CVE-2024-32742 (GCVE-0-2024-32742)
Vulnerability from cvelistv5 – Published: 2024-05-14 10:02 – Updated: 2024-08-02 02:20
VLAI?
Summary
A vulnerability has been identified in SIMATIC CN 4100 (All versions < V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.
Severity ?
CWE
- CWE-1326 - Missing Immutable Root of Trust in Hardware
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Siemens | SIMATIC CN 4100 |
Affected:
0 , < V3.0
(custom)
|
{
"containers": {
"adp": [
{
"affected": [
{
"cpes": [
"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*"
],
"defaultStatus": "unknown",
"product": "simatic_cn_4100",
"vendor": "siemens",
"versions": [
{
"lessThan": "3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-32742",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-05-14T12:43:18.352073Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-06-06T17:34:34.134Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
},
{
"providerMetadata": {
"dateUpdated": "2024-08-02T02:20:35.285Z",
"orgId": "af854a3a-2127-422b-91ae-364da2661108",
"shortName": "CVE"
},
"references": [
{
"tags": [
"x_transferred"
],
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
],
"title": "CVE Program Container"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "SIMATIC CN 4100",
"vendor": "Siemens",
"versions": [
{
"lessThan": "V3.0",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.6,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1326",
"description": "CWE-1326: Missing Immutable Root of Trust in Hardware",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-05-15T07:24:36.881Z",
"orgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"shortName": "siemens"
},
"references": [
{
"url": "https://cert-portal.siemens.com/productcert/html/ssa-273900.html"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "cec7a2ec-15b4-4faf-bd53-b40f371f3a77",
"assignerShortName": "siemens",
"cveId": "CVE-2024-32742",
"datePublished": "2024-05-14T10:02:49.388Z",
"dateReserved": "2024-04-17T12:35:40.942Z",
"dateUpdated": "2024-08-02T02:20:35.285Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-273900.html\", \"tags\": [\"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T02:20:35.285Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-32742\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-05-14T12:43:18.352073Z\"}}}], \"affected\": [{\"cpes\": [\"cpe:2.3:a:siemens:simatic_cn_4100:*:*:*:*:*:*:*:*\"], \"vendor\": \"siemens\", \"product\": \"simatic_cn_4100\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-05-14T12:43:57.818Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.6, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H/E:P/RL:O/RC:C\"}}], \"affected\": [{\"vendor\": \"Siemens\", \"product\": \"SIMATIC CN 4100\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"lessThan\": \"V3.0\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://cert-portal.siemens.com/productcert/html/ssa-273900.html\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been identified in SIMATIC CN 4100 (All versions \u003c V3.0). The affected device contains an unrestricted USB port. An attacker with local access to the device could potentially misuse the port for booting another operating system and gain complete read/write access to the filesystem.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1326\", \"description\": \"CWE-1326: Missing Immutable Root of Trust in Hardware\"}]}], \"providerMetadata\": {\"orgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"shortName\": \"siemens\", \"dateUpdated\": \"2024-05-15T07:24:36.881Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-32742\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-08-02T02:20:35.285Z\", \"dateReserved\": \"2024-04-17T12:35:40.942Z\", \"assignerOrgId\": \"cec7a2ec-15b4-4faf-bd53-b40f371f3a77\", \"datePublished\": \"2024-05-14T10:02:49.388Z\", \"assignerShortName\": \"siemens\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…