| Siemens | N/A | APOGEE PXC Modular (BACnet) toutes versions | ||
| Siemens | N/A | Nucleus Source Code versions incluant les modules DNS | ||
| Siemens | N/A | SIMATIC WinCC V16 toutes versions | ||
| Siemens | N/A | SIMATIC Information Server toutes versions >= V2019 SP1 | ||
| Siemens | N/A | SICAM 230 toutes versions | ||
| Siemens | N/A | Nucleus ReadyStart V4 toutes versions antérieures à V4.1.1 | ||
| Siemens | N/A | Mendix Applications using Mendix 8 toutes versions antérieures à V8.18.13 | ||
| Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions | ||
| Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2017.02.4 | ||
| Siemens | N/A | SIMATIC RTLS Locating Manager toutes versions antérieures à V2.12 | ||
| Siemens | N/A | Siveillance Video DLNA Server 2020 R1, 2020 R2, 2020 R3 | ||
| Siemens | N/A | Capital VSTAR toutes versions | ||
| Siemens | N/A | Siveillance Video DLNA Server 2019 R1, 2019 R2, 2019 R3 | ||
| Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2013.08 | ||
| Siemens | N/A | APOGEE MEC (PPC) (P2 Ethernet) toutes versions | ||
| Siemens | N/A | PSS(R)ODMS V12 toutes versions antérieures à V12.2.6.1 | ||
| Siemens | N/A | Nucleus ReadyStart V3 toutes versions antérieures à V2012.12 | ||
| Siemens | N/A | SENTRON powermanager V3 toutes versions | ||
| Siemens | N/A | APOGEE PXC Compact (BACnet) toutes versions | ||
| Siemens | N/A | TALON TC Compact (BACnet) toutes versions | ||
| Siemens | N/A | NX 1980 Series toutes versions antérieures à V1988 | ||
| Siemens | N/A | PSS(R)E V34 toutes versions antérieures à V34.9.1 | ||
| Siemens | N/A | APOGEE MBC (PPC) (P2 Ethernet) toutes versions | ||
| Siemens | N/A | NX 1953 Series toutes versions antérieures à V1973.3700 | ||
| Siemens | N/A | APOGEE MBC (PPC) (BACnet) toutes versions | ||
| Siemens | N/A | PSS(R)E V35 toutes versions antérieures à V35.3.2 | ||
| Siemens | N/A | SIMATIC PCS 7 V8.2 toutes versions | ||
| Siemens | N/A | TALON TC Modular (BACnet) toutes versions |
| Title | Publication Time | Tags | ||||||||||||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
||||||||||||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Capital VSTAR versions incluant les modules DNS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus Source Code toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 9 toutes versions ant\u00e9rieures \u00e0 V9.6.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus NET toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V15 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V17 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA V3.18 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "NX 1980 Series toutes versions ant\u00e9rieures \u00e0 V1984",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MEC (PPC) (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.5 toutes versions ant\u00e9rieures \u00e0 V7.5 SP2 Update 5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC OA V3.17 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Climatix POL909 (AWM module) toutes versions ant\u00e9rieures \u00e0 V11.34",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1750D toutes versions ant\u00e9rieures \u00e0 V8.7.1.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 V9.0 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video DLNA Server 2021 R1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 V9.1 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 7 toutes versions ant\u00e9rieures \u00e0 V7.23.26",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V7.4 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus Source Code versions incluant les modules DNS",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC WinCC V16 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC Information Server toutes versions \u003e= V2019 SP1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SICAM 230 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus ReadyStart V4 toutes versions ant\u00e9rieures \u00e0 V4.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Applications using Mendix 8 toutes versions ant\u00e9rieures \u00e0 V8.18.13",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2017.02.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC RTLS Locating Manager toutes versions ant\u00e9rieures \u00e0 V2.12",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video DLNA Server 2020 R1, 2020 R2, 2020 R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Capital VSTAR toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Video DLNA Server 2019 R1, 2019 R2, 2019 R3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2013.08",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MEC (PPC) (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)ODMS V12 toutes versions ant\u00e9rieures \u00e0 V12.2.6.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Nucleus ReadyStart V3 toutes versions ant\u00e9rieures \u00e0 V2012.12",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SENTRON powermanager V3 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TALON TC Compact (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "NX 1980 Series toutes versions ant\u00e9rieures \u00e0 V1988",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)E V34 toutes versions ant\u00e9rieures \u00e0 V34.9.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MBC (PPC) (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "NX 1953 Series toutes versions ant\u00e9rieures \u00e0 V1973.3700",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MBC (PPC) (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "PSS(R)E V35 toutes versions ant\u00e9rieures \u00e0 V35.3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS 7 V8.2 toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TALON TC Modular (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2020-27009",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27009"
},
{
"name": "CVE-2021-31881",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31881"
},
{
"name": "CVE-2020-28388",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-28388"
},
{
"name": "CVE-2021-42026",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42026"
},
{
"name": "CVE-2021-37734",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37734"
},
{
"name": "CVE-2021-42025",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42025"
},
{
"name": "CVE-2021-37732",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37732"
},
