Action not permitted
Modal body text goes here.
Modal Title
Modal Body
CVE-2023-22670 (GCVE-0-2023-22670)
Vulnerability from cvelistv5 – Published: 2023-04-15 00:00 – Updated: 2025-05-05 16:05- n/a
{
"containers": {
"adp": [
{
"providerMetadata": {
"dateUpdated": "2024-08-02T10:13:49.972Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://www.opendesign.com/security-advisories"
}
],
"title": "CVE Program Container"
},
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2023-22670",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-04-23T13:28:37.328547Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-787",
"description": "CWE-787 Out-of-bounds Write",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-05-05T16:05:49.043Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2023-04-15T00:00:00.000Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.opendesign.com/security-advisories"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2023-22670",
"datePublished": "2023-04-15T00:00:00.000Z",
"dateReserved": "2023-01-06T00:00:00.000Z",
"dateUpdated": "2025-05-05T16:05:49.043Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.opendesign.com/security-advisories\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T10:13:49.972Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-22670\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-04-23T13:28:37.328547Z\"}}}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-787\", \"description\": \"CWE-787 Out-of-bounds Write\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-05-05T13:05:58.090Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://www.opendesign.com/security-advisories\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2023-04-15T00:00:00.000Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2023-22670\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-05-05T16:05:49.043Z\", \"dateReserved\": \"2023-01-06T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2023-04-15T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
CERTFR-2023-AVI-0121
Vulnerability from certfr_avis - Published: 2023-02-14 - Updated: 2023-02-14
De multiples vulnérabilités ont été corrigées dans les produits Siemens. Elles permettent à un attaquant de provoquer une exécution de code arbitraire à distance, un déni de service à distance et un contournement de la politique de sécurité.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | JT Utilities versions antérieures à V13.2.3.0 | ||
| Siemens | N/A | Parasolid V35.0 versions antérieures à V35.0.170 | ||
| Siemens | N/A | TIA Project-Server versions antérieures à V1.1 | ||
| Siemens | N/A | COMOS V10.3.3.4 versions antérieures à V10.3.3.4.6 | ||
| Siemens | N/A | SCALANCE X204IRT (6GK5204-0BA00-2BA3) versions antérieures à V5.5.0 | ||
| Siemens | N/A | Parasolid V34.1 versions antérieures à V34.1.242 | ||
| Siemens | N/A | TIA Multiuser Server V16 toutes les versions | ||
| Siemens | N/A | COMOS V10.2 toutes les versions | ||
| Siemens | N/A | Simcenter Femap versions antérieures à V2023.1 | ||
| Siemens | N/A | Applications utilisant Mendix versions 9 (V9.12) antérieures à V9.12.10 | ||
| Siemens | N/A | Parasolid V35.1 versions antérieures à V35.1.150 | ||
| Siemens | N/A | COMOS V10.3.3.3 versions antérieures à V10.3.3.3.9 | ||
| Siemens | N/A | SCALANCE XF204IRT (6GK5204-0BA00-2BF2) versions antérieures à V5.5.0 | ||
| Siemens | N/A | Brownfield Connectivity - Client versions antérieures à V2.15 | ||
| Siemens | N/A | COMOS V10.4.2.0 versions antérieures à V10.4.2.0.25 | ||
| Siemens | N/A | TIA Multiuser Server V14 toutes les versions | ||
| Siemens | N/A | COMOS V10.3.3.1 versions antérieures à V10.3.3.1.45 | ||
| Siemens | N/A | Parasolid V34.0 versions antérieures à V34.0.254 | ||
| Siemens | N/A | SiPass integrated AC5102 (ACC-G2) versions antérieures à V2.85.44 | ||
| Siemens | N/A | Solid Edge SE2023 versions antérieures à V2023Update2 | ||
| Siemens | N/A | SiPass integrated ACC-AP versions antérieures à V2.85.43 | ||
| Siemens | N/A | SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) versions antérieures à V5.5.0 | ||
| Siemens | N/A | COMOS V10.4.0.0 versions antérieures à V10.4.0.0.31 | ||
| Siemens | N/A | Applications utilisant Mendix versions 7 antérieures à V7.23.34 | ||
| Siemens | N/A | Applications utilisant Mendix versions 9 (V9.18) antérieures à V9.18.4 | ||
| Siemens | N/A | SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) versions antérieures à V5.5.0 | ||
| Siemens | N/A | SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) versions antérieures à V5.5.0 | ||
| Siemens | N/A | SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3) versions antérieures à V5.5.0 | ||
| Siemens | N/A | SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2) versions antérieures à V5.5.0 | ||
| Siemens | N/A | TIA Multiuser Server V15 versions antérieures à V15.1 Update 8 | ||
| Siemens | N/A | SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6) versions antérieures à V5.5.0 | ||
| Siemens | N/A | SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) versions antérieures à V5.5.0 | ||
| Siemens | N/A | Applications utilisant Mendix versions 8 antérieures à V8.18.23 | ||
| Siemens | N/A | Famille de produits SIMATIC Field PG, SIMATIC IPC et SIMATIC ITP toutes les versions | ||
| Siemens | N/A | SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) versions antérieures à V5.5.0 | ||
| Siemens | N/A | Brownfield Connectivity - Gateway versions antérieures à V1.11 | ||
| Siemens | N/A | SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) versions antérieures à V5.5.0 | ||
| Siemens | N/A | TIA Multiuser Server V17 toutes les versions | ||
| Siemens | N/A | Famille de produits RUGGEDCOM APE1808 toutes les versions | ||
| Siemens | N/A | SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) versions antérieures à V5.5.0 | ||
| Siemens | N/A | Applications utilisant Mendix versions 9 (V9.6) antérieures à V9.6.15 | ||
| Siemens | N/A | COMOS V10.4.1.0 versions antérieures à V10.4.1.0.32 | ||
| Siemens | N/A | SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2) versions antérieures à V5.5.0 | ||
| Siemens | N/A | COMOS V10.3.3.2 versions antérieures à V10.3.3.2.33 | ||
| Siemens | N/A | Tecnomatix Plant Simulation versions antérieures à V2201.0006 | ||
| Siemens | N/A | JT Open versions antérieures à V11.2.3.0 | ||
| Siemens | N/A | Applications utilisant Mendix versions 9 antérieures à V9.22.0 |
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "JT Utilities versions ant\u00e9rieures \u00e0 V13.2.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid V35.0 versions ant\u00e9rieures \u00e0 V35.0.170",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Project-Server versions ant\u00e9rieures \u00e0 V1.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS V10.3.3.4 versions ant\u00e9rieures \u00e0 V10.3.3.4.6",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X204IRT (6GK5204-0BA00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid V34.1 versions ant\u00e9rieures \u00e0 V34.1.242",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Multiuser Server V16 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS V10.2 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter Femap versions ant\u00e9rieures \u00e0 V2023.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications utilisant Mendix versions 9 (V9.12) ant\u00e9rieures \u00e0 V9.12.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid V35.1 versions ant\u00e9rieures \u00e0 V35.1.150",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS V10.3.3.3 versions ant\u00e9rieures \u00e0 V10.3.3.3.9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204IRT (6GK5204-0BA00-2BF2) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Brownfield Connectivity - Client versions ant\u00e9rieures \u00e0 V2.15",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS V10.4.2.0 versions ant\u00e9rieures \u00e0 V10.4.2.0.25",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Multiuser Server V14 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS V10.3.3.1 versions ant\u00e9rieures \u00e0 V10.3.3.1.45",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Parasolid V34.0 versions ant\u00e9rieures \u00e0 V34.0.254",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated AC5102 (ACC-G2) versions ant\u00e9rieures \u00e0 V2.85.44",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Solid Edge SE2023 versions ant\u00e9rieures \u00e0 V2023Update2",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SiPass integrated ACC-AP versions ant\u00e9rieures \u00e0 V2.85.43",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204-2BA IRT (6GK5204-2AA00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS V10.4.0.0 versions ant\u00e9rieures \u00e0 V10.4.0.0.31",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications utilisant Mendix versions 7 ant\u00e9rieures \u00e0 V7.23.34",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications utilisant Mendix versions 9 (V9.18) ant\u00e9rieures \u00e0 V9.18.4",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X202-2P IRT PRO (6GK5202-2JR00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X204IRT PRO (6GK5204-0JA00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE X202-2P IRT (6AG1202-2BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF201-3P IRT (6GK5201-3BH00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Multiuser Server V15 versions ant\u00e9rieures \u00e0 V15.1 Update 8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X201-3P IRT PRO (6GK5201-3JR00-2BA6) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X202-2IRT (6GK5202-2BB00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications utilisant Mendix versions 8 ant\u00e9rieures \u00e0 V8.18.23",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Famille de produits SIMATIC Field PG, SIMATIC IPC et SIMATIC ITP toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X200-4P IRT (6GK5200-4AH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Brownfield Connectivity - Gateway versions ant\u00e9rieures \u00e0 V1.11",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X201-3P IRT (6GK5201-3BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "TIA Multiuser Server V17 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Famille de produits RUGGEDCOM APE1808 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE X202-2P IRT (6GK5202-2BH00-2BA3) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications utilisant Mendix versions 9 (V9.6) ant\u00e9rieures \u00e0 V9.6.15",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS V10.4.1.0 versions ant\u00e9rieures \u00e0 V10.4.1.0.32",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF202-2P IRT (6GK5202-2BH00-2BD2) versions ant\u00e9rieures \u00e0 V5.5.