CVE-2024-56334 (GCVE-0-2024-56334)

Vulnerability from cvelistv5 – Published: 2024-12-20 20:10 – Updated: 2024-12-24 16:32
VLAI?
Title
Command injection vulnerability in getWindowsIEEE8021x (SSID) function in systeminformation
Summary
systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability.
CWE
  • CWE-94 - Improper Control of Generation of Code ('Code Injection')
Assigner
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2024-56334",
                "options": [
                  {
                    "Exploitation": "poc"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-12-24T16:32:16.418664Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-12-24T16:32:35.731Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "references": [
          {
            "tags": [
              "exploit"
            ],
            "url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
          }
        ],
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "product": "systeminformation",
          "vendor": "sebhildebrandt",
          "versions": [
            {
              "status": "affected",
              "version": "\u003c 5.23.7"
            }
          ]
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "value": "systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability."
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "HIGH",
            "baseScore": 7.8,
            "baseSeverity": "HIGH",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "NONE",
            "scope": "UNCHANGED",
            "userInteraction": "REQUIRED",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
            "version": "3.1"
          }
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-94",
              "description": "CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2024-12-20T20:10:12.578Z",
        "orgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
        "shortName": "GitHub_M"
      },
      "references": [
        {
          "name": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m",
          "tags": [
            "x_refsource_CONFIRM"
          ],
          "url": "https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m"
        },
        {
          "name": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41",
          "tags": [
            "x_refsource_MISC"
          ],
          "url": "https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41"
        }
      ],
      "source": {
        "advisory": "GHSA-cvv5-9h9w-qp2m",
        "discovery": "UNKNOWN"
      },
      "title": "Command injection vulnerability in getWindowsIEEE8021x (SSID) function in systeminformation"
    }
  },
  "cveMetadata": {
    "assignerOrgId": "a0819718-46f1-4df5-94e2-005712e83aaa",
    "assignerShortName": "GitHub_M",
    "cveId": "CVE-2024-56334",
    "datePublished": "2024-12-20T20:10:12.578Z",
    "dateReserved": "2024-12-19T18:39:53.612Z",
    "dateUpdated": "2024-12-24T16:32:35.731Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2024-56334\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-12-24T16:32:16.418664Z\"}}}], \"references\": [{\"url\": \"https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m\", \"tags\": [\"exploit\"]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-12-24T16:32:30.447Z\"}}], \"cna\": {\"title\": \"Command injection vulnerability in getWindowsIEEE8021x (SSID) function in systeminformation\", \"source\": {\"advisory\": \"GHSA-cvv5-9h9w-qp2m\", \"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.8, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"REQUIRED\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}], \"affected\": [{\"vendor\": \"sebhildebrandt\", \"product\": \"systeminformation\", \"versions\": [{\"status\": \"affected\", \"version\": \"\u003c 5.23.7\"}]}], \"references\": [{\"url\": \"https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m\", \"name\": \"https://github.com/sebhildebrandt/systeminformation/security/advisories/GHSA-cvv5-9h9w-qp2m\", \"tags\": [\"x_refsource_CONFIRM\"]}, {\"url\": \"https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41\", \"name\": \"https://github.com/sebhildebrandt/systeminformation/commit/f7af0a67b78e7894335a6cad510566a25e06ae41\", \"tags\": [\"x_refsource_MISC\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"systeminformation is a System and OS information library for node.js. In affected versions SSIDs are not sanitized when before they are passed as a parameter to cmd.exe in the `getWindowsIEEE8021x` function. This means that malicious content in the SSID can be executed as OS commands. This vulnerability may enable an attacker, depending on how the package is used, to perform remote code execution or local privilege escalation. This issue has been addressed in version 5.23.7 and all users are advised to upgrade. There are no known workarounds for this vulnerability.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-94\", \"description\": \"CWE-94: Improper Control of Generation of Code (\u0027Code Injection\u0027)\"}]}], \"providerMetadata\": {\"orgId\": \"a0819718-46f1-4df5-94e2-005712e83aaa\", \"shortName\": \"GitHub_M\", \"dateUpdated\": \"2024-12-20T20:10:12.578Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2024-56334\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-12-24T16:32:35.731Z\", \"dateReserved\": \"2024-12-19T18:39:53.612Z\", \"assignerOrgId\": \"a0819718-46f1-4df5-94e2-005712e83aaa\", \"datePublished\": \"2024-12-20T20:10:12.578Z\", \"assignerShortName\": \"GitHub_M\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…