{
"name": "CVE-2021-31888",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31888"
},
{
"name": "CVE-2020-27736",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27736"
},
{
"name": "CVE-2021-31885",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31885"
},
{
"name": "CVE-2021-31887",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31887"
},
{
"name": "CVE-2020-10053",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10053"
},
{
"name": "CVE-2021-37735",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37735"
},
{
"name": "CVE-2021-41533",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41533"
},
{
"name": "CVE-2021-25663",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25663"
},
{
"name": "CVE-2021-31884",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31884"
},
{
"name": "CVE-2021-42015",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42015"
},
{
"name": "CVE-2021-40366",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40366"
},
{
"name": "CVE-2020-15795",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-15795"
},
{
"name": "CVE-2021-31882",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31882"
},
{
"name": "CVE-2021-25664",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25664"
},
{
"name": "CVE-2021-41057",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41057"
},
{
"name": "CVE-2021-37207",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37207"
},
{
"name": "CVE-2021-40358",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40358"
},
{
"name": "CVE-2020-10052",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10052"
},
{
"name": "CVE-2021-37726",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37726"
},
{
"name": "CVE-2020-10054",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-10054"
},
{
"name": "CVE-2021-41535",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41535"
},
{
"name": "CVE-2021-37727",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37727"
},
{
"name": "CVE-2021-27393",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-27393"
},
{
"name": "CVE-2021-31346",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31346"
},
{
"name": "CVE-2021-40364",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40364"
},
{
"name": "CVE-2020-27738",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27738"
},
{
"name": "CVE-2021-31889",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31889"
},
{
"name": "CVE-2021-42021",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42021"
},
{
"name": "CVE-2021-31883",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31883"
},
{
"name": "CVE-2021-41538",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41538"
},
{
"name": "CVE-2021-40359",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-40359"
},
{
"name": "CVE-2021-31886",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31886"
},
{
"name": "CVE-2021-41534",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41534"
},
{
"name": "CVE-2021-31890",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31890"
},
{
"name": "CVE-2021-37730",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-37730"
},
{
"name": "CVE-2021-31345",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31345"
},
{
"name": "CVE-2020-27737",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-27737"
},
{
"name": "CVE-2021-31344",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31344"
},
{
"name": "CVE-2021-25677",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-25677"
}
],
"initial_release_date": "2021-11-09T00:00:00",
"last_revision_date": "2021-11-09T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-854",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-11-09T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service \u00e0\ndistance et un contournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-248289 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-248289.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-703715 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-703715.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-840188 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-840188.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-362164 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-362164.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-044112 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-328042 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-328042.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-917476 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-917476.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-114589 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-201384 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-201384.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-537983 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-537983.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-779699 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-779699.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-580693 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-580693.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-185699 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-185699.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-740908 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-740908.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-145157 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-145157.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-338732 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-338732.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-755517 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-755517.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-705111 du 9 novembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-705111.pdf"
}
]
}
CERTFR-2021-AVI-949
Vulnerability from certfr_avis - Published: 2021-12-15 - Updated: 2021-12-15
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | Teamcenter Active Workspace versions 5.2.x antérieures à 5.2.3 | ||
| Siemens | N/A | JTTK versions antérieures à 11.0.3.0 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.76 | ||
| Siemens | N/A | SINUMERIK Edge versions antérieures à 3.2 | ||
| Siemens | N/A | SIMATIC ITC2200 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) versions antérieures à 21.00 SP3 | ||