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS V10.3.3.2 versions ant\u00e9rieures \u00e0 V10.3.3.2.33",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation versions ant\u00e9rieures \u00e0 V2201.0006",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "JT Open versions ant\u00e9rieures \u00e0 V11.2.3.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications utilisant Mendix versions 9 ant\u00e9rieures \u00e0 V9.22.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-24556",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24556"
},
{
"name": "CVE-2022-1343",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1343"
},
{
"name": "CVE-2022-1473",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1473"
},
{
"name": "CVE-2023-24990",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24990"
},
{
"name": "CVE-2022-39157",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39157"
},
{
"name": "CVE-2022-46345",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46345"
},
{
"name": "CVE-2023-22669",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22669"
},
{
"name": "CVE-2023-24549",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24549"
},
{
"name": "CVE-2023-24560",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24560"
},
{
"name": "CVE-2022-31808",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31808"
},
{
"name": "CVE-2022-46347",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46347"
},
{
"name": "CVE-2022-27536",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-27536"
},
{
"name": "CVE-2022-46349",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46349"
},
{
"name": "CVE-2022-24921",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24921"
},
{
"name": "CVE-2022-28327",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28327"
},
{
"name": "CVE-2022-1292",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1292"
},
{
"name": "CVE-2023-24552",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24552"
},
{
"name": "CVE-2021-43391",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-43391"
},
{
"name": "CVE-2023-24980",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24980"
},
{
"name": "CVE-2021-32936",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32936"
},
{
"name": "CVE-2022-33984",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-33984"
},
{
"name": "CVE-2023-24551",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24551"
},
{
"name": "CVE-2022-46346",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46346"
},
{
"name": "CVE-2023-24992",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24992"
},
{
"name": "CVE-2022-21198",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-21198"
},
{
"name": "CVE-2007-5846",
"url": "https://www.cve.org/CVERecord?id=CVE-2007-5846"
},
{
"name": "CVE-2022-33906",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-33906"
},
{
"name": "CVE-2023-24562",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24562"
},
{
"name": "CVE-2023-24482",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24482"
},
{
"name": "CVE-2023-24994",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24994"
},
{
"name": "CVE-2021-41771",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41771"
},
{
"name": "CVE-2022-43397",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-43397"
},
{
"name": "CVE-2023-24561",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24561"
},
{
"name": "CVE-2023-24995",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24995"
},
{
"name": "CVE-2022-30774",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30774"
},
{
"name": "CVE-2023-24553",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24553"
},
{
"name": "CVE-2023-24984",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24984"
},
{
"name": "CVE-2021-32938",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32938"
},
{
"name": "CVE-2023-24993",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24993"
},
{
"name": "CVE-2023-24558",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24558"
},
{
"name": "CVE-2022-46348",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-46348"
},
{
"name": "CVE-2023-22295",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22295"
},
{
"name": "CVE-2021-32948",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-32948"
},
{
"name": "CVE-2022-33982",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-33982"
},
{
"name": "CVE-2023-22846",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22846"
},
{
"name": "CVE-2023-24983",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24983"
},
{
"name": "CVE-2022-47936",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47936"
},
{
"name": "CVE-2022-47977",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47977"
},
{
"name": "CVE-2023-24550",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24550"
},
{
"name": "CVE-2023-24565",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24565"
},
{
"name": "CVE-2023-25140",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-25140"
},
{
"name": "CVE-2023-24988",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24988"
},
{
"name": "CVE-2022-35868",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-35868"
},
{
"name": "CVE-2023-24554",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24554"
},
{
"name": "CVE-2022-33907",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-33907"
},
{
"name": "CVE-2021-43336",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-43336"
},
{
"name": "CVE-2023-24581",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24581"
},
{
"name": "CVE-2023-22321",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22321"
},
{
"name": "CVE-2022-24675",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-24675"
},
{
"name": "CVE-2023-24557",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24557"
},
{
"name": "CVE-2023-24566",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24566"
},
{
"name": "CVE-2023-24978",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24978"
},
{
"name": "CVE-2023-24555",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24555"
},
{
"name": "CVE-2023-24979",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24979"
},
{
"name": "CVE-2023-22354",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22354"
},
{
"name": "CVE-2021-41772",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-41772"
},
{
"name": "CVE-2023-24987",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24987"
},
{
"name": "CVE-2023-24986",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24986"
},
{
"name": "CVE-2021-44716",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44716"
},
{
"name": "CVE-2023-23579",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23579"
},
{
"name": "CVE-2023-24564",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24564"
},
{
"name": "CVE-2023-24982",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24982"
},
{
"name": "CVE-2023-24996",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24996"
},
{
"name": "CVE-2022-31243",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-31243"
},
{
"name": "CVE-2023-24563",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24563"
},
{
"name": "CVE-2023-24985",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24985"
},
{
"name": "CVE-2023-24991",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24991"
},
{
"name": "CVE-2023-24981",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24981"
},
{
"name": "CVE-2021-44717",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-44717"
},
{
"name": "CVE-2022-1434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-1434"
},
{
"name": "CVE-2022-33908",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-33908"
},
{
"name": "CVE-2023-23835",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-23835"
},
{
"name": "CVE-2023-24559",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24559"
},
{
"name": "CVE-2023-24989",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24989"
},
{
"name": "CVE-2023-22670",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22670"
}
],
"initial_release_date": "2023-02-14T00:00:00",
"last_revision_date": "2023-02-14T00:00:00",
"links": [
