CVE-2022-2272 (GCVE-0-2022-2272)
Vulnerability from cvelistv5 – Published: 2022-08-03 15:20 – Updated: 2024-08-03 00:32
VLAI?
Summary
This vulnerability allows remote attackers to bypass authentication on affected installations of Sante PACS Server 3.0.4. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of calls to the login endpoint. When parsing the username element, the process does not properly validate a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17331.
Severity ?
9.8 (Critical)
CWE
- CWE-89 - Improper Neutralization of Special Elements used in an SQL Command ('SQL Injection')
Assigner
References
| URL | Tags | ||||
|---|---|---|---|---|---|
|
|||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Sante | PACS Server |
Affected:
3.0.4
|
Credits
Florent Saudel
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-03T00:32:09.547Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_refsource_MISC",
"x_transferred"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-955/"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"product": "PACS Server",
"vendor": "Sante",
"versions": [
{
"status": "affected",
"version": "3.0.4"
}
]
}
],
"credits": [
{
"lang": "en",
"value": "Florent Saudel"
}
],
"descriptions": [
{
"lang": "en",
"value": "This vulnerability allows remote attackers to bypass authentication on affected installations of Sante PACS Server 3.0.4. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of calls to the login endpoint. When parsing the username element, the process does not properly validate a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17331."
}
],
"metrics": [
{
"cvssV3_0": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-89",
"description": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2022-08-03T15:20:59",
"orgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"shortName": "zdi"
},
"references": [
{
"tags": [
"x_refsource_MISC"
],
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-955/"
}
],
"x_legacyV4Record": {
"CVE_data_meta": {
"ASSIGNER": "zdi-disclosures@trendmicro.com",
"ID": "CVE-2022-2272",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "PACS Server",
"version": {
"version_data": [
{
"version_value": "3.0.4"
}
]
}
}
]
},
"vendor_name": "Sante"
}
]
}
},
"credit": "Florent Saudel",
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "This vulnerability allows remote attackers to bypass authentication on affected installations of Sante PACS Server 3.0.4. Authentication is not required to exploit this vulnerability. The specific flaw exists within the processing of calls to the login endpoint. When parsing the username element, the process does not properly validate a user-supplied string before using it to construct SQL queries. An attacker can leverage this vulnerability to bypass authentication on the system. Was ZDI-CAN-17331."
}
]
},
"impact": {
"cvss": {
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.0"
}
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "CWE-89: Improper Neutralization of Special Elements used in an SQL Command (\u0027SQL Injection\u0027)"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.zerodayinitiative.com/advisories/ZDI-22-955/",
"refsource": "MISC",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-22-955/"
}
]
}
}
}
},
"cveMetadata": {
"assignerOrgId": "99f1926a-a320-47d8-bbb5-42feb611262e",
"assignerShortName": "zdi",
"cveId": "CVE-2022-2272",
"datePublished": "2022-08-03T15:20:59",
"dateReserved": "2022-06-30T00:00:00",
"dateUpdated": "2024-08-03T00:32:09.547Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…