| Siemens | N/A | Siveillance Identity V5 versions antérieures à 1.6.284, ou sans le correctif de sécurité SP5 | ||
| Siemens | N/A | Desigo PXC00-U toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SIMATIC ITC1900 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | JT2Go versions antérieures à 13.2.0.5 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | Desigo PXC22.1-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Desigo PXC001-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | JTTK versions antérieures à 10.8.1.1 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | APOGEE MEC (PPC) (BACnet) toutes versions | ||
| Siemens | N/A | Siveillance Identity V1.6 versions antérieures à 1.6.284.0 | ||
| Siemens | N/A | APOGEE PXC Compact (P2 Ethernet) toutes versions | ||
| Siemens | N/A | JTTK versions antérieures à 11.1.1.0 | ||
| Siemens | N/A | JT Utilities versions antérieures à 12.8.1.1 | ||
| Siemens | N/A | Desigo PXC50-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Desigo PXC200-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Desigo PXC36.1-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Desigo PXC00-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.80 | ||
| Siemens | N/A | APOGEE PXC Modular (BACnet) toutes versions | ||
| Siemens | N/A | Teamcenter Visualization versions antérieures à 13.2.0.5 | ||
| Siemens | N/A | Desigo PXC22-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Simcenter STAR-CCM+ Viewer versions antérieures à 2021.3.1 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 5.1.x antérieures à 5.1.6 | ||
| Siemens | N/A | Capital VSTAR toutes versions avec l'option Ethernet activée | ||
| Siemens | N/A | SiPass integrated versions antérieures à 2.85 | ||
| Siemens | N/A | JT Utilities versions antérieures à 13.1.1.0 | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | Desigo PXC100-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | ModelSim Simulation toutes versions | ||
| Siemens | N/A | APOGEE PXC Modular (P2 Ethernet) toutes versions | ||
| Siemens | N/A | SIMATIC ITC2200 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | Desigo PXC12-E.D toutes versions postérieures à 2.3 | ||
| Siemens | N/A | Questa Simulation toutes versions | ||
| Siemens | N/A | JT Utilities versions antérieures à 13.0.3.0 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 5.0.x antérieures à 5.0.10 | ||
| Siemens | N/A | Desigo PXC128-U toutes versions postérieures à 2.3 | ||
| Siemens | N/A | APOGEE MEC (PPC) (P2 Ethernet) toutes versions | ||
| Siemens | N/A | SIMATIC ITC1900 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | Teamcenter Active Workspace versions 4.3.x antérieures à V4.3.11 | ||
| Siemens | N/A | APOGEE PXC Compact (BACnet) toutes versions | ||
| Siemens | N/A | POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions antérieures à 2.41 | ||
| Siemens | N/A | APOGEE MBC (PPC) (P2 Ethernet) toutes versions | ||
| Siemens | N/A | APOGEE MBC (PPC) (BACnet) toutes versions | ||
| Siemens | N/A | SIMATIC ITC1500 V3 PRO versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | SIMATIC ITC1500 V3 versions antérieures à 3.2.1.0 | ||
| Siemens | N/A | Desigo PXC64-U toutes versions postérieures à 2.3 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "Teamcenter Active Workspace versions 5.2.x ant\u00e9rieures \u00e0 5.2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 11.0.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.76",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINUMERIK Edge versions ant\u00e9rieures \u00e0 3.2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC2200 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC eaSie PCS 7 Skill Package (6DL5424-0BX00-0AV8) versions ant\u00e9rieures \u00e0 21.00 SP3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Identity V5 versions ant\u00e9rieures \u00e0 1.6.284, ou sans le correctif de s\u00e9curit\u00e9 SP5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC00-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1900 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT2Go versions ant\u00e9rieures \u00e0 13.2.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA01-0AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC22.1-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC001-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 10.8.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA31-0AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MEC (PPC) (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siveillance Identity V1.6 versions ant\u00e9rieures \u00e0 1.6.284.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JTTK versions ant\u00e9rieures \u00e0 11.1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 12.8.1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC50-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC200-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC36.1-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC00-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.80",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Visualization versions ant\u00e9rieures \u00e0 13.2.0.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC22-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter STAR-CCM+ Viewer versions ant\u00e9rieures \u00e0 2021.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 5.1.x ant\u00e9rieures \u00e0 5.1.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Capital VSTAR toutes versions avec l\u0027option Ethernet activ\u00e9e",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated versions ant\u00e9rieures \u00e0 2.85",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 13.1.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA31-2AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC100-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "ModelSim Simulation toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Modular (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC2200 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC12-E.D toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Questa Simulation toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 13.0.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 5.0.x ant\u00e9rieures \u00e0 5.0.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC128-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MEC (PPC) (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1900 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Teamcenter Active Workspace versions 4.3.x ant\u00e9rieures \u00e0 V4.3.11",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE PXC Compact (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "POWER METER SICAM Q100 (7KG9501-0AA01-2AA1) versions ant\u00e9rieures \u00e0 2.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MBC (PPC) (P2 Ethernet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "APOGEE MBC (PPC) (BACnet) toutes versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1500 V3 PRO versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC ITC1500 V3 versions ant\u00e9rieures \u00e0 3.2.1.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo PXC64-U toutes versions post\u00e9rieures \u00e0 2.3",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2021-44443",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44443"