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-836777.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-953464.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-617755.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-658793.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-686975.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491245.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-744259.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-693110.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-565356.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-640968.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-847261.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-450613.pdf"
},
{
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens du 14 f\u00e9vrier 2023",
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-252808.pdf"
}
],
"reference": "CERTFR-2023-AVI-0121",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-02-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 corrig\u00e9es dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Elles permettent \u00e0 un\nattaquant de provoquer une ex\u00e9cution de code arbitraire \u00e0 distance, un\nd\u00e9ni de service \u00e0 distance et un contournement de la politique de\ns\u00e9curit\u00e9.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-847261 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-693110 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-953464 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-744259 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-617755 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-658793 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-450613 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-491245 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-686975 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-836777 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-565356 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-252808 du 14 f\u00e9vrier 2023",
"url": null
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 [SCADA] Siemens SSA-640968 du 14 f\u00e9vrier 2023",
"url": null
}
]
}
CERTFR-2023-AVI-0935
Vulnerability from certfr_avis - Published: 2023-11-14 - Updated: 2023-11-14
De multiples vulnérabilités ont été découvertes dans les produits Siemens. Certaines d'entre elles permettent à un attaquant de provoquer une élévation de privilèges, un déni de service à distance et une exécution de code arbitraire à distance.
Solution
Se référer au bulletin de sécurité de l'éditeur pour l'obtention des correctifs (cf. section Documentation).
None| Vendor | Product | Description | ||
|---|---|---|---|---|
| Siemens | N/A | RUGGEDCOM RS900F toutes les versions | ||
| Siemens | N/A | COMOS versions antérieures à V10.4.4, les vulnérabilités CVE-2023-43505, CVE-2023-46601 ne seront pas corrigées par l'éditeur | ||
| Siemens | N/A | Desigo CC product family V5.0 toutes les versions sans le dernier correctif de sécurité | ||
| Siemens | N/A | Desigo CC product family V5.1 toutes les versions sans le dernier correctif de sécurité | ||
| Siemens | N/A | Desigo CC product family V6 toutes les versions sans le dernier correctif de sécurité | ||
| Siemens | N/A | Desigo CC product family V7 toutes les versions sans le dernier correctif de sécurité | ||
| Siemens | N/A | Applications Mendix basées sur Mendix 10 versions antérieures à V10.4.0 | ||
| Siemens | N/A | Applications Mendix basées sur Mendix 7.x versions antérieures à V7.23.37 | ||
| Siemens | N/A | Applications Mendix basées sur Mendix 8.x versions antérieures à V8.18.27 | ||
| Siemens | N/A | Applications Mendix basées sur Mendix 9.x versions antérieures à V9.24.10 | ||
| Siemens | N/A | Mendix Studio Pro 10 versions antérieures à V10.3.1 | ||
| Siemens | N/A | Mendix Studio Pro 7 versions antérieures à V7.23.37 | ||
| Siemens | N/A | Mendix Studio Pro 8 versions antérieures à V8.18.27 | ||
| Siemens | N/A | Mendix Studio Pro 9 versions antérieures à V9.24.0 | ||
| Siemens | N/A | RUGGEDCOM APE1808 toutes versions utilisées avec Nozomi Guardian / CMC versions V22.6.3 à 23.1.0sans le dernier correctif de sécurité | ||
| Siemens | N/A | RUGGEDCOM M2100 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM M2100F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M2100NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M2200 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM M2200F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M2200NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M969 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM M969F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM M969NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RMC30 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RMC30NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RMC8388 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RMC8388 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RMC8388NC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RMC8388NC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RP110 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RP110NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS1600 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS1600F versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS1600FNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS1600NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS1600T versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS1600TNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS400 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS400F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS400NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS401 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS401NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS416F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416NCv2 V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416NCv2 V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416P versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS416PF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416PNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416PNCv2 V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416PNCv2 V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS416Pv2 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS416Pv2 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS416v2 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS416v2 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS8000 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS8000A versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS8000ANC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS8000H versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS8000HNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS8000NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS8000T versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS8000TNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900 (32M) V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900 (32M) V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS900 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900G (32M) V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900G (32M) V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RS900G versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900GF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900GNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900GNC(32M) V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900GNC(32M) V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900GP versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900GPF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900GPNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900L versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900LNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900M-GETS-C01 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900M-GETS-XX versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900M-STND-C01 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900M-STND-XX versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS900MNC-GETS-C01 toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900MNC-GETS-XX toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900MNC-STND-XX toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900MNC-STND-XX-C01 toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900NC(32M) V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900NC(32M) V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS900W versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS910 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS910L versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS910LNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS910NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS910W versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS920L versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS920LNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS920W versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS930L versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS930LNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS930W versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS940G versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS940GF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS940GNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RS969 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RS969NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100 (32M) V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2100 (32M) V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG2100 