CVE-2025-0355 (GCVE-0-2025-0355)
Vulnerability from cvelistv5 – Published: 2025-01-15 07:23 – Updated: 2025-01-21 03:34
VLAI?
Summary
Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network.
Severity ?
7.5 (High)
CWE
- CWE-306 - Missing Authentication for Critical Function
Assigner
References
Impacted products
| Vendor | Product | Version | ||||||||||||||||||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| NEC Corporation | WG2600HS |
Affected:
Ver.1.7.2 and earlier
|
||||||||||||||||||||||||||||||||||||||||||
|
||||||||||||||||||||||||||||||||||||||||||||
Credits
Takayuki Sasaki and Katsunari Yoshioka of Yokohama National University.
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-0355",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-01-15T15:01:29.278695Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-01-15T15:01:48.659Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "WG2600HS",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.1.7.2 and earlier"
}
]
},
{
"defaultStatus": "unknown",
"product": "WF1200CR",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.1.6.0 and earlier"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG1200CR",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.1.5.0 and earlier"
}
]
},
{
"defaultStatus": "unknown",
"product": "GB1200PE",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.1.3.0 and earlier"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG2600HP4",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.1.4.2 and earlier"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG2600HM4",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.1.4.2 and earlier"
}
]
},
{
"defaultStatus": "unknown",
"product": "WG2600HS2",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.1.3.2 and earlier"
}
]
},
{
"defaultStatus": "unknown",
"product": "WX3000HP",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.2.4.2 and earlier"
}
]
},
{
"defaultStatus": "unknown",
"product": "WX4200D5",
"vendor": "NEC Corporation",
"versions": [
{
"status": "affected",
"version": "Ver.1.2.4 and earlier"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"user": "00000000-0000-4000-9000-000000000000",
"value": "Takayuki Sasaki and Katsunari Yoshioka of Yokohama National University."
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network."
}
],
"value": "Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network."
}
],
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-306",
"description": "CWE-306: Missing Authentication for Critical Function",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-01-21T03:34:13.440Z",
"orgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"shortName": "NEC"
},
"references": [
{
"url": "https://jpn.nec.com/security-info/secinfo/nv25-003_en.html"
}
],
"source": {
"discovery": "EXTERNAL"
},
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "f2760a35-e0d8-4637-ac4c-cc1a2de3e282",
"assignerShortName": "NEC",
"cveId": "CVE-2025-0355",
"datePublished": "2025-01-15T07:23:39.481Z",
"dateReserved": "2025-01-09T06:20:49.647Z",
"dateUpdated": "2025-01-21T03:34:13.440Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-0355\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-01-15T15:01:29.278695Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-01-15T15:01:42.017Z\"}}], \"cna\": {\"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"user\": \"00000000-0000-4000-9000-000000000000\", \"value\": \"Takayuki Sasaki and Katsunari Yoshioka of Yokohama National University.\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 7.5, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"NEC Corporation\", \"product\": \"WG2600HS\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.1.7.2 and earlier\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"NEC Corporation\", \"product\": \"WF1200CR\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.1.6.0 and earlier\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"NEC Corporation\", \"product\": \"WG1200CR\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.1.5.0 and earlier\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"NEC Corporation\", \"product\": \"GB1200PE\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.1.3.0 and earlier\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"NEC Corporation\", \"product\": \"WG2600HP4\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.1.4.2 and earlier\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"NEC Corporation\", \"product\": \"WG2600HM4\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.1.4.2 and earlier\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"NEC Corporation\", \"product\": \"WG2600HS2\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.1.3.2 and earlier\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"NEC Corporation\", \"product\": \"WX3000HP\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.2.4.2 and earlier\"}], \"defaultStatus\": \"unknown\"}, {\"vendor\": \"NEC Corporation\", \"product\": \"WX4200D5\", \"versions\": [{\"status\": \"affected\", \"version\": \"Ver.1.2.4 and earlier\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://jpn.nec.com/security-info/secinfo/nv25-003_en.html\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Missing Authentication for Critical Function vulnerability in NEC Corporation Aterm WG2600HS Ver.1.7.2 and earlier, WF1200CRS Ver.1.6.0 and earlier, WG1200CRS Ver.1.5.0 and earlier, GB1200PE Ver.1.3.0 and earlier, WG2600HP4 Ver.1.4.2 and earlier, WG2600HM4 Ver.1.4.2 and earlier, WG2600HS2 Ver.1.3.2 and earlier, WX3000HP Ver.2.4.2 and earlier and WX4200D5 Ver.1.2.4 and earlier allows a attacker to get a Wi-Fi password via the network.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-306\", \"description\": \"CWE-306: Missing Authentication for Critical Function\"}]}], \"providerMetadata\": {\"orgId\": \"f2760a35-e0d8-4637-ac4c-cc1a2de3e282\", \"shortName\": \"NEC\", \"dateUpdated\": \"2025-01-21T03:34:13.440Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-0355\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-01-21T03:34:13.440Z\", \"dateReserved\": \"2025-01-09T06:20:49.647Z\", \"assignerOrgId\": \"f2760a35-e0d8-4637-ac4c-cc1a2de3e282\", \"datePublished\": \"2025-01-15T07:23:39.481Z\", \"assignerShortName\": \"NEC\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…