},
{
"name": "CVE-2021-31881",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31881"
},
{
"name": "CVE-2021-44444",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44444"
},
{
"name": "CVE-2021-44009",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44009"
},
{
"name": "CVE-2021-31888",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31888"
},
{
"name": "CVE-2021-44447",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44447"
},
{
"name": "CVE-2018-20749",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20749"
},
{
"name": "CVE-2021-44013",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44013"
},
{
"name": "CVE-2021-31885",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31885"
},
{
"name": "CVE-2021-31887",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31887"
},
{
"name": "CVE-2019-15690",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-15690"
},
{
"name": "CVE-2021-44012",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44012"
},
{
"name": "CVE-2020-14396",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14396"
},
{
"name": "CVE-2021-44001",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44001"
},
{
"name": "CVE-2020-14404",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14404"
},
{
"name": "CVE-2021-44430",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44430"
},
{
"name": "CVE-2021-44440",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44440"
},
{
"name": "CVE-2021-44432",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44432"
},
{
"name": "CVE-2021-44445",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44445"
},
{
"name": "CVE-2021-31884",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31884"
},
{
"name": "CVE-2021-44434",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44434"
},
{
"name": "CVE-2021-44449",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44449"
},
{
"name": "CVE-2019-15681",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-15681"
},
{
"name": "CVE-2021-44435",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44435"
},
{
"name": "CVE-2021-42023",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42023"
},
{
"name": "CVE-2021-44442",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44442"
},
{
"name": "CVE-2021-44002",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44002"
},
{
"name": "CVE-2021-44014",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44014"
},
{
"name": "CVE-2021-44436",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44436"
},
{
"name": "CVE-2021-31882",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31882"
},
{
"name": "CVE-2021-44438",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44438"
},
{
"name": "CVE-2021-44006",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44006"
},
{
"name": "CVE-2021-41547",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41547"
},
{
"name": "CVE-2021-44008",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44008"
},
{
"name": "CVE-2021-44017",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44017"
},
{
"name": "CVE-2021-44441",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44441"
},
{
"name": "CVE-2021-44011",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44011"
},
{
"name": "CVE-2018-20748",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20748"
},
{
"name": "CVE-2019-20788",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20788"
},
{
"name": "CVE-2021-44446",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44446"
},
{
"name": "CVE-2021-44010",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44010"
},
{
"name": "CVE-2021-44522",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44522"
},
{
"name": "CVE-2021-44448",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44448"
},
{
"name": "CVE-2021-44523",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44523"
},
{
"name": "CVE-2019-20840",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20840"
},
{
"name": "CVE-2021-31346",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31346"
},
{
"name": "CVE-2018-20750",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20750"
},
{
"name": "CVE-2021-42022",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42022"
},
{
"name": "CVE-2021-44433",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44433"
},
{
"name": "CVE-2021-44004",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44004"
},
{
"name": "CVE-2017-18922",
"url": "https://www.cve.org/CVERecord?id=CVE-2017-18922"
},
{
"name": "CVE-2021-44524",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44524"
},
{
"name": "CVE-2021-44003",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44003"
},
{
"name": "CVE-2021-44007",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44007"
},
{
"name": "CVE-2021-42024",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42024"
},
{
"name": "CVE-2019-20839",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-20839"
},
{
"name": "CVE-2021-44431",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44431"
},
{
"name": "CVE-2021-31889",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31889"
},
{
"name": "CVE-2021-44005",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44005"
},
{
"name": "CVE-2020-14402",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14402"
},
{
"name": "CVE-2020-14397",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14397"
},
{
"name": "CVE-2021-31883",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31883"
},
{
"name": "CVE-2020-14398",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14398"
},
{
"name": "CVE-2020-14403",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14403"