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2100F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100NC(32M) V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100NC(32M) V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100P versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2100PF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2100PNC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2200 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2200F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2200NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2288 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2288 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG2288NC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2288NC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2300 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG2300F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300NC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300NC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300P V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2300P V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG2300PF toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300PNC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2300PNC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2488 V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG2488 V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG2488F toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2488NC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG2488NC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG907R versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG908C versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG909R versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG910C versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG920P V4.X versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM RSG920P V5.X versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSG920PNC V4.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSG920PNC V5.X toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RSL910 versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RSL910NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM RST2228 versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RST2228P versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RST916C versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM RST916P versions antérieures à V5.6.0 | ||
| Siemens | N/A | RUGGEDCOM i800 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM i800NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM i801 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM i801NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM i802 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM i802NC toutes les versions | ||
| Siemens | N/A | RUGGEDCOM i803 versions antérieures à V4.3.8 | ||
| Siemens | N/A | RUGGEDCOM i803NC toutes les versions | ||
| Siemens | N/A | SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) toutes les versions | ||
| Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) toutes les versions | ||
| Siemens | N/A | SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) toutes les versions | ||
| Siemens | N/A | SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) toutes les versions | ||
| Siemens | N/A | SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) toutes les versions | ||
| Siemens | N/A | SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) toutes les versions | ||
| Siemens | N/A | SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) toutes les versions | ||
| Siemens | N/A | SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) toutes les versions | ||
| Siemens | N/A | SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) toutes les versions | ||
| Siemens | N/A | SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) toutes les versions | ||
| Siemens | N/A | SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208 (6GK5208-0BA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208EEC (6GK5208-0BA00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208G (6GK5208-0GA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208G EEC (6GK5208-0GA00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC208G PoE (6GK5208-0RA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216 (6GK5216-0BA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216-4C (6GK5216-4BS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216-4C G (6GK5216-4GS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC216EEC (6GK5216-0BA00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC224 (6GK5224-0BA00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC224-4C G (6GK5224-4GS00-2AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XF204 (6GK5204-0BA00-2GF2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XF204 DNA (6GK5204-0BA00-2YF2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XF204-2BA (6GK5204-2AA00-2GF2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP208 (6GK5208-0HA00-2AS6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP208EEC (6GK5208-0HA00-2ES6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP216 (6GK5216-0HA00-2AS6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP216EEC (6GK5216-0HA00-2ES6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3) versions antérieures à V4.5 | ||
| Siemens | N/A | SIMATIC MV500 family versions antérieures à V3.3.5 | ||
| Siemens | N/A | SIMATIC PCS neo versions antérieures à V4.1 | ||
| Siemens | N/A | SINEC PNI versions antérieures à V2.0 | ||
| Siemens | N/A | SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2) versions antérieures à V4.5 | ||
| Siemens | N/A | SIPROTEC 4 7SJ66 versions antérieures à V4.41 | ||
| Siemens | N/A | Siemens OPC UA Modelling Editor (SiOME) versions antérieures à V2.8 | ||
| Siemens | N/A | Simcenter Femap V2301 versions antérieures à V2301.0003 | ||
| Siemens | N/A | Simcenter Femap V2306 versions antérieures à V2306.0001 | ||
| Siemens | N/A | Tecnomatix Plant Simulation V2201 versions antérieures à V2201.0010 | ||
| Siemens | N/A | Tecnomatix Plant Simulation V2302 versions antérieures à V2302.0004 |
| Title | Publication Time | Tags | |||||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||||||||||||||||||||||||||||||||
{
"$ref": "https://www.cert.ssi.gouv.fr/openapi.json",
"affected_systems": [
{
"description": "RUGGEDCOM RS900F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "COMOS versions ant\u00e9rieures \u00e0 V10.4.4, les vuln\u00e9rabilit\u00e9s CVE-2023-43505, CVE-2023-46601 ne seront pas corrig\u00e9es par l\u0027\u00e9diteur",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC product family V5.0 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC product family V5.1 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC product family V6 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Desigo CC product family V7 toutes les versions sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications Mendix bas\u00e9es sur Mendix 10 versions ant\u00e9rieures \u00e0 V10.4.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications Mendix bas\u00e9es sur Mendix 7.x versions ant\u00e9rieures \u00e0 V7.23.37",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications Mendix bas\u00e9es sur Mendix 8.x versions ant\u00e9rieures \u00e0 V8.18.27",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Applications Mendix bas\u00e9es sur Mendix 9.x versions ant\u00e9rieures \u00e0 V9.24.10",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Studio Pro 10 versions ant\u00e9rieures \u00e0 V10.3.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Studio Pro 7 versions ant\u00e9rieures \u00e0 V7.23.37",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Studio Pro 8 versions ant\u00e9rieures \u00e0 V8.18.27",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Mendix Studio Pro 9 versions ant\u00e9rieures \u00e0 V9.24.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM APE1808 toutes versions utilis\u00e9es avec Nozomi Guardian / CMC versions V22.6.3 \u00e0 23.1.0sans le dernier correctif de s\u00e9curit\u00e9",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2100 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2100F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2100NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2200 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2200F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M2200NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M969 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M969F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM M969NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC30 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC30NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC8388 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC8388 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC8388NC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RMC8388NC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RP110 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RP110NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600F versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600FNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600T versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS1600TNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS400 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS400F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS400NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS401 