CVE-2024-52275 (GCVE-0-2024-52275)
Vulnerability from cvelistv5 – Published: 2024-12-04 10:20 – Updated: 2024-12-04 21:02
VLAI?
Title
Denial of Service on Tenda AC6V2 Due To Stack Overflow
Summary
Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromWizardHandle modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50.
Severity ?
CWE
- CWE-121 - Stack-based Buffer Overflow
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Shenzhen Tenda Technology Co | Tenda AC6V2 |
Affected:
0 , ≤ 15.03.06.50
(custom)
|
Credits
Ba1100n
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2024-52275",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2024-12-04T19:09:14.134021Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2024-12-04T21:02:19.667Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"collectionURL": "https://www.tendacn.com/download",
"defaultStatus": "unknown",
"modules": [
"fromWizardHandle"
],
"product": "Tenda AC6V2",
"vendor": "Shenzhen Tenda Technology Co",
"versions": [
{
"lessThanOrEqual": "15.03.06.50",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "Ba1100n"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": true,
"type": "text/markdown",
"value": "Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromWizardHandle modules) allows Overflow Buffers.\u003cp\u003eThis issue affects Tenda AC6V2: through 15.03.06.50.\u003c/p\u003e"
}
],
"value": "Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromWizardHandle modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50."
}
],
"impacts": [
{
"capecId": "CAPEC-100",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-100 Overflow Buffers"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"privilegesRequired": "LOW",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "NONE",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-121",
"description": "CWE-121 Stack-based Buffer Overflow",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2024-12-04T10:20:15.778Z",
"orgId": "2fdefc65-d750-4b8d-96ee-6e2c0c42dbfe",
"shortName": "VULSec"
},
"references": [
{
"tags": [
"vdb-entry",
"exploit",
"technical-description"
],
"url": "https://www.vulsec.org/advisories"
},
{
"tags": [
"x_package"
],
"url": "https://www.tendacn.com/download/detail-3316.html"
},
{
"tags": [
"x_package"
],
"url": "https://www.tendacn.com/download/detail-3794.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Denial of Service on Tenda AC6V2 Due To Stack Overflow",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "2fdefc65-d750-4b8d-96ee-6e2c0c42dbfe",
"assignerShortName": "VULSec",
"cveId": "CVE-2024-52275",
"datePublished": "2024-12-04T10:20:15.778Z",
"dateReserved": "2024-11-06T08:35:09.853Z",
"dateUpdated": "2024-12-04T21:02:19.667Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-52275\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-12-04T19:09:14.134021Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-12-04T19:09:21.184Z\"}}], \"cna\": {\"title\": \"Denial of Service on Tenda AC6V2 Due To Stack Overflow\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"Ba1100n\"}], \"impacts\": [{\"capecId\": \"CAPEC-100\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-100 Overflow Buffers\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 8.3, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:H\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"LOW\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Shenzhen Tenda Technology Co\", \"modules\": [\"fromWizardHandle\"], \"product\": \"Tenda AC6V2\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\", \"versionType\": \"custom\", \"lessThanOrEqual\": \"15.03.06.50\"}], \"collectionURL\": \"https://www.tendacn.com/download\", \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://www.vulsec.org/advisories\", \"tags\": [\"vdb-entry\", \"exploit\", \"technical-description\"]}, {\"url\": \"https://www.tendacn.com/download/detail-3316.html\", \"tags\": [\"x_package\"]}, {\"url\": \"https://www.tendacn.com/download/detail-3794.html\", \"tags\": [\"x_package\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromWizardHandle modules) allows Overflow Buffers.This issue affects Tenda AC6V2: through 15.03.06.50.\", \"supportingMedia\": [{\"type\": \"text/markdown\", \"value\": \"Stack-based Buffer Overflow vulnerability in Shenzhen Tenda Technology Co Tenda AC6V2 (fromWizardHandle modules) allows Overflow Buffers.\u003cp\u003eThis issue affects Tenda AC6V2: through 15.03.06.50.\u003c/p\u003e\", \"base64\": true}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-121\", \"description\": \"CWE-121 Stack-based Buffer Overflow\"}]}], \"providerMetadata\": {\"orgId\": \"2fdefc65-d750-4b8d-96ee-6e2c0c42dbfe\", \"shortName\": \"VULSec\", \"dateUpdated\": \"2024-12-04T10:20:15.778Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2024-52275\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-04T21:02:19.667Z\", \"dateReserved\": \"2024-11-06T08:35:09.853Z\", \"assignerOrgId\": \"2fdefc65-d750-4b8d-96ee-6e2c0c42dbfe\", \"datePublished\": \"2024-12-04T10:20:15.778Z\", \"assignerShortName\": \"VULSec\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…