},
{
"name": "CVE-2021-44439",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44439"
},
{
"name": "CVE-2021-44015",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44015"
},
{
"name": "CVE-2021-44437",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44437"
},
{
"name": "CVE-2021-31886",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31886"
},
{
"name": "CVE-2021-44450",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44450"
},
{
"name": "CVE-2021-42027",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-42027"
},
{
"name": "CVE-2021-31890",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31890"
},
{
"name": "CVE-2020-14405",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14405"
},
{
"name": "CVE-2021-31345",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31345"
},
{
"name": "CVE-2018-20019",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-20019"
},
{
"name": "CVE-2018-15127",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-15127"
},
{
"name": "CVE-2018-21247",
"url": "https://www.cve.org/CVERecord?id=CVE-2018-21247"
},
{
"name": "CVE-2021-44165",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44165"
},
{
"name": "CVE-2021-31344",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-31344"
},
{
"name": "CVE-2020-14401",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-14401"
}
],
"initial_release_date": "2021-12-15T00:00:00",
"last_revision_date": "2021-12-15T00:00:00",
"links": [],
"reference": "CERTFR-2021-AVI-949",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2021-12-15T00:00:00.000000"
}
],
"risks": [
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "D\u00e9ni de service"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans les produits\nSiemens. Certaines d\u0027entre elles permettent \u00e0 un attaquant de provoquer\nune ex\u00e9cution de code arbitraire \u00e0 distance, un d\u00e9ni de service et un\ncontournement de la politique de s\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-620288 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-133772 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-133772.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-199605 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-199605.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-595101 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-595101.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-496292 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-496292.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-400332 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-400332.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-463116 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-463116.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-523250 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-523250.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-352143 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-352143.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-390195 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-390195.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-396621 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-396621.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-802578 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-802578.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-160202 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-160202.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-161331 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-161331.pdf"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens ssa-114589 du 14 d\u00e9cembre 2021",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
}
]
}
GHSA-X327-PX9P-WGR2
Vulnerability from github – Published: 2022-05-24 19:20 – Updated: 2024-10-08 09:30A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Capital VSTAR (All versions), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions < V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)
{
"affected": [],
"aliases": [
"CVE-2021-31881"
],
"database_specific": {
"cwe_ids": [
"CWE-125"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2021-11-09T12:15:00Z",
"severity": "HIGH"
},
"details": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Capital VSTAR (All versions), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)",
"id": "GHSA-x327-px9p-wgr2",
"modified": "2024-10-08T09:30:50Z",
"published": "2022-05-24T19:20:11Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2021-31881"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-044112.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-114589.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-620288.html"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"type": "WEB",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"type": "CVSS_V3"
}
]
}
GSD-2021-31881
Vulnerability from gsd - Updated: 2023-12-13 01:23{
"GSD": {
"alias": "CVE-2021-31881",
"description": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions), APOGEE PXC Compact (P2 Ethernet) (All versions), APOGEE PXC Modular (BACnet) (All versions), APOGEE PXC Modular (P2 Ethernet) (All versions), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3), Desigo PXC00-U (All versions \u003e= V2.3), Desigo PXC001-E.D (All versions \u003e= V2.3), Desigo PXC100-E.D (All versions \u003e= V2.3), Desigo PXC12-E.D (All versions \u003e= V2.3), Desigo PXC128-U (All versions \u003e= V2.3), Desigo PXC200-E.D (All versions \u003e= V2.3), Desigo PXC22-E.D (All versions \u003e= V2.3), Desigo PXC22.1-E.D (All versions \u003e= V2.3), Desigo PXC36.1-E.D (All versions \u003e= V2.3), Desigo PXC50-E.D (All versions \u003e= V2.3), Desigo PXC64-U (All versions \u003e= V2.3), Desigo PXM20-E (All versions \u003e= V2.3), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions), TALON TC Modular (BACnet) (All versions). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)",
"id": "GSD-2021-31881"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2021-31881"
],
"details": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)",
"id": "GSD-2021-31881",
"modified": "2023-12-13T01:23:13.025820Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-31881",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "APOGEE MBC (PPC) (BACnet)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "APOGEE MBC (PPC) (P2 Ethernet)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "APOGEE MEC (PPC) (BACnet)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "APOGEE MEC (PPC) (P2 Ethernet)",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "APOGEE PXC Compact (BACnet)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.5.4"