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS401NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416NCv2 V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416NCv2 V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416P versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416PF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416PNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416PNCv2 V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416PNCv2 V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416Pv2 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416Pv2 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416v2 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS416v2 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000A versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000ANC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000H versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000HNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000T versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS8000TNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900 (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900 (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900G (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900G (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900G versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GNC(32M) V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GNC(32M) V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GP versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GPF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900GPNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900L versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900LNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900M-GETS-C01 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900M-GETS-XX versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900M-STND-C01 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900M-STND-XX versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900MNC-GETS-C01 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900MNC-GETS-XX toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900MNC-STND-XX toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900MNC-STND-XX-C01 toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900NC(32M) V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900NC(32M) V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS900W versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910L versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910LNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS910W versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS920L versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS920LNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS920W versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS930L versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS930LNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS930W versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS940G versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS940GF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS940GNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS969 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RS969NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100 (32M) V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100 (32M) V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100NC(32M) V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100NC(32M) V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100P versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100PF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2100PNC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2200 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2200F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2200NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2288 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2288 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2288NC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2288NC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300NC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300NC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300P V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300P V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300PF toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300PNC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2300PNC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488 V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488 V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488F toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488NC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG2488NC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG907R versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG908C versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG909R versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG910C versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG920P V4.X versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG920P V5.X versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG920PNC V4.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSG920PNC V5.X toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSL910 versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RSL910NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RST2228 versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RST2228P versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RST916C versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM RST916P versions ant\u00e9rieures \u00e0 V5.6.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i800 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i800NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i801 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i801NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i802 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i802NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i803 versions ant\u00e9rieures \u00e0 V4.3.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "RUGGEDCOM i803NC toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W721-1 RJ45 (6GK5721-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W722-1 RJ45 (6GK5722-1FC00-0AC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AA6) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W734-1 RJ45 (6GK5734-1FX00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W734-1 RJ45 (USA) (6GK5734-1FX00-0AB6) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W738-1 M12 (6GK5738-1GY00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W748-1 M12 (6GK5748-1GD00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W748-1 RJ45 (6GK5748-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W761-1 RJ45 (6GK5761-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 M12 EEC (6GK5774-1FY00-0TB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AA6) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (6GK5774-1FX00-0AC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W774-1 RJ45 (USA) (6GK5774-1FX00-0AB6) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W778-1 M12 (6GK5778-1GY00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W778-1 M12 EEC (6GK5778-1GY00-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W778-1 M12 EEC (USA) (6GK5778-1GY00-0TB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-1 RJ45 (6GK5786-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 RJ45 (6GK5786-2FC00-0AC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2 SFP (6GK5786-2FE00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W786-2IA RJ45 (6GK5786-2HC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-1 M12 (6GK5788-1GD00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-1 RJ45 (6GK5788-1FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 (6GK5788-2GD00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 M12 EEC (6GK5788-2GD00-0TC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W788-2 RJ45 (6GK5788-2FC00-0AC0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1748-1 M12 (6GK5748-1GY01-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-1 M12 (6GK5788-1GY01-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 EEC M12 (6GK5788-2GY01-0TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2 M12 (6GK5788-2GY01-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE W1788-2IA M12 (6GK5788-2HY01-0AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM763-1 (6GK5763-1AL00-7DA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM766-1 (EU) (6GK5766-1GE00-7DA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM766-1 (US) (6GK5766-1GE00-7DB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM766-1 EEC (EU) (6GK5766-1GE00-7TA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WAM766-1 EEC (US) (6GK5766-1GE00-7TB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WUM763-1 (6GK5763-1AL00-3AA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WUM763-1 (6GK5763-1AL00-3DA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WUM766-1 (EU) (6GK5766-1GE00-3DA0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE WUM766-1 (US) (6GK5766-1GE00-3DB0) toutes les versions",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3 (SC, PN) (6GK5205-3BB00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BB00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3 (ST, E/IP) (6GK5205-3BD00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3 (ST, PN) (6GK5205-3BD00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3LD (SC, E/IP) (6GK5205-3BF00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB205-3LD (SC, PN) (6GK5205-3BF00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB208 (E/IP) (6GK5208-0BA00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB208 (PN) (6GK5208-0BA00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3 (SC, E/IP) (6GK5213-3BD00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3 (SC, PN) (6GK5213-3BD00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3 (ST, E/IP) (6GK5213-3BB00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3 (ST, PN) (6GK5213-3BB00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3LD (SC, E/IP) (6GK5213-3BF00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB213-3LD (SC, PN) (6GK5213-3BF00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB216 (E/IP) (6GK5216-0BA00-2TB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XB216 (PN) (6GK5216-0BA00-2AB2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2 (SC) (6GK5206-2BD00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2 (ST/BFOC) (6GK5206-2BB00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2G PoE (54 V DC) (6GK5206-2RS00-5AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2G PoE (6GK5206-2RS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2G PoE EEC (54 V DC) (6GK5206-2RS00-5FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP (6GK5206-2BS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP EEC (6GK5206-2BS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP G (6GK5206-2GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP G (EIP DEF.) (6GK5206-2GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC206-2SFP G EEC (6GK5206-2GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208 (6GK5208-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208EEC (6GK5208-0BA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G (6GK5208-0GA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G (EIP def.) (6GK5208-0GA00-2TC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G EEC (6GK5208-0GA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G PoE (54 V DC) (6GK5208-0RA00-5AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC208G PoE (6GK5208-0RA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216 (6GK5216-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-3G PoE (54 V DC) (6GK5216-3RS00-5AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-3G PoE (6GK5216-3RS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-4C (6GK5216-4BS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-4C G (6GK5216-4GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-4C G (EIP Def.) (6GK5216-4GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216-4C G EEC (6GK5216-4GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC216EEC (6GK5216-0BA00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC224 (6GK5224-0BA00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC224-4C G (6GK5224-4GS00-2AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC224-4C G (EIP Def.) (6GK5224-4GS00-2TC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XC224-4C G EEC (6GK5224-4GS00-2FC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204 (6GK5204-0BA00-2GF2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204 DNA (6GK5204-0BA00-2YF2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204-2BA (6GK5204-2AA00-2GF2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XF204-2BA DNA (6GK5204-2AA00-2YF2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP208 (6GK5208-0HA00-2AS6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP208 (Ethernet/IP) (6GK5208-0HA00-2TS6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP208EEC (6GK5208-0HA00-2ES6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP208PoE EEC (6GK5208-0UA00-5ES6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP216 (6GK5216-0HA00-2AS6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP216 (Ethernet/IP) (6GK5216-0HA00-2TS6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP216EEC (6GK5216-0HA00-2ES6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XP216POE EEC (6GK5216-0UA00-5ES6) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324WG (24 X FE, DC 24V) (6GK5324-0BA00-2AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR324WG (24 x FE, AC 230V) (6GK5324-0BA00-3AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR326-2C PoE WG (6GK5326-2QS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR326-2C PoE WG (without UL) (6GK5326-2QS00-3RR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (24XFE, 4XGE, 24V) (6GK5328-4FS00-2AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (24xFE, 4xGE,DC24V) (6GK5328-4FS00-2RR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (24xFE,4xGE,AC230V) (6GK5328-4FS00-3RR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (28xGE, AC 230V) (6GK5328-4SS00-3AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SCALANCE XR328-4C WG (28xGE, DC 24V) (6GK5328-4SS00-2AR3) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC MV500 family versions ant\u00e9rieures \u00e0 V3.3.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIMATIC PCS neo versions ant\u00e9rieures \u00e0 V4.1",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SINEC PNI versions ant\u00e9rieures \u00e0 V2.0",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE XC206-2 (6AG1206-2BB00-7AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE XC206-2SFP (6AG1206-2BS00-7AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE XC208 (6AG1208-0BA00-7AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPLUS NET SCALANCE XC216-4C (6AG1216-4BS00-7AC2) versions ant\u00e9rieures \u00e0 V4.5",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "SIPROTEC 4 7SJ66 versions ant\u00e9rieures \u00e0 V4.41",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Siemens OPC UA Modelling Editor (SiOME) versions ant\u00e9rieures \u00e0 V2.8",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter Femap V2301 versions ant\u00e9rieures \u00e0 V2301.0003",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Simcenter Femap V2306 versions ant\u00e9rieures \u00e0 V2306.0001",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation V2201 versions ant\u00e9rieures \u00e0 V2201.0010",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
},
{
"description": "Tecnomatix Plant Simulation V2302 versions ant\u00e9rieures \u00e0 V2302.0004",
"product": {
"name": "N/A",
"vendor": {
"name": "Siemens",
"scada": true
}
}
}
],
"affected_systems_content": null,
"content": "## Solution\n\nSe r\u00e9f\u00e9rer au bulletin de s\u00e9curit\u00e9 de l\u0027\u00e9diteur pour l\u0027obtention des\ncorrectifs (cf. section Documentation).\n",
"cves": [
{
"name": "CVE-2023-24895",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24895"
},
{
"name": "CVE-2023-0216",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0216"
},
{
"name": "CVE-2020-35460",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-35460"
},
{
"name": "CVE-2023-0401",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0401"
},
{
"name": "CVE-2023-33135",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33135"
},
{
"name": "CVE-2023-1530",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-1530"
},
{
"name": "CVE-2023-22669",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22669"
},
{
"name": "CVE-2023-44321",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44321"
},
{
"name": "CVE-2023-3935",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3935"
},
{
"name": "CVE-2023-46096",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46096"
},
{
"name": "CVE-2023-44317",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44317"
},
{
"name": "CVE-2022-4304",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4304"
},
{
"name": "CVE-2023-38072",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38072"
},
{
"name": "CVE-2023-24897",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24897"
},
{
"name": "CVE-2022-44792",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44792"
},
{
"name": "CVE-2023-3817",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3817"
},
{
"name": "CVE-2023-38075",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38075"
},
{
"name": "CVE-2019-12256",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12256"
},
{
"name": "CVE-2023-35788",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-35788"
},
{
"name": "CVE-2022-28809",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28809"
},
{
"name": "CVE-2023-24936",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-24936"
},
{
"name": "CVE-2023-38073",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38073"
},
{
"name": "CVE-2023-46097",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46097"
},
{
"name": "CVE-2019-12258",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12258"
},
{
"name": "CVE-2020-25020",
"url": "https://www.cve.org/CVERecord?id=CVE-2020-25020"
},
{
"name": "CVE-2022-4203",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4203"
},
{
"name": "CVE-2022-44793",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-44793"
},
{
"name": "CVE-2023-33128",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33128"
},
{
"name": "CVE-2019-12259",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12259"
},
{
"name": "CVE-2023-0217",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0217"
},
{
"name": "CVE-2023-44320",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44320"
},
{
