CVE-2023-4088 (GCVE-0-2023-4088)

Vulnerability from cvelistv5 – Published: 2023-09-20 02:26 – Updated: 2024-09-24 18:27
VLAI?
Title
Malicious Code Execution Vulnerability in FA Engineering Software Products
Summary
Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder.
CWE
  • CWE-276 - Incorrect Default Permissions
Assigner
Impacted products
Vendor Product Version
Mitsubishi Electric Corporation GX Works3 Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation AL-PCS/WIN-E Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation CPU Module Logging Configuration Tool Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation EZSocket Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation FR Configurator2 Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation FX Configurator-EN Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation FX Configurator-EN-L Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation FX Configurator-FP Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation GT Designer3 Version1(GOT1000) Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation GT Designer3 Version1(GOT2000) Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation GT SoftGOT1000 Version3 Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation GT SoftGOT2000 Version1 Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation GX LogViewer Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation GX Works2 Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation MELSOFT FieldDeviceConfigurator Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation MELSOFT iQ AppPortal Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation MELSOFT MaiLab Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation MELSOFT Navigator Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation MELSOFT Update Manager Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation MX Component Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation MX Sheet Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation PX Developer Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation RT ToolBox3 Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation RT VisualBox Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation Data Transfer Affected: all versions
Create a notification for this product.
    Mitsubishi Electric Corporation Data Transfer Classic Affected: all versions
Create a notification for this product.
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T07:17:12.060Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://jvn.jp/vu/JVNVU96447193/index.html"
          },
          {
            "tags": [
              "government-resource",
              "x_transferred"
            ],
            "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-4088",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-09-24T18:27:00.307770Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-09-24T18:27:11.655Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "GX Works3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "AL-PCS/WIN-E",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "CPU Module Logging Configuration Tool",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "EZSocket",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FR Configurator2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FX Configurator-EN",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FX Configurator-EN-L",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "FX Configurator-FP",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT1000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT Designer3 Version1(GOT2000)",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT SoftGOT1000 Version3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GT SoftGOT2000 Version1",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX LogViewer",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "GX Works2",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT FieldDeviceConfigurator",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT iQ AppPortal",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT MaiLab",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Navigator",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MELSOFT Update Manager",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Component",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "MX Sheet",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "PX Developer",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RT ToolBox3",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "RT VisualBox",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Data Transfer",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "Data Transfer Classic",
          "vendor": "Mitsubishi Electric Corporation",
          "versions": [
            {
              "status": "affected",
              "version": "all versions"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder."
            }
          ],
          "value": "Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder."
        }
      ],
      "impacts": [
        {
          "descriptions": [
            {
              "lang": "en",
              "value": "Malicious Code Execution"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 9.3,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-276",
              "description": "CWE-276 Incorrect Default Permissions",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-07-04T09:16:28.950Z",
        "orgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
        "shortName": "Mitsubishi"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://jvn.jp/vu/JVNVU96447193/index.html"
        },
        {
          "tags": [
            "government-resource"
          ],
          "url": "https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "Malicious Code Execution Vulnerability in FA Engineering Software Products",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e0f77b61-78fd-4786-b3fb-1ee347a748ad",
    "assignerShortName": "Mitsubishi",
    "cveId": "CVE-2023-4088",
    "datePublished": "2023-09-20T02:26:43.901Z",
    "dateReserved": "2023-08-02T04:52:49.923Z",
    "dateUpdated": "2024-09-24T18:27:11.655Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU96447193/index.html\", \"tags\": [\"government-resource\", \"x_transferred\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03\", \"tags\": [\"government-resource\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T07:17:12.060Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-4088\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-09-24T18:27:00.307770Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-09-24T18:27:06.570Z\"}}], \"cna\": {\"title\": \"Malicious Code Execution Vulnerability in FA Engineering Software Products\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"descriptions\": [{\"lang\": \"en\", \"value\": \"Malicious Code Execution\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9.3, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GX Works3\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"AL-PCS/WIN-E\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"CPU Module Logging Configuration Tool\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"EZSocket\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"FR Configurator2\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"FX Configurator-EN\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"FX Configurator-EN-L\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"FX Configurator-FP\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GT Designer3 Version1(GOT1000)\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GT Designer3 Version1(GOT2000)\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GT SoftGOT1000 Version3\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GT SoftGOT2000 Version1\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GX LogViewer\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"GX Works2\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MELSOFT FieldDeviceConfigurator\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MELSOFT iQ AppPortal\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MELSOFT MaiLab\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MELSOFT Navigator\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MELSOFT Update Manager\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MX Component\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"MX Sheet\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"PX Developer\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"RT ToolBox3\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"RT VisualBox\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Data Transfer\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"Mitsubishi Electric Corporation\", \"product\": \"Data Transfer Classic\", \"versions\": [{\"status\": \"affected\", \"version\": \"all versions\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.mitsubishielectric.com/en/psirt/vulnerability/pdf/2023-010_en.pdf\", \"tags\": [\"vendor-advisory\"]}, {\"url\": \"https://jvn.jp/vu/JVNVU96447193/index.html\", \"tags\": [\"government-resource\"]}, {\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-23-269-03\", \"tags\": [\"government-resource\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Incorrect Default Permissions vulnerability in Mitsubishi Electric Corporation multiple FA engineering software products allows a malicious local attacker to execute a malicious code, resulting in information disclosure, tampering with and deletion, or a denial-of-service (DoS) condition, if the product is installed in a folder other than the default installation folder.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-276\", \"description\": \"CWE-276 Incorrect Default Permissions\"}]}], \"providerMetadata\": {\"orgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"shortName\": \"Mitsubishi\", \"dateUpdated\": \"2024-07-04T09:16:28.950Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-4088\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-09-24T18:27:11.655Z\", \"dateReserved\": \"2023-08-02T04:52:49.923Z\", \"assignerOrgId\": \"e0f77b61-78fd-4786-b3fb-1ee347a748ad\", \"datePublished\": \"2023-09-20T02:26:43.901Z\", \"assignerShortName\": \"Mitsubishi\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…