}
]
}
},
{
"product_name": "APOGEE PXC Compact (P2 Ethernet)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.8.19"
}
]
}
},
{
"product_name": "APOGEE PXC Modular (BACnet)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.5.4"
}
]
}
},
{
"product_name": "APOGEE PXC Modular (P2 Ethernet)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2.8.19"
}
]
}
},
{
"product_name": "Capital VSTAR",
"version": {
"version_data": [
{
"version_value": "All versions with enabled Ethernet options"
}
]
}
},
{
"product_name": "Desigo PXC00-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC00-U",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC001-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC100-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC12-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC128-U",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC200-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC22-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC22.1-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC36.1-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC50-E.D",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXC64-U",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Desigo PXM20-E",
"version": {
"version_data": [
{
"version_value": "All versions \u003e= V2.3 and \u003c V6.30.016"
}
]
}
},
{
"product_name": "Nucleus NET",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "Nucleus ReadyStart V3",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V2017.02.4"
}
]
}
},
{
"product_name": "Nucleus Source Code",
"version": {
"version_data": [
{
"version_value": "All versions"
}
]
}
},
{
"product_name": "TALON TC Compact (BACnet)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.5.4"
}
]
}
},
{
"product_name": "TALON TC Modular (BACnet)",
"version": {
"version_data": [
{
"version_value": "All versions \u003c V3.5.4"
}
]
}
}
]
},
"vendor_name": "Siemens"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-125: Out-of-bounds Read"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf",
"refsource": "MISC",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:siemens:nucleus_source_code:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:nucleus_net:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:capital_vstar:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
},
{
"cpe23Uri": "cpe:2.3:a:siemens:nucleus_readystart_v3:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2012.08",
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:apogee_modular_building_controller_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:apogee_modular_building_controller:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:apogee_modular_equiment_controller_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:apogee_modular_equiment_controller:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:apogee_pxc_compact_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:apogee_pxc_compact:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:apogee_pxc_modular_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:apogee_pxc_modular:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:talon_tc_compact_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:talon_tc_compact:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
},
{
"children": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:o:siemens:talon_tc_modular_firmware:*:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": true
}
],
"operator": "OR"
},
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:h:siemens:talon_tc_modular:-:*:*:*:*:*:*:*",
"cpe_name": [],
"vulnerable": false
}
],
"operator": "OR"
}
],
"cpe_match": [],
"operator": "AND"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "productcert@siemens.com",
"ID": "CVE-2021-31881"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A vulnerability has been identified in APOGEE MBC (PPC) (BACnet) (All versions), APOGEE MBC (PPC) (P2 Ethernet) (All versions), APOGEE MEC (PPC) (BACnet) (All versions), APOGEE MEC (PPC) (P2 Ethernet) (All versions), APOGEE PXC Compact (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Compact (P2 Ethernet) (All versions \u003c V2.8.19), APOGEE PXC Modular (BACnet) (All versions \u003c V3.5.4), APOGEE PXC Modular (P2 Ethernet) (All versions \u003c V2.8.19), Capital VSTAR (All versions with enabled Ethernet options), Desigo PXC00-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC00-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC001-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC100-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC12-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC128-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC200-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC22.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC36.1-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC50-E.D (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXC64-U (All versions \u003e= V2.3 and \u003c V6.30.016), Desigo PXM20-E (All versions \u003e= V2.3 and \u003c V6.30.016), Nucleus NET (All versions), Nucleus ReadyStart V3 (All versions \u003c V2017.02.4), Nucleus Source Code (All versions), TALON TC Compact (BACnet) (All versions \u003c V3.5.4), TALON TC Modular (BACnet) (All versions \u003c V3.5.4). When processing a DHCP OFFER message, the DHCP client application does not validate the length of the Vendor option(s), leading to Denial-of-Service conditions. (FSMD-2021-0008)"
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-125"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-044112.pdf"
},
{
"name": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-114589.pdf"
},
{
"name": "N/A",
"refsource": "CONFIRM",
"tags": [],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-620288.pdf"
}
]
}
},
"impact": {
"baseMetricV2": {
"acInsufInfo": false,
"cvssV2": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"severity": "MEDIUM",
"userInteractionRequired": false
},
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6
}
},
"lastModifiedDate": "2022-05-20T13:15Z",
"publishedDate": "2021-11-09T12:15Z"
}
}
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.