"name": "CVE-2022-39158",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-39158"
},
{
"name": "CVE-2022-28808",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28808"
},
{
"name": "CVE-2019-12261",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12261"
},
{
"name": "CVE-2023-46099",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46099"
},
{
"name": "CVE-2023-46590",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46590"
},
{
"name": "CVE-2023-2932",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2932"
},
{
"name": "CVE-2023-41033",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41033"
},
{
"name": "CVE-2023-46098",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46098"
},
{
"name": "CVE-2022-37434",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-37434"
},
{
"name": "CVE-2021-20094",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-20094"
},
{
"name": "CVE-2022-28807",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-28807"
},
{
"name": "CVE-2023-38071",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38071"
},
{
"name": "CVE-2023-45794",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-45794"
},
{
"name": "CVE-2019-12263",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12263"
},
{
"name": "CVE-2021-20093",
"url": "https://www.cve.org/CVERecord?id=CVE-2021-20093"
},
{
"name": "CVE-2023-44319",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44319"
},
{
"name": "CVE-2023-46601",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-46601"
},
{
"name": "CVE-2023-32032",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32032"
},
{
"name": "CVE-2022-4450",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-4450"
},
{
"name": "CVE-2023-2650",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2650"
},
{
"name": "CVE-2022-47522",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-47522"
},
{
"name": "CVE-2023-38070",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38070"
},
{
"name": "CVE-2022-23095",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23095"
},
{
"name": "CVE-2023-44322",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44322"
},
{
"name": "CVE-2023-29245",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29245"
},
{
"name": "CVE-2023-43503",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43503"
},
{
"name": "CVE-2019-12260",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12260"
},
{
"name": "CVE-2022-23218",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23218"
},
{
"name": "CVE-2023-28260",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-28260"
},
{
"name": "CVE-2023-43505",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43505"
},
{
"name": "CVE-2023-38074",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38074"
},
{
"name": "CVE-2019-12262",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12262"
},
{
"name": "CVE-2023-29331",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-29331"
},
{
"name": "CVE-2019-12255",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12255"
},
{
"name": "CVE-2023-44374",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44374"
},
{
"name": "CVE-2023-43504",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-43504"
},
{
"name": "CVE-2023-0933",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-0933"
},
{
"name": "CVE-2023-2567",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2567"
},
{
"name": "CVE-2023-32649",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-32649"
},
{
"name": "CVE-2022-41032",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-41032"
},
{
"name": "CVE-2023-4863",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-4863"
},
{
"name": "CVE-2023-21808",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-21808"
},
{
"name": "CVE-2023-2931",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2931"
},
{
"name": "CVE-2023-2975",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-2975"
},
{
"name": "CVE-2022-30184",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-30184"
},
{
"name": "CVE-2019-12265",
"url": "https://www.cve.org/CVERecord?id=CVE-2019-12265"
},
{
"name": "CVE-2023-44373",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44373"
},
{
"name": "CVE-2023-3446",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-3446"
},
{
"name": "CVE-2022-23219",
"url": "https://www.cve.org/CVERecord?id=CVE-2022-23219"
},
{
"name": "CVE-2023-38076",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-38076"
},
{
"name": "CVE-2023-41032",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-41032"
},
{
"name": "CVE-2023-33126",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-33126"
},
{
"name": "CVE-2023-44318",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-44318"
},
{
"name": "CVE-2023-22670",
"url": "https://www.cve.org/CVERecord?id=CVE-2023-22670"
}
],
"initial_release_date": "2023-11-14T00:00:00",
"last_revision_date": "2023-11-14T00:00:00",
"links": [],
"reference": "CERTFR-2023-AVI-0935",
"revisions": [
{
"description": "Version initiale",
"revision_date": "2023-11-14T00:00:00.000000"
}
],
"risks": [
{
"description": "D\u00e9ni de service \u00e0 distance"
},
{
"description": "Injection de code indirecte \u00e0 distance (XSS)"
},
{
"description": "Ex\u00e9cution de code arbitraire \u00e0 distance"
},
{
"description": "Atteinte \u00e0 l\u0027int\u00e9grit\u00e9 des donn\u00e9es"
},
{
"description": "Contournement de la politique de s\u00e9curit\u00e9"
},
{
"description": "Atteinte \u00e0 la confidentialit\u00e9 des donn\u00e9es"
},
{
"description": "\u00c9l\u00e9vation de privil\u00e8ges"
}
],
"summary": "De multiples vuln\u00e9rabilit\u00e9s ont \u00e9t\u00e9 d\u00e9couvertes dans \u003cspan\nclass=\"textit\"\u003eles produits Siemens\u003c/span\u003e. Certaines d\u0027entre elles\npermettent \u00e0 un attaquant de provoquer une \u00e9l\u00e9vation de privil\u00e8ges, un\nd\u00e9ni de service \u00e0 distance et une ex\u00e9cution de code arbitraire \u00e0\ndistance.\n",
"title": "Multiples vuln\u00e9rabilit\u00e9s dans les produits Siemens",
"vendor_advisories": [
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-617233 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-292063.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-268517 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-084182.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-197270 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-787941.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-099606 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-625850.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-137900 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-137900.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-456933 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-456933.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-787941 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-457702.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-084182 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-887122.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-887122 du 08 novembre 2022",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-150063.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-150063 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-268517.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-699386 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-197270.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-292063 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-617233.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-625850 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-699386.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-457702 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-099606.html"
},
{
"published_at": null,
"title": "Bulletin de s\u00e9curit\u00e9 Siemens SSA-478780 du 14 novembre 2023",
"url": "https://cert-portal.siemens.com/productcert/html/ssa-478780.html"
}
]
}
GSD-2023-22670
Vulnerability from gsd - Updated: 2023-12-13 01:20{
"GSD": {
"alias": "CVE-2023-22670",
"id": "GSD-2023-22670"
},
"gsd": {
"metadata": {
"exploitCode": "unknown",
"remediation": "unknown",
"reportConfidence": "confirmed",
"type": "vulnerability"
},
"osvSchema": {
"aliases": [
"CVE-2023-22670"
],
"details": "A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.",
"id": "GSD-2023-22670",
"modified": "2023-12-13T01:20:42.755616Z",
"schema_version": "1.4.0"
}
},
"namespaces": {
"cve.org": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2023-22670",
"STATE": "PUBLIC"
},
"affects": {
"vendor": {
"vendor_data": [
{
"product": {
"product_data": [
{
"product_name": "n/a",
"version": {
"version_data": [
{
"version_value": "n/a"
}
]
}
}
]
},
"vendor_name": "n/a"
}
]
}
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "eng",
"value": "A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "eng",
"value": "n/a"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.opendesign.com/security-advisories",
"refsource": "MISC",
"url": "https://www.opendesign.com/security-advisories"
}
]
}
},
"nvd.nist.gov": {
"configurations": {
"CVE_data_version": "4.0",
"nodes": [
{
"children": [],
"cpe_match": [
{
"cpe23Uri": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*",
"cpe_name": [],
"versionEndExcluding": "2023.6",
"vulnerable": true
}
],
"operator": "OR"
}
]
},
"cve": {
"CVE_data_meta": {
"ASSIGNER": "cve@mitre.org",
"ID": "CVE-2023-22670"
},
"data_format": "MITRE",
"data_type": "CVE",
"data_version": "4.0",
"description": {
"description_data": [
{
"lang": "en",
"value": "A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process."
