CVE-2024-34579 (GCVE-0-2024-34579)
Vulnerability from cvelistv5 – Published: 2025-01-17 00:21 – Updated: 2025-02-12 20:31
VLAI?
Title
Fuji Electric Alpha5 SMART Stack-Based Buffer Overflow
Summary
Fuji Electric Alpha5 SMART
is vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.
Severity ?
CWE
- CWE-121 - Stack-Based Buffer Overflow
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Fuji Electric | Alpha5 SMART |
Affected:
0 , ≤ 4.5
(custom)
|
Credits
An anonymous researcher working with Trend Micro's Zero Day Initiative reported this vulnerability to CISA
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-34579",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-17T13:49:32.350724Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-02-12T20:31:24.377Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"product": "Alpha5 SMART",
"vendor": "Fuji Electric",
"versions": [
{
"lessThanOrEqual": "4.5",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "An anonymous researcher working with Trend Micro\u0027s Zero Day Initiative reported this vulnerability to CISA"
}
],
"datePublic": "2025-01-16T18:00:00.000Z",
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Fuji Electric Alpha5 SMART \n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eis vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.\u003c/span\u003e\n\n\u003cbr\u003e"
}
],
"value": "Fuji Electric Alpha5 SMART \n\nis vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
},
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "LOCAL",
"baseScore": 8.5,
"baseSeverity": "HIGH",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "PASSIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-Based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-17T00:21:36.411Z",
"orgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"shortName": "icscert"
},
"references": [
{
"url": "https://www.cisa.gov/news-events/ics-advisories/icsa-25-016-05"
}
],
"solutions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "\u003cp\u003eFuji Electric has indicated that the vulnerabilities will not be fixed in Alpha5 SMART. Fuji Electric recommends users upgrade their systems to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.fujielectric.com/products/drives_inverters/servo/product_series/alpha7_overview.html\"\u003eAlpha7\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eFor assistance, reach out directly to \u003ca target=\"_blank\" rel=\"nofollow\" href=\"https://www.fujielectric.com/contact/\"\u003eFuji Electric\u0027s support team\u003c/a\u003e.\u003c/p\u003e"
}
],
"value": "Fuji Electric has indicated that the vulnerabilities will not be fixed in Alpha5 SMART. Fuji Electric recommends users upgrade their systems to Alpha7 https://www.fujielectric.com/products/drives_inverters/servo/product_series/alpha7_overview.html .\n\nFor assistance, reach out directly to Fuji Electric\u0027s support team https://www.fujielectric.com/contact/ ."
}
],
"source": {
"advisory": "ICSA-25-016-05",
"discovery": "EXTERNAL"
},
"title": "Fuji Electric Alpha5 SMART Stack-Based Buffer Overflow",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "7d14cffa-0d7d-4270-9dc0-52cabd5a23a6",
"assignerShortName": "icscert",
"cveId": "CVE-2024-34579",
"datePublished": "2025-01-17T00:21:36.411Z",
"dateReserved": "2024-05-20T14:11:06.262Z",
"dateUpdated": "2025-02-12T20:31:24.377Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-34579\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-17T13:49:32.350724Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-02-12T20:27:13.116Z\"}}], \"cna\": {\"title\": \"Fuji Electric Alpha5 SMART Stack-Based Buffer Overflow\", \"source\": {\"advisory\": \"ICSA-25-016-05\", \"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"An anonymous researcher working with Trend Micro\u0027s Zero Day Initiative reported this vulnerability to CISA\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}, {\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.5, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:L/AC:L/AT:N/PR:N/UI:P/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"PASSIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Fuji Electric\", \"product\": \"Alpha5 SMART\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"4.5\"}], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Fuji Electric has indicated that the vulnerabilities will not be fixed in Alpha5 SMART. Fuji Electric recommends users upgrade their systems to Alpha7 https://www.fujielectric.com/products/drives_inverters/servo/product_series/alpha7_overview.html .\\n\\nFor assistance, reach out directly to Fuji Electric\u0027s support team https://www.fujielectric.com/contact/ .\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\u003cp\u003eFuji Electric has indicated that the vulnerabilities will not be fixed in Alpha5 SMART. Fuji Electric recommends users upgrade their systems to \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.fujielectric.com/products/drives_inverters/servo/product_series/alpha7_overview.html\\\"\u003eAlpha7\u003c/a\u003e.\u003c/p\u003e\u003cp\u003eFor assistance, reach out directly to \u003ca target=\\\"_blank\\\" rel=\\\"nofollow\\\" href=\\\"https://www.fujielectric.com/contact/\\\"\u003eFuji Electric\u0027s support team\u003c/a\u003e.\u003c/p\u003e\", \"base64\": false}]}], \"datePublic\": \"2025-01-16T18:00:00.000Z\", \"references\": [{\"url\": \"https://www.cisa.gov/news-events/ics-advisories/icsa-25-016-05\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Fuji Electric Alpha5 SMART \\n\\nis vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Fuji Electric Alpha5 SMART \\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eis vulnerable to a stack-based buffer overflow, which may allow an attacker to execute arbitrary code.\u003c/span\u003e\\n\\n\u003cbr\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-Based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"shortName\": \"icscert\", \"dateUpdated\": \"2025-01-17T00:21:36.411Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-34579\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-02-12T20:31:24.377Z\", \"dateReserved\": \"2024-05-20T14:11:06.262Z\", \"assignerOrgId\": \"7d14cffa-0d7d-4270-9dc0-52cabd5a23a6\", \"datePublished\": \"2025-01-17T00:21:36.411Z\", \"assignerShortName\": \"icscert\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…