CVE-2024-1591 (GCVE-0-2024-1591)

Vulnerability from cvelistv5 – Published: 2024-02-16 18:54 – Updated: 2024-08-01 18:48
VLAI?
Title
Privilege Management for Windows < 24.1 Information Leak
Summary
Prior to version 24.1, a local authenticated attacker can view Sysvol when Privilege Management for Windows is configured to use a GPO policy. This allows them to view the policy and potentially find configuration issues.
CWE
  • CWE-200 - Exposure of Sensitive Information to an Unauthorized Actor
Assigner
BT
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-1591",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-02-18T00:44:16.042553Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-06-04T18:00:12.988Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      },
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-01T18:48:20.658Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "x_transferred"
            ],
            "url": "https://www.beyondtrust.com/trust-center/security-advisories/bt24-02"
          }
        ],
        "title": "CVE Program Container"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "platforms": [
            "Windows"
          ],
          "product": "Privilege Management for Windows",
          "vendor": "BeyondTrust",
          "versions": [
            {
              "lessThan": "24.1",
              "status": "affected",
              "version": "1",
              "versionType": "custom"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "Prior to version 24.1, a local authenticated attacker can view Sysvol when Privilege Management for Windows is configured to use a GPO policy. This allows them to view the policy and potentially find configuration issues."
            }
          ],
          "value": "Prior to version 24.1, a local authenticated attacker can view Sysvol when Privilege Management for Windows is configured to use a GPO policy. This allows them to view the policy and potentially find configuration issues."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-176",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-176 Configuration/Environment Manipulation"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 3.3,
            "baseSeverity": "LOW",
            "confidentialityImpact": "LOW",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-200",
              "description": "CWE-200 Exposure of Sensitive Information to an Unauthorized Actor",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-02-16T18:54:33.382Z",
        "orgId": "13061848-ea10-403d-bd75-c83a022c2891",
        "shortName": "BT"
      },
      "references": [
        {
          "url": "https://www.beyondtrust.com/trust-center/security-advisories/bt24-02"
        }
      ],
      "source": {
        "advisory": "BT24-02",
        "discovery": "UNKNOWN"
      },
      "title": "Privilege Management for Windows \u003c 24.1 Information Leak",
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "13061848-ea10-403d-bd75-c83a022c2891",
    "assignerShortName": "BT",
    "cveId": "CVE-2024-1591",
    "datePublished": "2024-02-16T18:54:33.382Z",
    "dateReserved": "2024-02-16T17:32:29.581Z",
    "dateUpdated": "2024-08-01T18:48:20.658Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.beyondtrust.com/trust-center/security-advisories/bt24-02\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-01T18:48:20.658Z\"}}, {\"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-1591\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-02-18T00:44:16.042553Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-23T19:01:11.614Z\"}, \"title\": \"CISA ADP Vulnrichment\"}], \"cna\": {\"title\": \"Privilege Management for Windows \u003c 24.1 Information Leak\", \"source\": {\"advisory\": \"BT24-02\", \"discovery\": \"UNKNOWN\"}, \"impacts\": [{\"capecId\": \"CAPEC-176\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-176 Configuration/Environment Manipulation\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 3.3, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"LOW\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:L/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"LOW\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"BeyondTrust\", \"product\": \"Privilege Management for Windows\", \"versions\": [{\"status\": \"affected\", \"version\": \"1\", \"lessThan\": \"24.1\", \"versionType\": \"custom\"}], \"platforms\": [\"Windows\"], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.beyondtrust.com/trust-center/security-advisories/bt24-02\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Prior to version 24.1, a local authenticated attacker can view Sysvol when Privilege Management for Windows is configured to use a GPO policy. This allows them to view the policy and potentially find configuration issues.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Prior to version 24.1, a local authenticated attacker can view Sysvol when Privilege Management for Windows is configured to use a GPO policy. This allows them to view the policy and potentially find configuration issues.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-200\", \"description\": \"CWE-200 Exposure of Sensitive Information to an Unauthorized Actor\"}]}], \"providerMetadata\": {\"orgId\": \"13061848-ea10-403d-bd75-c83a022c2891\", \"shortName\": \"BT\", \"dateUpdated\": \"2024-02-16T18:54:33.382Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-1591\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-01T18:48:20.658Z\", \"dateReserved\": \"2024-02-16T17:32:29.581Z\", \"assignerOrgId\": \"13061848-ea10-403d-bd75-c83a022c2891\", \"datePublished\": \"2024-02-16T18:54:33.382Z\", \"assignerShortName\": \"BT\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…