}
]
},
"problemtype": {
"problemtype_data": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
]
}
]
},
"references": {
"reference_data": [
{
"name": "https://www.opendesign.com/security-advisories",
"refsource": "MISC",
"tags": [
"Vendor Advisory"
],
"url": "https://www.opendesign.com/security-advisories"
}
]
}
},
"impact": {
"baseMetricV3": {
"cvssV3": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9
}
},
"lastModifiedDate": "2023-04-24T20:13Z",
"publishedDate": "2023-04-15T01:15Z"
}
}
}
GHSA-V2G6-R34C-4X3H
Vulnerability from github – Published: 2023-04-15 03:30 – Updated: 2024-04-04 03:29A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.
{
"affected": [],
"aliases": [
"CVE-2023-22670"
],
"database_specific": {
"cwe_ids": [
"CWE-787"
],
"github_reviewed": false,
"github_reviewed_at": null,
"nvd_published_at": "2023-04-15T01:15:00Z",
"severity": "HIGH"
},
"details": "A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process.",
"id": "GHSA-v2g6-r34c-4x3h",
"modified": "2024-04-04T03:29:10Z",
"published": "2023-04-15T03:30:14Z",
"references": [
{
"type": "ADVISORY",
"url": "https://nvd.nist.gov/vuln/detail/CVE-2023-22670"
},
{
"type": "WEB",
"url": "https://www.opendesign.com/security-advisories"
}
],
"schema_version": "1.4.0",
"severity": [
{
"score": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"type": "CVSS_V3"
}
]
}
FKIE_CVE-2023-22670
Vulnerability from fkie_nvd - Published: 2023-04-15 01:15 - Updated: 2025-05-05 16:157.8 (High) - CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://www.opendesign.com/security-advisories | Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.opendesign.com/security-advisories | Vendor Advisory |
| Vendor | Product | Version | |
|---|---|---|---|
| opendesign | drawings_sdk | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:opendesign:drawings_sdk:*:*:*:*:*:*:*:*",
"matchCriteriaId": "178B0588-1D9B-408B-9612-BD50CA51E7CC",
"versionEndExcluding": "2023.6",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A heap-based buffer overflow exists in the DXF file reading procedure in Open Design Alliance Drawings SDK before 2023.6. The specific flaw exists within the parsing of DXF files. The issue results from the lack of proper validation of the length of user-supplied XRecord data prior to copying it to a fixed-length heap-based buffer. An attacker can leverage this vulnerability to execute code in the context of the current process."
}
],
"id": "CVE-2023-22670",
"lastModified": "2025-05-05T16:15:29.747",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-04-15T01:15:07.007",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://www.opendesign.com/security-advisories"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.opendesign.com/security-advisories"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
CNVD-2023-09119
Vulnerability from cnvd - Published: 2023-02-15用户可参考如下供应商提供的安全公告获得补丁信息: https://cert-portal.siemens.com/productcert/html/ssa-491245.html
| Name | ['Siemens Solid Edge SE2023 < V2023Update2', 'Siemens Solid Edge SE2022'] |
|---|
{
"cves": {
"cve": {
"cveNumber": "CVE-2023-22670"
}
},
"description": "Siemens Solid Edge\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u4e09\u7ef4CAD\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u53ef\u7528\u4e8e\u96f6\u4ef6\u8bbe\u8ba1\u3001\u88c5\u914d\u8bbe\u8ba1\u3001\u94a3\u91d1\u8bbe\u8ba1\u3001\u710a\u63a5\u8bbe\u8ba1\u7b49\u884c\u4e1a\u3002\n\nSiemens Solid Edge\u5b58\u5728\u5806\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002",
"formalWay": "\u7528\u6237\u53ef\u53c2\u8003\u5982\u4e0b\u4f9b\u5e94\u5546\u63d0\u4f9b\u7684\u5b89\u5168\u516c\u544a\u83b7\u5f97\u8865\u4e01\u4fe1\u606f\uff1a\r\nhttps://cert-portal.siemens.com/productcert/html/ssa-491245.html",
"isEvent": "\u901a\u7528\u8f6f\u786c\u4ef6\u6f0f\u6d1e",
"number": "CNVD-2023-09119",
"openTime": "2023-02-15",
"patchDescription": "Siemens Solid Edge\u662f\u5fb7\u56fd\u897f\u95e8\u5b50\uff08Siemens\uff09\u516c\u53f8\u7684\u4e00\u6b3e\u4e09\u7ef4CAD\u8f6f\u4ef6\u3002\u8be5\u8f6f\u4ef6\u53ef\u7528\u4e8e\u96f6\u4ef6\u8bbe\u8ba1\u3001\u88c5\u914d\u8bbe\u8ba1\u3001\u94a3\u91d1\u8bbe\u8ba1\u3001\u710a\u63a5\u8bbe\u8ba1\u7b49\u884c\u4e1a\u3002\r\n\r\nSiemens Solid Edge\u5b58\u5728\u5806\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff0c\u653b\u51fb\u8005\u53ef\u5229\u7528\u8be5\u6f0f\u6d1e\u5728\u5f53\u524d\u8fdb\u7a0b\u7684\u4e0a\u4e0b\u6587\u4e2d\u6267\u884c\u4ee3\u7801\u3002\u76ee\u524d\uff0c\u4f9b\u5e94\u5546\u53d1\u5e03\u4e86\u5b89\u5168\u516c\u544a\u53ca\u76f8\u5173\u8865\u4e01\u4fe1\u606f\uff0c\u4fee\u590d\u4e86\u6b64\u6f0f\u6d1e\u3002",
"patchName": "Siemens Solid Edge\u5806\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2023-09119\uff09\u7684\u8865\u4e01",
"products": {
"product": [
"Siemens Solid Edge SE2023 \u003c V2023Update2",
"Siemens Solid Edge SE2022"
]
},
"referenceLink": "https://cert-portal.siemens.com/productcert/html/ssa-491245.html",
"serverity": "\u9ad8",
"submitTime": "2023-02-14",
"title": "Siemens Solid Edge\u5806\u7f13\u51b2\u533a\u6ea2\u51fa\u6f0f\u6d1e\uff08CNVD-2023-09119\uff09"
}
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.